Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Phasor Analysis"”.

  1. Visualizing Ischemic Skin Flap Necrosis Through Phasor Analysis of Autofluorescence Lifetime Images

    … objective of this study was to assess whether phasor FLIM could be used to evaluate skin flap status and treatment efficacy in ex vivo skin sections. Phasor maps revealed differences in growth factor treatment and region, but changes in skin flap autofluorescence at 755nm excitation and 460nm …

    arkansas Repository record for Visualizing Ischemic Skin Flap Necrosis Through Phasor Analysis of Autofluorescence Lifetime Images (opens in a new tab)

  2. Investigation of Manufacturing Tolerances on Cogging Torque and Torque Ripple in Permanent Magnet Synchronous Machines

    … in permanent magnet (PM) synchronous machines by phasor analysis, Taguchi method, and finite element method (FEM). The investigated manufacturing tolerances include PM tolerances, rotor eccentricities, tooth bulges, and additional air gaps for single-type tolerances, and interaction effects of PM …

    whiterose Download PDF for Investigation of Manufacturing Tolerances on Cogging Torque and Torque Ripple in Permanent Magnet Synchronous Machines (opens in a new tab)

  3. Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems

    … Traditional frequency-domain approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically …

    calpoly Repository record for Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems (opens in a new tab)

  4. WIDE OPERATING RANGE RESONANT CONVERTERS

    … rectifier transistors of the ICN converter. A phasor analysis of the ICN converter is performed to enable easier visualization of the operation of the ICN converter. Through this analysis, the soft-switching regions and minimum current operating point of the ICN converter are derived. Finally, …

    cornell Repository record for WIDE OPERATING RANGE RESONANT CONVERTERS (opens in a new tab)

  5. TIME-DOMAIN VOLTAGE STABILITY ASSESSMENT AND WIDE-AREA CONTROL

    … Steady-state approaches for voltage stability analysis use linearized equations based on power frequency phasor analysis using the Jacobian matrix of the power system. Using these conventional methods, nonlinearities and resultant harmonics are not addressed, nor are frequency-dependencies or …

    mtu Repository record for TIME-DOMAIN VOLTAGE STABILITY ASSESSMENT AND WIDE-AREA CONTROL (opens in a new tab)

  6. Tunable difference equations for the time-domain simulation of power system operating states

    … to traditional techniques such as the well-known phasor analysis and Newton-Raphson iterations. Additionally, the techniques developed do not use complex numbers, resulting in a faster matrix factorization for linear systems, or a smaller Jacobian matrix for non-linear systems. The main advantage …

    ubc Repository record for Tunable difference equations for the time-domain simulation of power system operating states (opens in a new tab) Download PDF for Tunable difference equations for the time-domain simulation of power system operating states (opens in a new tab)

  7. Raman probes for intracellular sensing

    … The sensor, in combination with spectral phasor analysis (SPA), was then used to assess the viability of healthy and UV-irradiated cells within the same field of view. Intracellular redox states have been quantified using fluorescent methods and surface enhanced Raman spectroscopy (SERS) …

    strathclyde Repository record for Raman probes for intracellular sensing (opens in a new tab)

  8. High-performance resonant converters for battery chargers : efficiency and dynamics improvement

    … based on Extended Describing Functions (EDF) and phasor analysis, which successfully predicts the system frequency response across low- to high-frequency regions, enabling high-bandwidth designs. As the proposed noise-tolerant SR methods improve the efficiency performance, the enhanced …

    ubc Repository record for High-performance resonant converters for battery chargers : efficiency and dynamics improvement (opens in a new tab) Download PDF for High-performance resonant converters for battery chargers : efficiency and dynamics improvement (opens in a new tab)

  9. ADVANCEMENTS IN TIME-DOMAIN MODELING OF POWER SYSTEM DISTURBANCES

    … the leakage inductances using Finite Element Analysis. Various challenges were addressed, and advances were made in the modeling and implementation in the EMTP time-domain environment. Further, with the help of developed techniques, winding fault characterization was made and simplification to …

    mtu Repository record for ADVANCEMENTS IN TIME-DOMAIN MODELING OF POWER SYSTEM DISTURBANCES (opens in a new tab)

