Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 130 for “"Phantom Studies"”

  1. Quantitative photoacoustic tomography: experimental phantom studies

    … by the unknown light fluence. Theoretical studies have succeeded in quantifying optical absorption and chromophore concentration by employing model-based inversions (MBI) that can deal with the non-linearity of the problem and the fluence-related distortion. However, experimental …

    ucl Repository record for Quantitative photoacoustic tomography: experimental phantom studies (opens in a new tab)

  2. Positron Emission Tomography Phantom Studies for Radiation Therapy Target Delineation

    … for cylindrical, spherical, cubic, and geodesic phantoms at various signal to background ratios (SBRs). Phantom studies revealed that as the SBR decreases the required threshold increases. Also, smaller phantom volumes required a larger threshold than larger phantom volumes. Phantom studies …

    wfu Repository record for Positron Emission Tomography Phantom Studies for Radiation Therapy Target Delineation (opens in a new tab)

  3. Methodology and phantom studies for the development and assessment of motion correction in simultaneous PET-MR

    … method for both pre-clinical and human studies. In particular, this study utilized prototype pre-clinical MR-compatible PET inserts. <br/>Following the phantom development and during the experimental procedures, various prototype simultaneous MR-compatible PET small-diameter scanners, in …

    kings Repository record for Methodology and phantom studies for the development and assessment of motion correction in simultaneous PET-MR (opens in a new tab)

  4. Towards clinical implementation of ultrafast combined kV-MV cone-beam CT for IGRT of lung tumors within breath-hold: evaluation of dosimetry and registration accuracy based on phantom studies

    … locations of an inhomogeneous thorax phantom were performed. Furthermore, the CT dose index (CTDI) was determined for future quality assurance purposes. A measured dose of 20.5mGE in the target region was comparable to the widely-used clinical imaging technique, whereas kV-MV spared …

    heid-diss Repository record for Towards clinical implementation of ultrafast combined kV-MV cone-beam CT for IGRT of lung tumors within breath-hold: evaluation of dosimetry and registration accuracy based on phantom studies (opens in a new tab)

  5. Magnetic Moment And Susceptibility Quantification In Mri: Additional Frequency Shifts From Materials And Background Phase Removal Using A Reference Phantom

    … to remove the unwanted background phase from phantom studies. Magnetic moments of straws filled by three different materials (gadolinium, ferritin, and nanoparticles) with four different concentrations of each material were subsequently quantified at 10 different echo times, with straws …

    wayne-thes Repository record for Magnetic Moment And Susceptibility Quantification In Mri: Additional Frequency Shifts From Materials And Background Phase Removal Using A Reference Phantom (opens in a new tab)

  6. Validation Platform for Ultrasound-Based Monitoring of Thermal Ablation

    … test-bed prototype was evaluated using phantom experiments to identify the shortcomings and limitations. In order to develop an improved validation platform, a simulator was implemented for evaluating registration methods as well as different line fiducial structures. New fiducial line …

    queens Repository record for Validation Platform for Ultrasound-Based Monitoring of Thermal Ablation (opens in a new tab)

  7. Fast and contrast-enhanced phase-sensitive magnetic resonance imaging

    … to provide ultra-fast image acquisitions. Phantom studies, performed on 1.5 T and 4.7 T MR scanners, demonstrated the developed generalized chemical-shift imaging technique could clearly separate breast silicone implant signals (4.0 ppm) from fat (3.5 ppm). The contrast-enhanced Dixon …

    tamu Repository record for Fast and contrast-enhanced phase-sensitive magnetic resonance imaging (opens in a new tab)

  8. Fluorescence enhanced optical tomography on breast phantoms with measurements using a gain modulated intensified CCD imaging system

    … optical imaging must be assessed in feasibility phantom studies. A novel intensified charge-coupled device (ICCD) imaging system has been developed to perform 3-D fluorescence tomographic imaging in the frequency-domain using near-infrared contrast agents. This study is unique since it (i) …

    tamu Repository record for Fluorescence enhanced optical tomography on breast phantoms with measurements using a gain modulated intensified CCD imaging system (opens in a new tab)

  9. Bioelectrical strategies for image-guided therapies

    … the method in numerical simulations and phantom studies. Due to the rapidity of arrhythmic origin localization, ISGA may prove a highly effective means of guiding the ablative therapy of hemodynamically-unstable VT. The second method, the Bioelectrical Image Guidance (BIG) Method, is a …

    mit Repository record for Bioelectrical strategies for image-guided therapies (opens in a new tab)

