Phantom design to enable harmonisation of quantitative PET imaging for lung disease
… of a modified commercially available thorax phantom on clinical PET-CT scanners. Novel physical phantoms were then designed, and refined, to better approximate diseased lung density and structure, and to simplify parameter determination and validation. The designed phantoms comply with the …
-
Review of ultrasound probe calibration techniques for 3D ultrasound
… technologies, ultrasound image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give …
-
The Use of 3D-Printed Phantoms For Evaluating CT Image Quality
… has the potential to create a paradigm shift in phantom design from simple geometrical objects to more sophisticated structures that incorporate anatomical features. Phantoms are used as surrogates for humans when evaluating the performance of CT imaging systems, but traditional molding …
-
Dosimetric Verification of Respiratory-Gated Radiation Therapy using a Dynamic Phantom for Commissioning the Varian Real-Time Position Management System
… goal of this project is to construct a motorized phantom capable of reproducing the motion a tumor undergoes during respiration in order to commission the Varian RPM (Real-Time Position Management) System package on a TrueBeam linear accelerator. Measurements will be made to verify that the …
-
Novel Pulsatile Phantoms in Photoplethysmography
… (PPG) with the development of novel pulsatile phantoms, primarily through the innovative application of a continuous dip-coating vessel production. This approach achieved vessels with median wall thickness of 60 μm, surpassing commercial solutions in replicating human vascular structures. The …
-
Design and Evaluation of a Tunable-Stiffness Phantom
… to clinical practice, yet existing training phantoms often lack tunable stiffness and realistic tactile feedback. This thesis addresses these challenges by developing a modular palpation phantom that combines porous silicone sponges with granular jamming nodules, creating a bioinspired …
-
Development of Patient Based 3D Printed Cardiac Mitral Valve Phantoms
… simulation. We propose to develop a method to design, 3D print, and post process a mitral valve phantom with all subvalvular structures embedded inside a left heart cardiac phantom. To achieve this, we needed to develop new approaches, which will address the current challenges associated with …
-
Investigation of the potential effects of bone turnover on x-ray fluorescence measurements of bone lead in young women
… artifact. Using 3D printing techniques, a phantom design was created that emulates cortical porosity at structural sizes of 300 microns. A calibration set of lead-doped cortical porosity phantoms were created and compared with past bone lead phantoms, there was no statistically significant …
-
Monte Carlo techniques for electron radiotherapy
… neutrons, scattered electrons from the phantom, dependence on the measuring device, the choice of the effective point of measurements and other parameters could be responsible for this mismatch. The mismatch becomes much smaller as the beam energy increases. On the other hand a slight …
-
A phantom based evaluation on the effects of patient breathing motion on Stereotactic Body Radiotherapy treatment volumes
Aim: The aim of the study was to design an upper body phantom to mimic the movement of the lesion inside the lungs during a breathing cycle. Phantom design included an assessment of the motion observed for lung lesions, identification of suitable phantom materials as well as design of a motorized …
-
EXPLOITATION OF THE IMAGE CHARACTERISTICS OF A LOCALIZED TRANSILLUMINATION SYSTEM UTILIZING MOLECULAR CONTRAST AGENTS AND POLARIMETRY
<p>This research study purpose is to design an optical transillumination based system and explore the potential of imaging enhancement, utilizing various contrast agents and polarimetry. This novel design can be used to study the polarimetric image characteristics of an optical phantom which …
-
Multi-Wavelength in vivo Photon Absorption Remote Sensing: Towards Non-Contact Label-Free Functional Vascular Imaging
… by the development of techniques for in-vitro phantom studies. A blood oxygenation and deoxygenation protocol is developed and tested, enabling the time-efficient and low-cost preparation of blood samples at various oxygenation levels. Additionally, a flow phantom is developed with a 50 …
-
Investigations in x-ray computed tomography polyacrylamide gel dosimetry
… Systems for irradiating and imaging gels are designed and tested and dose response reproducibility is established. Results indicate dramatic variation in CT dose response sensitivity and range with gel composition. A model is developed to describe gel density change with dose, revealing two …
-
Εφαρμογή και αξιολόγηση του προγράμματος διασφάλισης ποιότητας στους οδοντιατρικούς υπολογιστικούς τομογράφους κωνικής δέσμης, σύμφωνα με τις ευρωπαϊκές κατευθυντήριες οδηγίες
… this 4-year project a commercially available QA Phantom and Software were designed and developed and a QA protocol for dental CBCT units was devised. The objective measurements of the majority of imaging performance characteristics allows quantification of the factors affecting image quality, …
-
Ultrasound-Guided Mechatronic System for Targeted Delivery of Cell-Based Cancer Vaccine Immunotherapy in Preclinical Models
… to a LN subcapsular space. The device was redesigned from its original CT-guided edition, which used a remote centre of motion architecture, to be easily integrated onto a commercially available VisualSonics imaging rail system. Subtle modifications were made to ensure simple workflow that …
-
Development of a Three-Dimensional Image-Guided Needle Positioning System for Small Animal Interventions
… tomography (micro-CT) imaging was developed. A phantom was developed to calibrate the geometric accuracy of micro-CT scanners to a traceable standard of measurement. Use of the phantom ensures the geometric fidelity of micro-CT images for use in image-guided interventions or other demanding …
-
A LEFT VENTRICULAR MOTION PHANTOM FOR CARDIAC MAGNETIC RESONANCE IMAGING
… and rotation. The purpose of this study was to design and build a low-cost, non-ferromagnetic LV motion phantom, for use with cardiac magnetic resonance imaging (MRI), that is able to produce physiologically realistic LV wall thickening and rotation.</p><p>Cardiac MRI is continuously expanding …