Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 695 for “"Phase-Contrast"”

  1. Coded Aperture Phase Contrast Tomosynthesis

    X-ray Phase Contrast (PC) Imaging has the potential to greatly improve radiography. Conventional radiography is based on the imaginary part of the refractive index, whereas PC imaging is based on the unit decrement of the real part, which can be up to 1000 times larger. This is particularly …

    ucl Repository record for Coded Aperture Phase Contrast Tomosynthesis (opens in a new tab)

  2. New implementations of phase-contrast imaging

    Phase-contrast imaging is a method of imaging widely used in biomedical research and applications. It is a label-free method that exploits intrinsic differences in the refractive index of different tissues to differentiate between biological structures under analysis. The basic principle of …

    bu Repository record for New implementations of phase-contrast imaging (opens in a new tab)

  3. Edge illumination x-ray phase contrast CT

    … modalities providing enhanced soft tissue contrast exists in a number of biomedical disciplines. X-ray phase contrast (PC) methods can provide a solution: contrast is driven by the refractive index decrement from unity (RID) rather than the absorption term, the former being much larger than …

    ucl Repository record for Edge illumination x-ray phase contrast CT (opens in a new tab)

  4. Motion tracking in phase-contrast microscopic images

    … The proposed methods have been tested on the phase-contrast microscopic videos provided by Garvan Institute of Medical Research. Quantitative and qualitative analysis presented in this thesis show that employing temporal information for both cell segmentation and mitosis detection does improve …

    unsw Repository record for Motion tracking in phase-contrast microscopic images (opens in a new tab)

  5. Spectral Phase Contrast Imaging and Phase Retrieval

    Phase-contrast X-ray imaging (PCI) can significantly improve the contrast of small and weakly-absorbing materials. This is because of the sensitivity of PCI measurements to changes in both the attenuation and phase of an X-ray wavefield due to interactions with matter. Yet, quantitative estimates …

    houston Repository record for Spectral Phase Contrast Imaging and Phase Retrieval (opens in a new tab)

  6. Phase Contrast Imaging of Laser-Induced Microcavitation

    … setup to image microcavitation develop with phase contrast microscopy. The goal of the numerical simulation is to accurately model the microcavitation process. The corresponding goal of the experimental setup is to identify additional features not visible in brightfield microscopy. The …

    tamu Repository record for Phase Contrast Imaging of Laser-Induced Microcavitation (opens in a new tab)

  7. Spectral speckle based X-ray phase contrast imaging

    L'imagerie par contraste de phase aux rayons X est une technique d'imagerie offrant un fort potentiel grâce à son contraste amélioré par rapport à la radiographie conventionnelle. Contrairement à l'atténuation, directement mesurable, la phase aux longueurs d'onde des rayons X n'est pas une grandeur …

    star-france Repository record for Spectral speckle based X-ray phase contrast imaging (opens in a new tab)

  8. Numerical simulations for phase-contrast magnetic resonance imaging

    L'hémodynamique (la manière dont le sang coule) est aujourd'hui considérée par la communauté médicale comme un marqueur prépondérant dans l'apparition et dans l'évolution de certaines pathologies cardiovasculaires (formation d’un caillot sanguin, anévrisme, sténose...). Les récents progrès …

    star-france Repository record for Numerical simulations for phase-contrast magnetic resonance imaging (opens in a new tab)

  9. Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping

    Phase-contrast MRI is used to assess functional flow parameters of the cardiovascular system. Long scan times of three-dimensional flow encoded MRI in particular have, however, hampered the acceptance of the method in a clinical routine setting. Furthermore, concerns have recently been raised about …

    kings Repository record for Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping (opens in a new tab)

  10. Phase contrast transmission electron microscopy using phase plates

    … of cells and polymers often leads to poor image contrast and poor transfer of information with a spatial frequency lower than around 2 nm. In addition, the information contained in the phase of the specimen exit wave is often lost due to an inability to directly record phase changes. Electron …

    utk-theses Repository record for Phase contrast transmission electron microscopy using phase plates (opens in a new tab)

  11. Asymmetric Illumination X-ray Differential Phase Contrast Imaging

    … we present a novel, low-cost approach to x-ray phase contrast imaging (XPCI). This method, which we term asymmetric illumination x-ray phase contrast imaging (AIXPCI), is compatible with a broadband tabletop x-ray source in a conventional laboratory setting and utilizes an angular filtration …

    duke Repository record for Asymmetric Illumination X-ray Differential Phase Contrast Imaging (opens in a new tab)

  12. X-ray phase-contrast imaging using near-field speckles

    In the last decades, X-ray phase-contrast imaging has proven to be a powerful method for unveiling the inner structure of samples and is capable of visualising even minute density differences. Recently, speckle-based imaging (SBI), the youngest X-ray phase-sensitive technique, has received great …

    ucl Repository record for X-ray phase-contrast imaging using near-field speckles (opens in a new tab)

  13. Multiscale neuroimaging using synchrotron X-ray phase-contrast tomography

    X-ray phase-contrast tomography (X-PCI-CT) is an emerging imaging technology in the field of biomedicine. This methodology represents an advancement compared to traditional absorption-based X-ray CT in that it can measure phase-shift-inducing X-ray refraction effects in addition to photon …

    lmu-germany Repository record for Multiscale neuroimaging using synchrotron X-ray phase-contrast tomography (opens in a new tab)

  14. X-ray Phase Contrast Tomography : Setup and Scintillator Development

    … on the micrometre scale. To improve the image contrast for small and low-density samples, it is possible to introduce a propagation distance between sample and detector to perform propagation-based phase contrast imaging (PB-PCI). This contrast mode relies on a sufficiently coherent …

    lund Repository record for X-ray Phase Contrast Tomography : Setup and Scintillator Development (opens in a new tab)

  15. Advances in Energy Sensitive X-ray Phase Contrast Measurements

    … This approach proposes that rotating a steep phase gradient in a predetermined sinusoidal pattern will remove additional sources of noise and bias and isolate the influence of refraction. (2) A robust simulation of this energy sensitive refractometer. This simulation is used to initially …

    duke Repository record for Advances in Energy Sensitive X-ray Phase Contrast Measurements (opens in a new tab)

  16. Fat Suppression and Segmentation in Phase-Contrast MRI Flow Measurements

    … tool. For instance, magnetic resonance (MR) phase contrast (PC) imaging holds great potential as a non-invasive diagnostic tool by measuring the blood flow in coronary arteries. Unfortunately, artifacts in the resultant images as well as current limitations of the PC technique have hindered …

    wfu Repository record for Fat Suppression and Segmentation in Phase-Contrast MRI Flow Measurements (opens in a new tab)

Page 1 of 35