  10. Low Frequency Bio-Electrical Impedance Mammography and Dielectric Measurement

    … values of normal breast tissues. While previous studies have shown that this assumption is valid at high frequencies (50MHz-20GHz), less research efforts have been dedicated to ascertain the validity of such assumption at low frequencies (in silico and tissue mimicking phantom studies. Results of …

    uwo Repository record for Low Frequency Bio-Electrical Impedance Mammography and Dielectric Measurement (opens in a new tab)

  11. 3D orbital navigators for measurement of head motion in echo planar magnetic resonance imaging

    … tested by means of numerical simulation. The phantom studies involving controlled rotation and displacement of an inhomogeneous test object during an MRI acquisition established the technique's accuracy. In-vivo experiments showed that the navigator echoes can be used in measuring the gross …

    mcgill Repository record for 3D orbital navigators for measurement of head motion in echo planar magnetic resonance imaging (opens in a new tab)

  12. Combined Photoacoustic and Doppler Ultrasound Imaging for Tissue Oxygen Consumption Estimation

    … Doppler ultrasound. We aim to devise flow phantom experiments to validate the capabilities of our technique for MRO2 estimation, and further demonstrate the feasibility of cerebral MRO2 estimation in brain auto-regulation study in vivo in a pre-clinical animal model. Work conducted in this …

    alberta Repository record for Combined Photoacoustic and Doppler Ultrasound Imaging for Tissue Oxygen Consumption Estimation (opens in a new tab)

  13. Digital image enhancement algorithms for 2D ultrasound imaging systems

    … i.e., Laplacian pyramid. From simulation and phantom studies, an average gain of 1.55 dB and 1.34 dB in contrast-to-noise ratio (CNR) were obtained compared with recently-developed speckle reducing anisotropic diffusion (SRAD) and nonlinear coherent diffusion (NCD), respectively. The visual …

    nanyang Repository record for Digital image enhancement algorithms for 2D ultrasound imaging systems (opens in a new tab)

  14. Advancing optical coherence tomography: improving measurement accuracy and introducing novel sensing applications

    … measurement uncertainty from 1.5% to 0.7% in phantom studies, with further validation in-vivo on human skin. Second, a self-supervised deep learning framework was introduced to enhance system accuracy by improving axial resolution. Unlike traditional intensity-based methods, this approach …

    nanyang Repository record for Advancing optical coherence tomography: improving measurement accuracy and introducing novel sensing applications (opens in a new tab)

  15. Magnetic Resonance Elastography of the Brain: from Phantom to Mouse to Man

    … three kinds of MRE experiments, conducted in phantom: physical model), mouse, and man. Phantom studies provide a means to experimentally confirm the accuracy of MRE estimates of viscoelastic parameters in relatively simple materials and geometries. Studies in the mouse provide insight into the …

    wustl Repository record for Magnetic Resonance Elastography of the Brain: from Phantom to Mouse to Man (opens in a new tab)

  16. Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging

    … in PET/CT imaging. Computer simulations, phantom studies, as well as patient studies are conducted to test the performance of these proposed techniques and their results are shown in this thesis.

    rice Repository record for Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging (opens in a new tab)

  17. Optimisation of the digital radiographic imaging of suspected non-accidental injury.

    … the United Kingdom (UK) with suspected NAI. (iv) Phantom studies. Leeds TO. 10 and TO. 16 test objects were used to compare the relationship between film density, exposure parameters and visualisation of object details, (iv) Clinical study. Anteroposterior and lateral post mortem skull radiographs …

    ucl Repository record for Optimisation of the digital radiographic imaging of suspected non-accidental injury. (opens in a new tab)

  18. Analytical calculation of photon distributions in SPECT projections

    … those of Monte Carlo simulation and experimental phantom studies. It has been validated with respect to sources in both homogeneous and non-homogeneous media. Compared with a similar analytical technique, it offers a factor of 40-60 decrease in the calculation time for higher order Compton scatter …

    ubc Repository record for Analytical calculation of photon distributions in SPECT projections (opens in a new tab)

  19. Integration of nanodosimetric Ionization Detail in particle therapy treatment planning

    … database of nanodosimetric quantities. Phantom studies demonstrate that cluster dose can be computed with an accuracy comparable to conventional dose calculations. While predicted biological effects show the expected dependence on the biological system, the proposed framework provides a …

    heid-diss Repository record for Integration of nanodosimetric Ionization Detail in particle therapy treatment planning (opens in a new tab)

  20. Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System

    … coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and …

    arkansas Repository record for Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System (opens in a new tab)

Page 1 of 7