Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 45 for “"Photoacoustic microscopy"”.
-
Functional photoacoustic microscopy
… dissertation focuses on laser-based noninvasive photoacoustic microscopy of subsurface structures in vivo. Photoacoustic microscopy is a hybrid imaging modality that combines the high-resolution advantage of ultrasonic imaging in deep tissue with the high-contrast advantage of optical imaging. It …
-
Optical-Resolution Photoacoustic Microscopy
Optical microscopy, providing valuable biomedical insights at the cellular and organelle levels, has been widely recognized as an enabling technology. Mainstream optical microscopy technologies, including single-/multi-photon fluorescence microscopy and OCT, have demonstrated extraordinary …
-
Multi-contrast Photoacoustic Microscopy
Photoacoustic microscopy is a hybrid imaging modality with high spatial resolution, moderate imaging depth, excellent imaging contrast and functional imaging capability. Taking full advantage of this powerful weapon, we have investigated different anatomical, functional, flow dynamic and metabolic …
-
High-Speed Photoacoustic Microscopy In Vivo
… goal of this research is to develop a novel photoacoustic microscopy: PAM) technology capable of high-speed, high-resolution 3D imaging in vivo. PAM combines the advantages of optical absorption contrast and ultrasonic resolution for deep imaging beyond the quasi-ballistic regime. Its high …
-
In Vivo Vascular Imaging with Photoacoustic Microscopy
Photoacoustic (PA) tomography (PAT) has received extensive attention in the last decade for its capability to provide label-free structural and functional imaging in biological tissue with highly scalable spatial resolution and penetration depth. Compared to modern optical modalities, PAT offers …
-
Developing the next-generation photoacoustic microscopy systems
Photoacoustic imaging (PAI) is a biomedical technique 100% sensitive to optical absorption produced by either absorbing sources such as tissue or contrast agents upon laser illumination. In the past decade, photoacoustic microscopy (PAM) has advanced as a PAI technique able to image high-resolution …
-
Photoacoustic microscopy of nanoparticles in cells and tissues
Molecular photoacoustic imaging is an exciting new field that promises to visualize molecular indicators of disease. The objective of this dissertation is to progress molecular imaging by providing a photoacoustic microscopy platform to better validate in vivo molecular photoacoustic imaging, …
-
Submicron-resolution Photoacoustic Microscopy of Endogenous Light-absorbing Biomolecules
Photoacoustic imaging in biomedicine has the unique advantage of probing endogenous light absorbers at various length scales with a 100% relative sensitivity. Among the several modalities of photoacoustic imaging, optical-resolution photoacoustic microscopy (OR-PAM) can achieve high spatial …
-
In vivo blood oxygenation level measurements using photoacoustic microscopy
… blood oxygenation level using multi-wavelength photoacoustic measurements. Photoacoustic microscope is utilized to acquire images of microvasculature in smallanimal skin. Owing to endogenous optical contrast, optical spectral information obtained from spectral photoacoustic measurements are …
-
Inverse opal scaffolds and photoacoustic microscopy for regenerative medicine
… of this work deals with the novel application of photoacoustic microscopy (PAM), a volumetric imaging modality recently developed, to tissue engineering and regenerative medicine, in the context of non-invasive imaging and quantification of cells and tissues grown in PLGA inverse opal scaffolds, …
-
Optically-Transparent Focused Transducers on Polymer Substrates for Photoacoustic Microscopy
Photoacoustic microscopy (PAM) is a hybrid modal imaging technique with the integration of focused optical and acoustical beams. However, conventional ultrasound transducers for photoacoustic (PA) signal detection are not optically transparent, which could block the passage of the laser beam for …
-
PHOTOACOUSTIC MICROSCOPY OF MALIGNANT MELANOMA IN THE IN VIVO MOUSE MODEL
… of penetration depth and sufficient contrast. Photoacoustic microscopy improves on these techniques by utilizing optical absorption of biological components and acquiring acoustic waves from optical stimulation, yielding high contrast, while retaining high resolution and sufficient depth …
-
Photoacoustic Microscopy and Photoacoustic Computed Tomography Using High-frequency Linear Array Ultrasonic Transducers
Photoacoustic tomography (PAT) is a highly promising imaging technology which forms images by detecting the induced pressure waves resulting from pulsed light absorption in biological tissues. Because the excitation source is light, PAT is a very safe, non-ionizing, and non-carcinogenic imaging …
-
High-Resolution Label Free Imaging of Endogenous Chromophore via Non-Linear Photoacoustic Microscopy
… contrast imaging, such as fluorescence confocal microscopy, require exogenous contrast agents to gain access to relevant biomolecules. All non-fluorescing biomolecules must therefore be tagged by a fluorescent marker to be visible in fluorescence confocal images. While these markers are …
-
Advancing the portability, field of view, and spatiotemporal resolution of multi-parametric photoacoustic microscopy
… imaging with high spatial resolution in vivo, photoacoustic microscopy (PAM) is an emerging tool in biomedical research. Further, recent advances in multi-parametric acquisition and analysis make PAM uniquely capable of simultaneously mapping the total concentration of hemoglobin (CHb), oxygen …
-
Instrumentation Of Fast Widefield Photoacoustic Microscopy System With High Fidelity Data Enhancement And Storage
Laser scanning photoacoustic microscopy (LS-PAM) is a simple instrumentation of photoacoustic microscopy (PAM) system. However, existing LS-PAM systems pose some limitations. First, they utilize inefficient laser scanning mechanism that limits their capability to image large areas at higher speeds. …
-
Deep Learning Applications in Light-based Ultrasound Imaging: Photoacoustic Microscopy, Photoacoustic Tomography, and Passive Cavitation Mapping
… in light-based ultrasound imaging, specifically photoacoustic microscopy (PAM), photoacoustic computed tomography (PACT), and passive cavitation mapping (PCM). In PAM, we investigate the limitation imposed by laser repetition rates and the resulting tradeoff between spatial sampling density and …
-
Study of Various Detection Mechanisms for Photoacoustic Imaging
Photoacoustic imaging (PAI) is a developing imaging technique that has been researched for several clinical applications including oncology, neurology, dermatology and ophthalmology. PAI combines the benefits of pure optical and acoustic imaging to attain optical absorption contrast images. There …
-
Translational Ultrasound-Photoacoustic Imaging for Quantitative and Functional Cancer Diagnosis
… and functional insights into cancer biology. Photoacoustic imaging (PAI), which detects ultrasonic signals generated by optical absorption, combines the strengths of both modalities, achieving optical contrast with ultrasonic resolution and depth. When co-registered with ultrasound (US), the …
-
A Low-cost Microvascular Phantom for Photoacoustic Imaging Using Loofah
Existing photoacoustic phantoms are inadequate for mimicking the complex microvascular structures found in human tissue due to their inability to replicate varying sizes and distri- butions of vasculature. This limitation underscores the need for a new material capable of replicating intricate …
Page 1 of 3