Showing 1 to 19 of 19 for “"Phase aberration"”.

  1. Phase Aberration Correction for Real-Time 3D Transcranial Ultrasound Imaging

    <p>Phase correction has the potential to increase the image quality of real-time 3D (RT3D) ultrasound, especially for transcranial ultrasound. Such improvement would increase the diagnostic utility of transcranial ultrasound, leading to improvements in stroke diagnosis, treatment, and monitoring. …

    duke Repository record for Phase Aberration Correction for Real-Time 3D Transcranial Ultrasound Imaging (opens in a new tab)

  2. Simplifying Interpretation of Ultrasound Imaging: Deep Learning Approaches for Phase Aberration Correction and Automatic Segmentation

    … on improving image quality by addressing the phase aberration effect, a primary contributor to the degradation of medical ultrasound images. Phase aberration arises from spatial variations in sound speed within heterogeneous media, introducing artifacts such as blurring and geometric …

    concordia Download PDF for Simplifying Interpretation of Ultrasound Imaging: Deep Learning Approaches for Phase Aberration Correction and Automatic Segmentation (opens in a new tab)

  3. Transcranial Adaptive Beamforming via Ultrasonic Phased Arrays and its Application to 3D Imaging of Certain Types of Head Injuries

    … method for ultrasonic imaging via small-aperture phased arrays through composite layered structures, such as human skull, is developed. If there is a scattering layer between the phased array and the imaged volume, acoustic phase aberration and wave refraction at undulating interfaces between the …

    toronto-retro Repository record for Transcranial Adaptive Beamforming via Ultrasonic Phased Arrays and its Application to 3D Imaging of Certain Types of Head Injuries (opens in a new tab)

  4. Methodologies for enhancing ultrasonic NDE of coarse-grained materials

    … in ultrasonic NDE of coarse-grained materials: phase aberration and backscattering noise.Phase aberration denotes that the wavefronts from elements of a phased array undergo phases shifts. A phase aberration correction approach based on microstructural characterisation and finite element …

    strathclyde Repository record for Methodologies for enhancing ultrasonic NDE of coarse-grained materials (opens in a new tab)

  5. Safety Considerations and Clinical Benefit Analysis for the Use of Elevated Acoustic Output in Diagnostic Ultrasound Imaging

    … in situ PRP by 20-48%, due primarily to phase aberration. For a medium transmit aperture (F/3), the MI accurately estimated the in situ PRP to within 8%. For a small transmit aperture (F/5), MI consistently underestimated the in situ PRP by 32-50%, with peak locations occurring 1-2 cm …

    duke Repository record for Safety Considerations and Clinical Benefit Analysis for the Use of Elevated Acoustic Output in Diagnostic Ultrasound Imaging (opens in a new tab)

  6. Liquid crystal spatial light modulators as computer controlled optical elements / (Marie-Therese) Thu-Lan Kelly.

    … and experimentally, and their performance as phase modulators tested in the two diverse applications of computer generated holography and phase aberration correction. Commercial liquid crystal panels from a video projector were used, chosen because of low cost, high resolution, computer …

    adelaide Repository record for Liquid crystal spatial light modulators as computer controlled optical elements / (Marie-Therese) Thu-Lan Kelly. (opens in a new tab)

  7. Coherent Digital Holographic Adaptive Optics

    … that gives direct numerical access to the phase of the optical field, thus allowing precise control and manipulation of the optical field. Incorporation of DH in an ophthalmic imaging system can lead to versatile imaging capabilities at substantially reduced complexity and cost of the …

    usf Repository record for Coherent Digital Holographic Adaptive Optics (opens in a new tab)

  8. Backscattering and attenuation during the propagation of ultrasonic waves in duplex titanium alloys

    … studies will be reported which show that the phase aberration contribution to attenuation does not remove energy from the propagating beam, and a physical picture is developed. A simple ray model which encompasses the ideas presented in the physical picture is used to predict attenuation for …

    iastate Repository record for Backscattering and attenuation during the propagation of ultrasonic waves in duplex titanium alloys (opens in a new tab)

  9. Subcarrier optical wireless communications in atmospheric turbulence

    … turbulence channel induces scintillation and phase aberration, which can result in significant performance degradation. The error rate performance of subcarrier OWC systems with lower order phase-shift keying (PSK) over the Gamma-Gamma turbulence channels is investigated using a direct …

    ubc Repository record for Subcarrier optical wireless communications in atmospheric turbulence (opens in a new tab) Download PDF for Subcarrier optical wireless communications in atmospheric turbulence (opens in a new tab)

