Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 37 for “"Phase Contrast Magnetic resonance imaging"”

  1. Numerical simulations for phase-contrast magnetic resonance imaging

    L'hémodynamique (la manière dont le sang coule) est aujourd'hui considérée par la communauté médicale comme un marqueur prépondérant dans l'apparition et dans l'évolution de certaines pathologies cardiovasculaires (formation d’un caillot sanguin, anévrisme, sténose...). Les récents progrès …

    star-france Repository record for Numerical simulations for phase-contrast magnetic resonance imaging (opens in a new tab)

  2. Characterizing single ventricle hemodynamics using phase contrast magnetic resonance imaging

    … operation. Despite significant development of phase contrast magnetic resonance imaging (PC MRI) for in vivo flow measurements, it is not routinely applied in children with single ventricle congenital heart disease. Limited technologies available for post-processing of PC MRI data has prevented …

    gatech Repository record for Characterizing single ventricle hemodynamics using phase contrast magnetic resonance imaging (opens in a new tab)

  3. Computational Modeling and Technique Assessment on Phase Contrast Magnetic Resonance Imaging

    osaka

  4. Bayesian Models for Practical Flow Imaging Using Phase Contrast Magnetic Resonance Imaging

    … million pixels are commonplace. The field of magnetic resonance imaging (MRI) isno different. In MRI, doctors push for higher spatial and temporal resolution images, withcurrent brain imaging having sub mm pixel resolution. However, acquisition time for MRIis proportional to the number of …

    ohiolink Repository record for Bayesian Models for Practical Flow Imaging Using Phase Contrast Magnetic Resonance Imaging (opens in a new tab)

  5. Rapid phase-contrast magnetic resonance imaging using spiral trajectories and parallel imaging

    Phase contrast (PC) MRI is a proven method of measuring blood flow in the clinical environment. Traditionally, PCMR data is acquired using cardiac gated Cartesian sequences. However, these sequences are time consuming and difficult to perform in patients with irregular heart rates. The work of my …

    ucl Repository record for Rapid phase-contrast magnetic resonance imaging using spiral trajectories and parallel imaging (opens in a new tab)

  6. Numerical And Experimental Study Of Three Imaging Advancements In Phase Contrast Magnetic Resonance Imaging

    … study aimed at the numerical simulation of three imaging options in phase contrast magnetic resonance (PC-MR), developed jointly at University of Alabama at Birmingham and Allegheny Research Institute. The three methods were: 1) Fragmented Regional Interpolation Segmentation for K-space (FRISK); …

    uab Repository record for Numerical And Experimental Study Of Three Imaging Advancements In Phase Contrast Magnetic Resonance Imaging (opens in a new tab)

  7. Intracranial fluids dynamics: a quantitative evaluation by means of phase-contrast magnetic resonance imaging

    … secuencias dinámicas de resonancia magnética en contraste de fase (RM-CF) con sincronismo cardíaco permiten cuantificar el flujo de LCR y de sangre durante un ciclo cardíaco. La medición de flujo mediante secuencias de RM-CF es precisa y reproducible siempre que se use un protocolo de adquisición …

    upv Repository record for Intracranial fluids dynamics: a quantitative evaluation by means of phase-contrast magnetic resonance imaging (opens in a new tab)

  8. MODELING OF PATIENT-SPECIFIC PERIAORTIC MECHANICS AND PULMONARY ARTERY HEMODYNAMICS BASED ON PHASE-CONTRAST MAGNETIC RESONANCE IMAGING SEQUENCES.

    … of clinical risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs. Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were …

    vcu Repository record for MODELING OF PATIENT-SPECIFIC PERIAORTIC MECHANICS AND PULMONARY ARTERY HEMODYNAMICS BASED ON PHASE-CONTRAST MAGNETIC RESONANCE IMAGING SEQUENCES. (opens in a new tab)

  9. A Novel Method to Assess Pulse Wave Velocity using Single Velocity Encoding in Phase Contrast Imaging

    … of pulse wave velocity (PWV) using conventional phase contrast magnetic resonance imaging (PC-MRI) is recognized as a standard technique to assess arterial stiffness by measuring the arrival times of blood velocity waveforms. Conventional PC-MRI requires the acquisition of two sets of complex …

    wfu Repository record for A Novel Method to Assess Pulse Wave Velocity using Single Velocity Encoding in Phase Contrast Imaging (opens in a new tab)