  10. Computational Tools for Quantitative Autofluorescence Imaging

    … in static three-dimensional imaging, enabling analysis of mitochondrial motility and spatial distribution throughout the cell in high-resolution images for three different cell types: breast cancer MDA-MB-231 cells, epithelial MCF10A cells, and primary glial cells. Next, mitochondrial …

    tamu Repository record for Computational Tools for Quantitative Autofluorescence Imaging (opens in a new tab) Embargoed until 2028-05-01

  11. Computational Tools for Quantitative Autofluorescence Imaging

    … in static three-dimensional imaging, enabling analysis of mitochondrial motility and spatial distribution throughout the cell in high-resolution images for three different cell types: breast cancer MDA-MB-231 cells, epithelial MCF10A cells, and primary glial cells. Next, mitochondrial …

    tamu Repository record for Computational Tools for Quantitative Autofluorescence Imaging (opens in a new tab) Embargoed until 2028-05-01

  12. Multivariate Optical Imaging of the Oxygen-Metabolism Axis

    … both because of instrumentation limitations and analysis tools. This work aims to define a blueprint for high dimensional study of the oxygen metabolism axis to enable more sensitive study metabolic reprogramming. We hypothesized (1) multivariate imaging of metabolic and oxygenation metrics in ex …

    arkansas Repository record for Multivariate Optical Imaging of the Oxygen-Metabolism Axis (opens in a new tab)

  13. Towards Three-Phase Dynamic Analysis of Large Electric Power Systems

    … set of differential equations, making such an analysis extremely time consuming. For the purpose of electromechanical transient analysis, TPDA exploits the difference in the order of time constants and adopts phasor analysis of the electric network, solving differential equations only for the …

    vt Repository record for Towards Three-Phase Dynamic Analysis of Large Electric Power Systems (opens in a new tab)

  14. Vector-analyzed fluorescence lifetime microscopy approach: new insights into cell metabolism and calcium signaling, in vitro and in vivo

    … are challenging. Here, the method of phasor analysis has been adopted and applied to stimulated/non-stimulated ROS-producing lymphocytes. This way it was possible to directly image the temporal dynamics of NADPH oxidase activation and its requirement for triggering NETosis in …

    fu-berlin Repository record for Vector-analyzed fluorescence lifetime microscopy approach: new insights into cell metabolism and calcium signaling, in vitro and in vivo (opens in a new tab)

  15. Optical Biopsy Instrument Design and Parameter Extraction from Hyperspectral Time-Resolved Fluorescence Data

    Complete resection is correlated to better patient outcome in aggressive cancers such as glioblastoma. Optical biopsy refers to a family of techniques utilizing optical properties of living targets to make diagnoses where a biopsy would conventionally be used. Such a technology can potentially …

    mcmaster Repository record for Optical Biopsy Instrument Design and Parameter Extraction from Hyperspectral Time-Resolved Fluorescence Data (opens in a new tab)

  16. Development of the multi-scale dynamic modeling techniques for multi-modal brain recordings

    … dynamics is mainly limited by the single-scale analysis. My goal is to develop a multi-scale dynamical model for the collective activity of neuronal populations. First, I introduced a bio-inspired deep learning approach, termed NeuroBondGraph Network (NBGNet), to capture cross-scale dynamics …

    texas Repository record for Development of the multi-scale dynamic modeling techniques for multi-modal brain recordings (opens in a new tab)

  17. Identification, distribution and intracellular melanin profiling of melanocytes and melanocytic lesions in the human choroid

    … spectral and lifetime acquisition and phasor plot segmentation. This approach successfully and consistently confirmed intracellular melanins as endogenous fluorophores, and as quantifiable and reliable biomarkers for variably pigmented HCMs. As a proof-of-concept, the 2PM FLIM …

    unsw Repository record for Identification, distribution and intracellular melanin profiling of melanocytes and melanocytic lesions in the human choroid (opens in a new tab)

  18. Resistive Companion Dynamic Phasor Networks and Phasor to Time Domain Network Coupling

    The resistive companion form (RCF) is extended to phasor and dynamic phasor models. A phasor solver is implemented in the Virtual Test Bed (VTB) simulation environment. Several models targeting the VTB phasor solver are derived and discussed. Also, a method for coupling phasor RCF networks to time …

    south-carolina Repository record for Resistive Companion Dynamic Phasor Networks and Phasor to Time Domain Network Coupling (opens in a new tab)