Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Phantom Omni"”.

  1. The PHANTOM Omni as an under-actuated robot

    … common, low-cost haptic interface device is the PHANTOM Omni. This device has six degrees of freedom for positioning, allowing the user to position and orientate the device anywhere in its workspace. One downside to the PHANTOM is that it only has motors for controlling the position of the …

    iastate Repository record for The PHANTOM Omni as an under-actuated robot (opens in a new tab)

  2. A study of haptic interactions with an under actuated robot in three dimensions

    … applications. A popular haptic device is the PHANTOM Omni, a six degree of freedom (6 DOF) positioning manipulator with 3 DOF force feedback. To increase the usability of the class of under actuated devices that include the common PHANTOM Omni, an impedance requiring full 6 DOF force feedback …

    iastate Repository record for A study of haptic interactions with an under actuated robot in three dimensions (opens in a new tab)

  3. Interaktivní manipulace s 3D objekty se silovou zpětnou vazbou

    … diplomové práci zastoupena zařízením SensAble Phantom Omni a souvisejícím toolkitem OpenHaptics. Čtenář je v úvodu seznámen s matematickými základy manipulace a s historií i současností haptických technologií. Následuje představení toolkitu OpenHaptics a především popis haptických knihoven …

    brno-tech Repository record for Interaktivní manipulace s 3D objekty se silovou zpětnou vazbou (opens in a new tab)

  4. A concept virtual harp with physical string vibrations using augmented reality for therapy

    … and haptic during interaction using a Sensable Phantom Omni haptic device and immersion in a portable augmented reality-based system using a video see-through head mounted display. Modeled as a realistic harp, the virtual harp uses realistic harp string vibrations modeled from Fourier analysis …

    iastate Repository record for A concept virtual harp with physical string vibrations using augmented reality for therapy (opens in a new tab)

  5. Towards the development of a mixed reality haptic temporal bone surgical simulation

    … manipulandum?" Three cases were compared: a Phantom Omni®, a standard HD2 and a modified HD2 with attached drill. Expert surgeons rated the standard HD2 and Phantom Omni equivalently whilst preferring the modified HD2 with attached drill. Though the modified HD2 scored higher in all …

    manitoba Repository record for Towards the development of a mixed reality haptic temporal bone surgical simulation (opens in a new tab)

  6. Design and prototyping of a pneumatically enabled haptic device

    … lbf (8.75 N) (in orthogonal position) while the PHANTOM Omni, commercial available haptic device similar to the developed device in terms of weight and size, has 0.75 lbf (3.3 N) maximum force capability.

    manitoba Repository record for Design and prototyping of a pneumatically enabled haptic device (opens in a new tab)

  7. Haptic sąsajos panaudojimas vartotojų įgūdžių įvertinimui /

    … 7 complex virtual 3D objects and haptic device Phantom Omni was used to indentify shape of the objects. Work contains 50 pages without extras. There are 16 pictures, 10 diagrams, 8 tables, 26 bibliographical entries and 5 extras.

    vilnius Repository record for Haptic sąsajos panaudojimas vartotojų įgūdžių įvertinimui / (opens in a new tab)

  8. Proposal for a real-time testing platform applied to tactile e-commerce

    … latency connection, and a slave device (virtual Phantom Omni manipulator). Through vibratory feedback, the platform enables interaction with virtual or remote elements, generating tactile sensations such as coarse roughness, fine roughness, smoothness, dripping, and softness. The obtained results …

    brazil-ufrn Repository record for Proposal for a real-time testing platform applied to tactile e-commerce (opens in a new tab)

  9. Figūrų atpažinimas jėgos grįžtamojo ryšio prietaisais /

    … using the device of power reversible connection “Phantom omni” and the program based on “Microsoft Visual C++”. 5 blindfolded people with no sight problems participated in the research. They were given 6 two – dimensional and three – dimensional figures. Having analyzed the data, it was concluded …

    vilnius Repository record for Figūrų atpažinimas jėgos grįžtamojo ryšio prietaisais / (opens in a new tab)

  10. Resilient Cooperative Control of Cyber-Physical Systems: Enhancing Robustness Against Significant Time Delays and Denial-of-Service Attacks

    … teleoperation strategies are tested using Phantom Omni devices and they show reduced chattering and better steady-state error convergence. A case study demonstrates how the proposed distributed algorithms effectively achieve consensus, even when some agents are disconnected from the network …

    ucf Repository record for Resilient Cooperative Control of Cyber-Physical Systems: Enhancing Robustness Against Significant Time Delays and Denial-of-Service Attacks (opens in a new tab)

