Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 691 for “"Phasor"”

  1. Resistive Companion Dynamic Phasor Networks and Phasor to Time Domain Network Coupling

    The resistive companion form (RCF) is extended to phasor and dynamic phasor models. A phasor solver is implemented in the Virtual Test Bed (VTB) simulation environment. Several models targeting the VTB phasor solver are derived and discussed. Also, a method for coupling phasor RCF networks to time …

    south-carolina Repository record for Resistive Companion Dynamic Phasor Networks and Phasor to Time Domain Network Coupling (opens in a new tab)

  2. Theory of phasor-field imaging

    Phasor-field (P-field) imaging is a promising recent solution to the task of non-line-of-sight (NLoS) imaging, colloquially referred to as "seeing around corners". It consists of treating the oscillating envelope of amplitude-modulated, spatially-incoherent light as if it were itself an optical …

    mit Repository record for Theory of phasor-field imaging (opens in a new tab)

  3. PHASOR MEASUREMENT UNIT DATA VISUALIZATION

    The Phasor Measurement Units commonly referred to as PMUs is a tool for collecting fine-grained measurements in power systems ranging from phase angles, current flows and voltage levels. The valuable insight derived from analyzing such extensive amounts of data plays an important role in …

    csusb Repository record for PHASOR MEASUREMENT UNIT DATA VISUALIZATION (opens in a new tab)

  4. Accurate frequency estimation with phasor angles

    … order least error square approximation on the phasor angles of the input waveform. Then, a resampling based on the rough frequency estimation is carried out, followed by another second order least error square approximation to obtain the final results. The results of simulations using this …

    vt Repository record for Accurate frequency estimation with phasor angles (opens in a new tab)

  5. Advanced System Monitoring with Phasor Measurements

    Phasor Measurement Units (PMUs) are widely acknowledged as one of the most promising developments in the field of real-time monitoring of power systems. By aligning the time stamps of voltage and current phasor measurements that are consistent with Coordinated Universal Time (UTC), a coherent …

    vt Repository record for Advanced System Monitoring with Phasor Measurements (opens in a new tab)

  6. Applying spectral phasor analysis to DNA environments

    … and dynamics. The technique spectral phasor analysis is capable of characterising spectral shift associated with environmental changes throughout a live cell. Spectral phasor analysis can unmix fluorescent molecules without prior knowledge of their contribution to the spectra and …

    uws Repository record for Applying spectral phasor analysis to DNA environments (opens in a new tab)

  7. Phasor Measurement based Out-Of-Step Detection

    This thesis deals with Out-Of-Step conditions in a network, how to detect the events and how to make improvements on the protection devices that are being used today. Power systems and stability analysis are studied in general and Out-Of-Step conditions are reviewed in detail. Experiments with a …

    chalmers Repository record for Phasor Measurement based Out-Of-Step Detection (opens in a new tab)

  8. Evaluation and Standardizing of Phasor Data Concentrators

    … synchronized measurement device has arrived. The Phasor Measurement Units (PMU) is not only GPS time synchronized, but it also takes measurements as voltage and current phasors. PMUs are becoming an integral part in many power system applications from load flow analysis and state estimation to …

    vt Repository record for Evaluation and Standardizing of Phasor Data Concentrators (opens in a new tab)

  9. Phasor Domain Modeling of Type-III Wind Turbines

    … focuses on developing an accurate steady-state phasor model for Doubly Fed Induction Generator (DFIG)-based wind turbines (Type-III WTs). Unlike the classical synchronous or asynchronous generators, Type-III WTs are electronically coupled to the power grid. The steady-state and dynamic responses …

    usf Repository record for Phasor Domain Modeling of Type-III Wind Turbines (opens in a new tab)

  10. Power System State Estimation Using Phasor Measurement Units

    … other is a single load increment. In addition, phasor measurement unit (PMU) measurements are applied in state estimation to verify if they could solve the divergence problem and improve state estimation accuracy. The dissertation investigates the impacts of variations of line power flow …

    uky-thes Repository record for Power System State Estimation Using Phasor Measurement Units (opens in a new tab)

