Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"Peripheral oxygen saturation (SpO2)"”
-
Diferentes frações inspiradas de oxigênio e hiperinsuflação mecânica na aspiração endotraqueal aberta : impacto na oxigenação e ventilação pulmonar
… little evidence about the impact of the use of oxygen concentrations below 100% and the expiratory pressure-zero end expiratory pressure (PEEP-ZEEP) technique at increasing oxygenation and maintaining adequate ventilation during the OCES. In addition studies were not found concerning need or not …
-
Síndrome hepatopulmonar em crianças e adolescentes
… range [IQR]: 4.7–10.8). Partial arterial oxygen pressure (PaO2) of asymptomatic patients (44.4%) was higher than that of symptomatic patients (p<0.0001). Peripheral oxygen saturation (SpO2) was ≥96% in eight patients, seven of whom had PaO2 of <70 mmHg. The hemoglobin levels were elevated …
-
AI-based analysis of cerebral oxygenation in preterm and term infants
… injuries resulting from inadequate cerebral oxygenation, posing significant risks to their long-term neurodevelopment. Near-infrared spectroscopy (NIRS) is a non-invasive technology capable of monitoring regional cerebral oxygen saturation (rcSO2) and detecting cerebral desaturation events in …
-
Influence of exercise modality and modality-specific training on endurance exercise performance in hypoxia
… training or test modality (p=0.138). In rowers, peripheral oxygen saturation (SpO2) was lower at the end of rowing compared to cycling time trials (78±1 vs. 83±1%, p=0.002), and lower than that of cyclists at the end of rowing time trials (78±1 vs. 83±1%, p<0.001). DISCUSSION: Hypoxia-mediated …
-
Biomedical signal processing and inference in wearable sensing applications
… signals such as electrocardiogram (ECG), peripheral oxygen saturation (SpO2), blood pressure, airflow, etc. With the availability of these wearable sensors and powerful smartphones, it is now possible to build a smart health monitoring system that can continuously monitor and track a …
-
Validation of a micro-controller for oxygen control in the NICU
… is required for ventilation. With this, the peripheral oxygen saturation (SpO2) of the neonates admitted into the Neonatal Intensive Care Unit (NICU), requires nurses to adjust the fraction of inspired oxygen (FiO2) that the blend valve is supplying. The desired range of the SpO2 is 88 …
-
Brain Hypometabolism and Seizures: The Dynamics of Hypoxia and Hypoglycemia in Brain Energy Homeostasis
… of a poor prognosis. Thus, identifying how low oxygen and/or low glucose contribute to the generation of seizures may unveil mechanisms related to epileptogenesis, as well as provide a therapeutic target. Often, an imbalance in excitatory and inhibitory neurotransmission is associated with …
-
Carbon Dioxide Pneumoperitoneum and Laparoscopic Ovariectomy in the Domestic Rabbit (Oryctolagus cuniculus)
… PaO2); peak inspiratory pressure (PIP); and peripheral oxygen saturation (SpO2). Heart rate, SpO2, and ABP were unaffected by IAP. For PaO2, an interaction effect was seen between IAP and pressure sequence. PaCO2 increased at 8 mm Hg, and ETCO2 and PIP were greater with each IAP. IAP …
-
Efeito agudo da técnica de compressão lenta na modulação autonômica cardíaca de recém nascidos prematuros: um estudo quase experimental
… in resting heart rate (p = 0.0001) and increased peripheral oxygen saturation (SpO2) (p = 0.019). The LST performed with respect to signs of pain and discomfort caused, in an acute way, the increase in the parasympathetic modulation and the global variability, which translates into the improvement …
-
Impacto da reabilitação cardiorrespiratória precoce e da CPAP no pós-operatório de cirurgia de revascularização do miocárdio
… breathing pattern (BP), dyspnea sensation and peripheral oxygen saturation (SpO2) during the first day of ambulation in post-CABG. Twenty-seven patients were randomized to the control group-CG (ambulation in spontaneous breathing) (n = 14) or to CPAP group-CPG (ambulation associated to CPAP …
-
Predicting the Clinical Actionability of SpO2 Alarms in Intensive Care Medicine: Development of Explainable Machine Learning Models on Multimodal Clinical Data