  10. On the Development of High-frequency Phased Array Systems for Transcranial Ultrasound Delivery in Small Animals

    … can improve targeting specificity; however, the aberrations induced by rodent calvaria at megahertz frequencies severely distort the acoustic fields produced by single-element focused transducers. In this thesis, we present the design, fabrication, and characterization of high-frequency phased …

    toronto-retro Repository record for On the Development of High-frequency Phased Array Systems for Transcranial Ultrasound Delivery in Small Animals (opens in a new tab)

  11. Quantification of structural changes in cortical bone by estimating thickness, speed of sound and pore size distribution

    … the tibia. The first method is a refraction and phase aberration corrected multifocus (MF) imaging approach that measures Ct.Th and the compressional sound velocity traveling in the radial bone direction (Ct.ν11). The second method is a novel cortical backscatter (CortBS) method that assesses …

    fu-berlin Repository record for Quantification of structural changes in cortical bone by estimating thickness, speed of sound and pore size distribution (opens in a new tab)

  12. Acoustoelectric Imaging of Deep Brain Stimulation Currents

    … as the St. Jude’s Infinity. I then demonstrate a phase-aberration correction method that significantly restores the lateral focal resolution and pressures in transcranial ultrasound by performing time-reversal operations on an electrical target. Lastly, clinical implications and future directions …

    arizona-thes Repository record for Acoustoelectric Imaging of Deep Brain Stimulation Currents (opens in a new tab)

  13. Numerical methods for nonlinear wave propagation in ultrasound

    … PSF the primary source of degradation is phase aberration. Ultrasound images are created in silico and these beamformed images are compared to images obtained from convolution of the PSF with a scatterer field to demonstrate that a very large portion of the PSF must be used to accurately …

    duke Repository record for Numerical methods for nonlinear wave propagation in ultrasound (opens in a new tab)

  14. Spatial and Contrast Enhancement in Photoacoustic Imaging

    … affected by side lobes, clutter and phase aberration when the DAS beamfomer is used. All of these reduce the spatial resolution, SNR and contrast of the image. Researchers have used some adaptive beamforming techniques to reduce these effects. In this thesis, the filter delay multiply …

    whiterose Download PDF for Spatial and Contrast Enhancement in Photoacoustic Imaging (opens in a new tab)

  15. Improvement of image quality of transcranial Doppler ultrasound

    … This is because of several effects including phase aberration, variations in the speed of sound in the skull, scattering, the acoustic impedance mismatch, and absorption of the three-layer medium made up of soft tissues, the skull, and the brain. Secondly, there is also an energy loss because …

    ets-quebec Download PDF for Improvement of image quality of transcranial Doppler ultrasound (opens in a new tab)

  16. Machine Learning-Assisted Optimization Framework for Designing Transcranial Focused Ultrasound Transducers for Deep Brain Neuromodulation and Obesity-Related Preliminary Studies in Mice

    … attenuation, reflection, refraction, and phase aberration that can distort the focal region, shift the pressure maximum away from the intended target, and increase off-target acoustic exposure. These challenges are particularly important for hypothalamic neuromodulation, where the target …

    ttu Repository record for Machine Learning-Assisted Optimization Framework for Designing Transcranial Focused Ultrasound Transducers for Deep Brain Neuromodulation and Obesity-Related Preliminary Studies in Mice (opens in a new tab) Embargoed until 2027-08-01

  17. Ultrasound Catheter Transducers for Intracranial Brain Imaging and Therapy

    … the high ultrasound attenuation, reflection, and phase aberration resulting from the skull and its variable thickness. Dual-mode ultrasound transducers for image-guided therapy have also been investigated for several applications; in some instances, phased arrays are ideal, allowing control over …

    duke Repository record for Ultrasound Catheter Transducers for Intracranial Brain Imaging and Therapy (opens in a new tab)

  18. The Ultrasound Brain Helmet: Simultaneous Multi-transducer 3D Transcranial Ultrasound Imaging

    … it. Specifically, this dissertation discusses aberration and attenuation due to the skull as sources of image degradation and presents a prototype system for simultaneous 3D bilateral imaging via both temporal acoustic windows. This system uses custom sparse array transducers built on flexible …

    duke Repository record for The Ultrasound Brain Helmet: Simultaneous Multi-transducer 3D Transcranial Ultrasound Imaging (opens in a new tab)

  19. Efficient Spatial Coherence Estimation for Improved Endocardial Border Visualization in Real-Time

    … and subcutaneous fat layers, giving rise to phase aberration errors and acoustical clutter from near-field reverberation. In the event that two or more segments are inadequately visualized, the ASE recommends the use of contrast agents. Though contrast agents are effective, they are invasive …

    duke Repository record for Efficient Spatial Coherence Estimation for Improved Endocardial Border Visualization in Real-Time (opens in a new tab)