Results 1 to 6 of 6 for “"Phosphorescent tracer"”
-
A Novel Approach To Residence Time Distribution
… the activation, injection, and measurement of phosphorescent tracer particles in a fluidized bed riser to determine the Residence Time Distribution (RTD) of solids flow within a fluidized bed riser. The instrument was implemented in a dual-stage transparent scale model fluidized bed riser. …
-
Development of radial velocity measurements for high pressure fuel injection
… Here, dodecane is doped with a long-lived phosphorescent tracer, consisting of Eu-TTA-TOPO. A thin laser-light sheet excites the centerline of the quasi-steady spray, leaving a distinct mark on it. A high-speed CCD camera coupled with an intensifier is used to capture a pair of images …
-
Development of radial velocity measurements for high pressure fuel injection- An introduction to a novel experimental approach
… Here, dodecane is doped with a long-lived phosphorescent tracer, consisting of Eu-TTA-TOPO. A thin laser-light sheet excites the centerline of the quasi-steady spray, leaving a distinct mark on it. A high-speed CCD camera coupled with an intensifier is used to capture a pair of images …
-
Hydrodynamics and solids mixing behaviour of fluidized beds with inclined-hole distributor
… time distribution studies were conducted using phosphorescent tracer particles belonging to Group A, activated by ultraviolet light. The turnover time was estimated using the bubbling bed model and found to match the experimental results well. It was found that the probes installed at the walls …
-
Residence Time Distribution Measurements in a Downer Reactor & Gas-Solids Separator
… methods, including solids RTD measurement using phosphorescent tracer and stripping efficiency measurement using CO2 tracer, were used to further assess the separator performance. The separator performance was found to be strongly dependent on the separator cone diameter. A novel, objective …
-
Development of a new technique for determining the RTD of a dispersed solid phase and its application in a deep fluidized bed
… avec le carbure de silicium (SiC) et le pigment phosphorescent (Lumilux® Green SN-F50 WS) a été utilisé en tant que traceur. Une étude expérimentale préliminaire a été réalisée dans un lit fluidisé bouillonnant simple afin de valider la méthodologie proposée de mesure de la DTS. Dans un deuxième …