  11. DATA POISONING ATTACKS ON PHASOR MEASUREMENT UNIT DATA

    Phasor Measurement Units (PMUs) have been widely used in several regions to improve bulk power system situational awareness. PMUs provide utilities with enhanced monitoring and control capabilities and are regarded as one of the future's most important measuring devices for power systems. …

    csusb Repository record for DATA POISONING ATTACKS ON PHASOR MEASUREMENT UNIT DATA (opens in a new tab)

  12. Spectral phasor analysis of live cell lipid microenvironments

    … observation of which has been limited. Spectral Phasor Analysis detects small shifts in exogenous and endogenous fluorophore emissions caused by domain change with high spatial resolution, without requiring reference spectra. This project was designed to ascertain the suitability of Spectral …

    uws Repository record for Spectral phasor analysis of live cell lipid microenvironments (opens in a new tab)

  13. Spectral phasor analysis of live bacteria in biofilms

    … occur due to microenvironment changes. Spectral Phasor analysis enables the detection of these spectral shifts and their mapping within an image thereby providing an insight into cellular microenvironments. This thesis reports the application of Spectral Phasor in order to develop methodology …

    uws Repository record for Spectral phasor analysis of live bacteria in biofilms (opens in a new tab)

  14. Development of a Low-cost Phasor Measurement Unit

    … systems such as SCADA are being replaced by the Phasor Measurements Units due to their superior capabilities such as real-time and synchronize measurements. PMUs have many applications from gird protection to grid control, the down side however is that commercial PMUs have a high price tag …

    ttu Repository record for Development of a Low-cost Phasor Measurement Unit (opens in a new tab)

  15. Extracting Value from Time-synchronous Phasor Measurement Data

    … analyze ultra-high-resolution time-synchronous phasor measurements, also known as synchrophasors, thereby providing a comprehensive view of the entire power grid. Synchrophasors offer a multitude of benefits making them an indispensable tool for power systems. This dissertation focuses on …

    utk-theses Repository record for Extracting Value from Time-synchronous Phasor Measurement Data (opens in a new tab)

  16. Generalized dynamic phasor-based simulation for power systems

    … system simulation technique based on dynamic phasors and conventional power system simulation methods. The method developed in this work converts time-domain circuits to equivalent dynamic phasor representations. These dynamic phasor equivalents are then simulated using nodal analysis and …

    manitoba Repository record for Generalized dynamic phasor-based simulation for power systems (opens in a new tab)

  17. Three-Phase Linear State Estimation with Phasor Measurements

    Given the ability of the Phasor Measurement Unit (PMU) to directly measure the system state and the increasing implementation of PMUs across the electric power industry, a natural expansion of state estimation techniques would be one that employed the exclusive use of PMU data. Dominion Virginia …

    vt Repository record for Three-Phase Linear State Estimation with Phasor Measurements (opens in a new tab)

  18. Optimal Substation Coverage for Phasor Measurement Unit Installations

    … thus indirectly minimizing the synchrophasor deployment costs. Also presented is a brief history of the PMU and its applications along with the conventional Optimal PMU placement problem and the scope for expanding this work.

    vt Repository record for Optimal Substation Coverage for Phasor Measurement Unit Installations (opens in a new tab)

  19. Adaptive out-of-step relaying with phasor measurement

    … through the one year field test. Synchronized phasor measurements were used for the first time for relaying application, proving their ability to detect and analyze system disturbances through the measurement of angle differences between any two points in a system. It is shown that for a system …

    vt Repository record for Adaptive out-of-step relaying with phasor measurement (opens in a new tab)

  20. Spoofing GPS receiver clock offset of phasor measurement units

    … of a spoofing attack on the GPS receiver of a phasor measurement unit (PMU). We formulate the attack as an optimization problem where the objective is to maximize the difference between the time offset of the PMU's receiver clock before and after the attack. Since the PMU uses this clock offset …

    uiuc Repository record for Spoofing GPS receiver clock offset of phasor measurement units (opens in a new tab)

Page 1 of 35