Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Peristaltic micropump"”.

  1. MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP

    … is that of designing and developing a micropump for on-chip applications that have requirements for simultaneous high differential pressures and high flow rates, particularly for gas flow applications. In the literature, there are designs that provide high differential pressures at low …

    oklahoma-thes Repository record for MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP (opens in a new tab)

  2. MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP

    … is that of designing and developing a micropump for on-chip applications that have requirements for simultaneous high differential pressures and high flow rates, particularly for gas flow applications. In the literature, there are designs that provide high differential pressures at low …

    oklahoma-thes Repository record for MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP (opens in a new tab)

  3. Fabrication and characterization of a peristaltic micropump for use in medical drug delivery systems

    <p>A second-generation design micropump was fabricated and tested. The overall size of the micropump is 70 mm x 35 mm x 1 mm. The design of the micropump incorporates three chambers (12 mm in diameter, 180 [Mu]m deep) with 50 [Mu]m thick membranes, inlet and outlet valves, and flow channels (2 mm x …

    iastate Repository record for Fabrication and characterization of a peristaltic micropump for use in medical drug delivery systems (opens in a new tab)

  4. Novel two-stage peristaltic micropump optimized for automated drug delivery and integration into polymer microfluidic systems

    … <br>The core of the device is a novel two-stage peristaltic micropump. It features a backpressure independent volumetric dosing capability, such that a stable flow rate is ensured up to a backpressure of 30 kPa. This highly valuable feature is based on a new serial arrangement of two active …

    freiburg-diss Repository record for Novel two-stage peristaltic micropump optimized for automated drug delivery and integration into polymer microfluidic systems (opens in a new tab)

  5. DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS

    … work to achieve specific flow rate through a peristaltic micropump. A micropump consisting of four pneumatically actuated nozzle/diffuser shaped moving actuators on the sidewalls is considered for numerical study. These actuators are used to create pressure difference in the four pump …

    vcu Repository record for DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS (opens in a new tab)

  6. Cochlear Micropump Drug Delivery System: A noninvasive technique for murine intracochlear drug delivery

    … improved a miniaturized implantable and scalable peristaltic micropump that provides programmable and accurate drug delivery for inner ear applications. Borkholder Labs used a non-invasive micro-CT imaging technique to create a 3-D atlas of the mouse cochlea to determine measurements for transport …

    rit Repository record for Cochlear Micropump Drug Delivery System: A noninvasive technique for murine intracochlear drug delivery (opens in a new tab)

  7. Fabrication and characterization of a polydimethylsiloxane microfluidic pump for direct-sampling neuroscience experiments, with in-line capillary electrophoresis - laser-induced fluorescence chemical analysis

    A polydimethylsiloxane (PDMS) peristaltic micropump was designed, fabricated, and characterized, for intended use within rodent brain direct-sampling neuroscience experiments, with capillary electrophoresis - laser-induced fluorescence (CE-LIF) chemical analysis. The micropump was fabricated …

    umn Repository record for Fabrication and characterization of a polydimethylsiloxane microfluidic pump for direct-sampling neuroscience experiments, with in-line capillary electrophoresis - laser-induced fluorescence chemical analysis (opens in a new tab)

  8. A Novel Magnetorheological Pump Concept for Insulin Delivery

    … solution, we propose a magnetorheological peristaltic micropump to offer a compact, lightweight, portable, wirelessly controllable, durable, and low-power insulin delivery system. This study introduces a magnetic actuation mechanism for a micro-fluidic pump with a flap valve. A …

    gsu Repository record for A Novel Magnetorheological Pump Concept for Insulin Delivery (opens in a new tab)

  9. Droplet microfluidics for continuous chemical monitoring

    … volumes, which are defined by the design of a peristaltic micropump. Gareth Evans Importantly, sequences of droplets with controlled composition can be hardcoded into the pump, allowing chemical operations such as titrations and dilutions to be easily designed into the system, as well as …

    soton Download PDF for Droplet microfluidics for continuous chemical monitoring (opens in a new tab)

  10. Implantable Microsystem Technologies For Nanoliter-Resolution Inner Ear Drug Delivery

    … microsystem consisted of a thermal phase-change peristaltic micropump with wireless control and a refillable reservoir. The micropump is fabricated around a catheter microtubing (250 μm OD, 125 μm ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic …

    rit Repository record for Implantable Microsystem Technologies For Nanoliter-Resolution Inner Ear Drug Delivery (opens in a new tab)

  11. Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique

    … (GC) system. In a microfluidic system, the micropump is an essential component as an actuation sources to provide the driving force to mobilize fluids (liquid and gas) in a system. In this dissertation, development of an electrostatic valve-less peristaltic micropump for gas pumping is …

    uiuc Repository record for Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique (opens in a new tab)

  12. Droplet microfluidics based platform technology for continuous chemical sensing

    … method. The platform incorporates a phased peristaltic micropump and microfluidic chip for droplet generation, a pair of ‘electromagnetic tweezers’ for manipulation of magnetic beads and a spectrophotometer for colorimetric detection. This platform automates the entire process from sample …

    soton Download PDF for Droplet microfluidics based platform technology for continuous chemical sensing (opens in a new tab)