  10. Blood flow dynamics through a defective mechanical heart valve

    … were proposed using Doppler echocardiography and phase contrast magnetic resonance imaging, for an early detection of mechanical heart valve malfunction. Finally, the relation between the coherent structures downstream of the valve and the valve malfunction was shown and the significant impact of …

    concordia

  11. The Use of MRI for Sternocleidomastoid Muscle Volume Measurement and its Association with Internal Carotid Artery Velocity in a Healthy Cohort

    … carotid artery (ICA) blood flow velocity (BFV). Imaging of the SCMM was conducted using Phase-Contrast Magnetic Resonance Imaging (PC-MRI) and the ICA BFV was examined by Doppler Ultrasound (DU) of 34 healthy participants (19 females, 15 males). Significant sex differences were established in …

    york Repository record for The Use of MRI for Sternocleidomastoid Muscle Volume Measurement and its Association with Internal Carotid Artery Velocity in a Healthy Cohort (opens in a new tab)

  12. Non-invasive relative pressure estimation using 4D PC-MRI

    … information provided by Four Dimensional Phase-Contrast Magnetic Resonance Imaging, an existing finite element formulation to compute pressure differences is evaluated, illustrating its sensitivity to data when estimating viscous flows and exploring potential approaches to address this. A …

    kings Repository record for Non-invasive relative pressure estimation using 4D PC-MRI (opens in a new tab)

  13. An in vitro method for the error assessment of Phase Contrast Magnetic Resonance lmaging based velocity measurements and calculation of derived Wall Shear Stress

    … les acquisitions de vitesse obtenues par la Phase Contrast Magnetic Resonance Imaging (PC MRI) et le calcul du WSS dérivé. Pour ce faire, des profils de vitesse de référence ont été obtenus avec la Vélocimétrie Laser à effet Doppler (LDV) utilisés pour comparaison directe avec les résultats …

    star-france Repository record for An in vitro method for the error assessment of Phase Contrast Magnetic Resonance lmaging based velocity measurements and calculation of derived Wall Shear Stress (opens in a new tab)

  14. Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System

    … to pathologies of the cardiovascular system. Phase‐contrast Magnetic Resonance Imaging (MRI) provides a non‐invasive technique for the assessment of time‐resolved blood velocity vector fields within arbitrary imaging volumes. Besides velocity vector field information, parameters related to …

    kings Repository record for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab)

  15. Fetal Blood Flow Mapping with Magnetic Resonance Imaging

    Phase contrast magnetic resonance imaging (MRI) has the potential to assess fetal blood flow. However, it faces challenges such as the small size of fetal vessels, the high fetal heart rate, uncontrolled fetal motion, limited methods to measure the fetal heart rate and the considerable complexity …

    toronto-retro Repository record for Fetal Blood Flow Mapping with Magnetic Resonance Imaging (opens in a new tab)

  16. A study of Quantification of Aortic Compliance in Mice using Radial Acquisition Phase Contrast MRI

    … changes in blood flow velocity measured using Phase contrast Magnetic Resonance Imaging (MRI) can be used to quantify Pulse Wave Velocity (PWV) and Wall Shear Stress (WSS), well known indices of vessel compliance. A study was conducted to measure the PWV in the aortic arch in young healthy …

    ohiolink Repository record for A study of Quantification of Aortic Compliance in Mice using Radial Acquisition Phase Contrast MRI (opens in a new tab)

  17. 4D Flow Magnetic Resonance Imaging and Computational Fluid Dynamics for the Study of Complex Blood Flow Patterns in Carotid Webs

    … flow patterns associated with CaW, advanced imaging techniques such as three-dimensional, three-directional, ECG-gated, time-resolved, phase-contrast magnetic resonance imaging (4D flow MRI) as well as computational fluid dynamics (CFD) are employed in this study. First, the spatio-temporal …

    gatech Repository record for 4D Flow Magnetic Resonance Imaging and Computational Fluid Dynamics for the Study of Complex Blood Flow Patterns in Carotid Webs (opens in a new tab)

  18. In Vitro Fluid Dynamics of Stereolithographic Single Ventricle Congenital Heart Defects From In Vivo Magnetic Resonance Imaging

    … of single ventricle patients from in vivo magnetic resonance imaging (MRI) to examine the gamut of TCPC anatomies. From stereolithographic models of representative cases, pressure and flow data are used to quantify control volume power loss to measure overall efficiency. particle image …

    gatech Repository record for In Vitro Fluid Dynamics of Stereolithographic Single Ventricle Congenital Heart Defects From In Vivo Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 2