… that can predict the clinical actionability of peripheral oxygen saturation (SpO2) alarms using multimodal clinical data, and 2) provide detailed insights into the relationship between clinical data and the model’s predictions. Methods: A retrospective cohort study was conducted using an …
-
Respostas fisiológicas do teste de caminhada incremental e de resistência em indivíduos com DPOC: uma revisão sistemática e metanálise
… test 1; 134 ± 19 mmHg x 149 ± 18 mmHg - test 2), Peripheral Oxygen Saturation (SpO2) (95,1±1,8% x 86,5±4,8%), (95,6±1,6 x 90,7±5.2%), (95,7± 1,8% x 92,4± 6% - teste 1; 95,1± 1,9% x 91,8± 6% - teste 2) and dyspnea (1.1±0.9 x 4,6±2,1 - test 1; 1,2±1,2 x 5,1±2,2 - test 2). The Distance Walked (DW) …
-
Comparação do uso de sistemas de aspiração aberto e fechado em récem-nascidos prematuros com peso abaixo de 1250 gramas
… 1250 grams in relation to the occurrence of oxygen desaturation and bradycardia before, during and after the suctioning procedure, during the first 72 hours of life. A randomized controlled trial was performed with a sample of 128 newborns, with gestational age 32 weeks, weight under 1250 g, …
-
Dessaturação de oxigênio durante a simulação de atividades de vida diária em pacientes após alta hospitalar pela COVID-19
… studies that evaluated the presence of a drop in peripheral oxygen saturation (SpO2) during the simulation of an ADL circuit in patients after COVID-19 are still incipient. Objectives: To verify by telemonitoring the presence of oxygen desaturation during the simulation of an activity of daily …
-
Avaliação da modulação dos níveis de hemoglobina fetal em crianças com anemia falciforme triadas pelo Programa de Triagem Neonatal de Minas Gerais e acompanhadas no Hemocentro de Belo Horizonte da Fundação Hemominas
… Hb F (p=0.001), total Hb (p ~ 0.001), and peripheral oxygen saturation (SpO2) (p=0.001 and 0.004, respectively). These polymorphisms were also associated with decreased reticulocyte counts (p=0.001). The rs9494145 polymorphism was significantly associated with increased Hb F (p = 0.006), …
-
Respostas fisiológicas, adaptações posturais e aspectos qualitativos do teste de avd-glittre sem mochila em indivíduos com doença pulmonar obstrutiva crônica
… that simulates the weight of supplementary oxygen equipment that can be changed for the weight, if necessary, without changing the test. However, it is not common for individuals with COPD carrying oxygen equipment in backpacks. In addition, these individuals present increased risk of falls …
-
Automated Home Oxygen Therapy through Closed-loop Control of Inhaled Oxygen Concentration
… cause of morbidity and mortality. Long-Term Oxygen Therapy (LTOT) is an established treatment in COPD patients with hypoxemia. LTOT is typically administered via continuous flow oxygen delivery with fixed flow rates prescribed by physicians. However, current LTOT approaches fail to consider …
-
Efeitos Fisiológicos da Ventilação por Peça Bucal, Recrutamento do Volume Pulmonar e Tosse Mecanicamente Assistida Medidos pela Tomografia de Impedância Elétrica em Pacientes Neuromusculares com Insuficiência Respiratória Severa.
… MI-E. Demographic data, respiratory rate (RR), peripheral oxygen saturation (SpO2) transcutaneous Pressure of Carbon Dioxide (PtcCO₂), impedance ventilation variation (TVz), TVz at two different times (Delta TVz), and End-Expiratory Lung Volume variation (EELz) were analyzed during all …
-
Efeitos Fisiológicos da Cânula Nasal de Alto Fluxo Medidos pela Tomografia de Impedância Elétrica na Doença Pulmonar Intersticial Crónica Grave
… and, eventually, respiratory failure. Oxygen therapy using a high-flow nasal cannula (HFNC) has well-recognized benefits in improving oxygen deficiency, while normalizing respiratory rate and reducing inspiratory effort, with additional benefits in humidifying the airways when compared …
-
Διερεύνηση της συνδυαστικής οξείας επίδρασης πρωτοκόλλων διαλείπουσας υποξίας -νορμοξίας και άσκησης σε βιοχημικούς δείκτες
… was utilized to monitor the heart rate (HR) and oxygen saturation (SpO2) during the IHNT. Venous blood samples were taken at five time points: baseline, before the trial, immediately after, one hour later, and three hours later, while an additional blood draw was added at the end of the IHNT and …
Page 1 of 2