Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 148 for “"Photon beams."”

  1. Study of wedged asymmetric photon beams

    … monitor units (MUs) in wedged asymmetric photon beams as implemented in treatment planning systems have their limitations. In this work, the dose calculations for rectangular wedged asymmetric fields by the Eclipse treatment planning system were tested by direct comparison to ion chamber …

    ubc Repository record for Study of wedged asymmetric photon beams (opens in a new tab)

  2. Physical parameters of narrow photon beams in radiosurgery

    … of radiosurgery are narrow circular radiation beams, stringent requirements on the numerical ($ pm$2%) and spatial ($ pm$1 mm) accuracy of dose delivery to the target and the need for sharp dose fall-offs outside the target volume. Physical aspects of radiosurgery based on isocentric linear …

    mcgill Repository record for Physical parameters of narrow photon beams in radiosurgery (opens in a new tab)

  3. In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams

    … (n-type and p-type) under different radiation beams.In the temperature dependence study, the systematic study on the dose rate dependence of svwt (sensitivity variation with temperature) was performed. It was concluded that sufficient preirradiation can eliminate dose rate dependence of svwt. …

    usf Repository record for In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams (opens in a new tab)

  4. Density compensated small-field dosimeters : evaluation in photon beams

    Nowadays small photon fields are widely used in the delivery of advanced radiotherapy techniques to cancer patients. Accurate calculation of the radiation dose received by patients is critical to ensure effective radiotherapy treatments, while limiting as much as possible undesired complications …

    liverpool Repository record for Density compensated small-field dosimeters : evaluation in photon beams (opens in a new tab)

  5. Intensity modulation of therapeutic photon beams using a rotating multileaf collimator

    This thesis describes the development and implementation of a novel method of delivering intensity modulated radiation therapy (IMRT) that provides greater accuracy and spatial resolution than currently available methods. Through improvements in multileaf collimator (MLC) based fluence generation, …

    ubc Repository record for Intensity modulation of therapeutic photon beams using a rotating multileaf collimator (opens in a new tab)

  6. IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams

    … a uniform energy fluence distribution of the photon beam and make it suitable for clinical use. Recently, linacs without flattening fifilter (Flattening FilterFree - FFF) are increasingly used in radiotherapy because of its benefifits, e.g. high dose rate (2000 MU/min), reduced scattered and …

    qucosa-diss Repository record for IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams (opens in a new tab)

  7. Monte Carlo study of ion chamber response in low energy photon beams

    … treatments. However, 192Ir emits a wide photon spectrum (10 keV to 900 keV) which impedes the creation of an 192Ir primary standard. The 192Ir air kerma calibration factor is derived by interpolating between 60Co, 137Cs and hard orthovoltage air kerma calibration factors obtained from a …

    mcgill Repository record for Monte Carlo study of ion chamber response in low energy photon beams (opens in a new tab)

  8. Penumbral Distributions For High-energy Radiotherapy Photon Beams: Experimental And Theoretical Determinations

    … of high-energy radiotherapy units namely, the photon-fluence and the dose distributions. The difference between these two distributions is associated with the lateral spread of the second electrons and is strongly dependent on the beam energy and electron density of the medium of …

    uwo Repository record for Penumbral Distributions For High-energy Radiotherapy Photon Beams: Experimental And Theoretical Determinations (opens in a new tab)

  9. Dose distributions in the buildup region of megavoltage linear accelerator photon beams

    … in the buildup region of megavoltage photon beams from linear accelerators. Most of the work was carried out using Monte Carlo calculation techniques. These techniques were used to calculate bremsstrahlung photon spectra, electron contamination in the photon beams, depth-dependent mass …

    ucl Repository record for Dose distributions in the buildup region of megavoltage linear accelerator photon beams (opens in a new tab)

  10. A SYSTEM POR THE CALCULATION OP DOSE PRODUCED BY EXTERNAL PHOTON BEAMS

    External photon beam therapy is a well established technique in the treatment of cancer. For the safe and effective use of this technique it is essential that the distribution of dose which would be produced by a given photon beam, or combination of photon beams, be known prior to irradiation. This …

    sask Repository record for A SYSTEM POR THE CALCULATION OP DOSE PRODUCED BY EXTERNAL PHOTON BEAMS (opens in a new tab)

  11. Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy

    Buildup dose of Mega Voltage (MV) photon beams can be a limiting factor in intensitymodulated radiation therapy (IMRT) treatments. Excessive doses can cause patient discomfort and treatment interruptions, while underdosing may lead to local failure. Many factors which contribute to buildup dose, …

    usf Repository record for Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy (opens in a new tab)

  12. Evaluation of the PEREGRINE Monte Carlo dose calculation code for 6 MV photon beams

    … dose calculation algorithms employed in external photonbeam treatment planning is limited by their inability to fully model the radiation source andaccount for the electron fluence perturbations which occur in regions of non-uniform density.In this work, we evaluated the dosimetric accuracy of the …

    mcgill Repository record for Evaluation of the PEREGRINE Monte Carlo dose calculation code for 6 MV photon beams (opens in a new tab)

  13. A Dosimetric Comparison of VMAT Prostate Plans Designed with 10MV vs 18MV Photon Beams

    Despite potential benefits of using 18MV photon beam for treatment of deep-seated tumors with highly conformal radiation treatment approaches, such as intensity modulated radiation therapy (IMRT) and volumetrically modulated arc therapy (VMAT), this energy choice remains a taboo. The main reason is …

    ohiolink Repository record for A Dosimetric Comparison of VMAT Prostate Plans Designed with 10MV vs 18MV Photon Beams (opens in a new tab)

  14. Monte Carlo Study of the Dosimetry of Small-Photon Beams Using CMOS Active Pixel Sensors

    … common treatment modality that uses very small photon fields. This technique imposes high dosimetric standards and complexities that remain unsolved. In this work the dosimetric performance of CMOS active pixel sensors is presented for the measurement of small-photons beams. A novel CMOS active …

    ucl Repository record for Monte Carlo Study of the Dosimetry of Small-Photon Beams Using CMOS Active Pixel Sensors (opens in a new tab)

  15. Scatter factors and peak scatter factors for cobalt-60, 6 MV, 10, and 18 MV photon beams

    … method for measuring the PSF for megavoltage photon beams is developed. The method is applied to Co-60, 6 MV, 10 MV, and 18 MV photon beams using water, polytyrene, and solid water phantoms. The measured PSFs are compared to tabulated PSF and Normalized Peak Scatter Factors (NPSF) published in …

    mcgill Repository record for Scatter factors and peak scatter factors for cobalt-60, 6 MV, 10, and 18 MV photon beams (opens in a new tab)

  16. Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose

    … lung SABR treatments for 10X, 6X, and 10X-FFF beams. Flattening Filter Free (FFF) radiotherapy photon beams exhibit high dose rates as compared to standard flattened photon beams. The high dose rates available with FFF beams make them ideal for high dose treatments, such as Volumetric Modulated …

    uvic Repository record for Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose (opens in a new tab)

  17. Monte Carlo conversion for the Australian primary standard of absorbed dose to water in high energy photon beams

    … the calibration of linear accelerator (linac) beams and many treatment planning systems. The work in this thesis is devoted to the establishment of the Australian primary standard of absorbed dose with clinically used high energy photon beams, and in particular to the Monte Carlo methods …

    adelaide Repository record for Monte Carlo conversion for the Australian primary standard of absorbed dose to water in high energy photon beams (opens in a new tab)

Page 1 of 8