Results 1 to 5 of 5 for “"Phakometry"”

  1. Anterior Segment Optical Coherence Tomography-Based Phakometry Measurements in Children

    … using AS-OCT technology. METHODS: An ASOCT phakometry protocol was compared to video-based phakometry data on a sample of 42 children. RESULTS: AS-OCT phakometry demonstrated poor 95% limits of agreement (LOA) and significant magnitude bias, yielding excessively flat radii when used to …

    ohiolink Repository record for Anterior Segment Optical Coherence Tomography-Based Phakometry Measurements in Children (opens in a new tab)

  2. Compensated vs. Uncompensated Elongation during Myopia Progression: Results from the CLEERE and BLINK Studies

    … the location of H’ requires data from phakometry, a technique not utilized by most myopia control clinical trials. One of the purposes of this analysis is to develop a model for estimating the location of H’ using readily available biometric data. The other purpose of this analysis is …

    ohiolink Repository record for Compensated vs. Uncompensated Elongation during Myopia Progression: Results from the CLEERE and BLINK Studies (opens in a new tab)

  3. Refractive error shift with continuous use (Rescu) lenses

    … axial length, anterior chamber depth and phakometry. A hyperopic shift of 0.40 diopters was observed in previous myopic low-Dk extended wear hydrogel contact lens users after 3-months of continuous wear of a silicone hydrogel contact lens. Hyperopic shifts are predicted in those subjects …

    ohiolink Repository record for Refractive error shift with continuous use (Rescu) lenses (opens in a new tab)

  4. Purkinje images for optical assessment of lenticular surfaces

    … in the accuracy and repeatability of comparison phakometry results. Schematic eye models were set up for each subject and the anterior lens radius of curvature and conic constant were optimized to match the collected Purkinje image height data. The mean conic constant estimate from optimization …

    arizona-thes Repository record for Purkinje images for optical assessment of lenticular surfaces (opens in a new tab)

  5. Echographie oculaire transcornéenne par sonde linéaire multi-éléments haute-fréquence : étude et correction des effets aberrateurs du cristallin dans la reconstruction d'image en mode-B

    Milieu où les ultrasons se propagent environ 10% plus rapidement qu’au sein des tissus environnants, le cristallin est connu pour être la source majeure d’aberrations de phase du milieu oculaire. De fait, l’échographie ophtalmique trans cornéenne est affectée par ses effets qui se manifestent sur …

    star-france Repository record for Echographie oculaire transcornéenne par sonde linéaire multi-éléments haute-fréquence : étude et correction des effets aberrateurs du cristallin dans la reconstruction d'image en mode-B (opens in a new tab)