  11. Adaptive and predictive time domain passivity control for haptic interfaces

    … validated through experiments conducted on the PHANToM OMNI haptic device in virtual environments. The results demonstrate the effectiveness of the approaches in reducing abrupt force changes and preserving transparency, thus enhancing the user's experience with haptic interfaces.

    ubc Repository record for Adaptive and predictive time domain passivity control for haptic interfaces (opens in a new tab) Download PDF for Adaptive and predictive time domain passivity control for haptic interfaces (opens in a new tab)

  12. Parameters design and the operation simulation of a pneumatic dispensing system for biomaterial 3D printing

    … the haptic feedback is presented by means of the Phantom Omni haptic interface. The virtual environment is developed using the Worldviz software. The haptic force feedback is calculated based on the spring-damper model and the proxy method. This system is verified using questionnaire survey to …

    manitoba Repository record for Parameters design and the operation simulation of a pneumatic dispensing system for biomaterial 3D printing (opens in a new tab)

  13. Haptic assessment of tissue stiffness in locating and identifying gynaecological cancer in human tissue

    … from the National Health Service. <br/><br/>The Phantom Omni, capable of 3D motion tracking, attached to a nano-17 force sensor, was used to capture real-time position data and force data. Uniaxial indentation palpation behaviour was used. The indentation depth was calculated using the …

    kings Repository record for Haptic assessment of tissue stiffness in locating and identifying gynaecological cancer in human tissue (opens in a new tab) Download PDF for Haptic assessment of tissue stiffness in locating and identifying gynaecological cancer in human tissue (opens in a new tab)

  14. Tissue Diagnosis Probe Based on Stiffness Measurement Using Vision and Force Sensing Modalities

    … was validatedthrough experiments on silicone phantomsand animal organs.Theresults showed that the probe could perform stiffness measurementsand localize tissue abnormalitieswhen indenting or sliding over the target surfaces. In order to investigate the mechanical properties of ex-vivo human …

    kings Repository record for Tissue Diagnosis Probe Based on Stiffness Measurement Using Vision and Force Sensing Modalities (opens in a new tab) Download PDF for Tissue Diagnosis Probe Based on Stiffness Measurement Using Vision and Force Sensing Modalities (opens in a new tab)

  15. Development and Design of a Compact Laparoendoscopic Single-Site Robotic Surgical System Integrating ROS2 Middleware

    … based on the motions of a Geomagic/Sensable Phantom Omni controller, and using velocity control to further adjust the positioning. Finally, rather than operating from multiple computers simultaneously, Robotic Operating System 2 (ROS2) middleware was implemented to allow for the simultaneous …

    hawaii Repository record for Development and Design of a Compact Laparoendoscopic Single-Site Robotic Surgical System Integrating ROS2 Middleware (opens in a new tab)

  16. Visuohaptic Simulation of a Borescope for Aircraft Engine Inspection

    … with two commonly available haptic devices, the Phantom Omni and the Novint Falcon, suggests that the improved camera model as well as probe contact feedback with the 3D engine model plays a significant role in the overall engine inspection process. Finally, we present results from a skill …

    clemson Repository record for Visuohaptic Simulation of a Borescope for Aircraft Engine Inspection (opens in a new tab)

  17. The Effects of Haptic Feedback on sEMG Input Performance

    Commodity electromyography (EMG) armbands are inexpensive tools that can be integrated into user interfaces. EMG involves measuring electrical activity associated with muscle movement and thus presents a novel input channel in human computer interaction. However, using EMG interfaces could present …

    washington Repository record for The Effects of Haptic Feedback on sEMG Input Performance (opens in a new tab)

  18. Investigating Visuo-Haptic Interaction Fidelity and Display Metaphors on Near-Field Fine Motor Selection and Manipulation Tasks in Virtual Reality

    … immersive head-tracked display, and it used the PHANToM OMNI haptic device to create a sensation of force feedback. This experiment was designed to determine if haptic feedback, stereoscopic rendering, and spatial distortion affected user performance by the metrics of speed, accuracy, and economy …

    clemson Repository record for Investigating Visuo-Haptic Interaction Fidelity and Display Metaphors on Near-Field Fine Motor Selection and Manipulation Tasks in Virtual Reality (opens in a new tab)