Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 43 for “"Photon-Counting detector"”

  1. Characterization of the MIC photon counting detector

    A new photon counting detector, MIC, has been developed at UCL and is an enhanced performance version of the highly successful IPCS in use at a number of large ground based optical telescopes throughout the world. This detector is light weight, compact and has a low power consumption making it …

    ucl Repository record for Characterization of the MIC photon counting detector (opens in a new tab)

  2. Development of the BigMIC image photon counting detector

    BigMIC is a large area image photon counting system that has been designed for applications in astronomy requiring the highest sensitivity and resolution such as echelle spectroscopy with very large telescopes. It consists of a 75 mm diameter image intensifier fibre-optically coupled to a fast …

    ucl Repository record for Development of the BigMIC image photon counting detector (opens in a new tab)

  3. A high performance, microchannel plate based, photon counting detector for space use

    … development of a microchannel plate (MCP) based photon counting detector using the Spiral Anode (SPAN) as a readout. This detector was one of two being evaluated for use in the Optical Monitor for ESA's X-ray Multi Mirror satellite. Throughout this thesis, where possible, the underlying physical …

    ucl Repository record for A high performance, microchannel plate based, photon counting detector for space use (opens in a new tab)

  4. In-silico Modeling, Optimization, and Harmonization of Photon-Counting Detector Computed Tomography

    … validate, and demonstrate a customizable photon-counting detector computed tomography (PCD-CT) model for optimizing energy settings and generating harmonized virtual monoenergetic images to enhance spectral separation, inter- and intra-scanner consistency, and material imaging accuracy. …

    duke Repository record for In-silico Modeling, Optimization, and Harmonization of Photon-Counting Detector Computed Tomography (opens in a new tab)

  5. Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system

    … therapy planning. Recent advancements in photon-counting detector (PCD) technology have led to the development of photon-counting detector CT (PCD-CT), a promising innovation offering high spatial resolution and superior contrast-to-noise ratios compared to traditional CT. PCD-CT excels in …

    uvic Repository record for Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system (opens in a new tab)

  6. GPU-ENABLED MONTE CARLO SIMULATION AND QUANTITATIVE ACTIVITY RECONSTRUCTION FOR LIMITED-ANGLE LU-177 IMAGING WITH A PHOTON-COUNTING DETECTOR

    … limited-angle quantitative Lu-177 imaging using photon-counting detectors through a patient-based Monte Carlo and system-matrix reconstruction framework. A GPU-enabled Monte Carlo framework was used to model photon emission, transport, collimation, and photon-counting detection. The simulation …

    jhu Repository record for GPU-ENABLED MONTE CARLO SIMULATION AND QUANTITATIVE ACTIVITY RECONSTRUCTION FOR LIMITED-ANGLE LU-177 IMAGING WITH A PHOTON-COUNTING DETECTOR (opens in a new tab)

  7. Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging

    … CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). Materials and methods: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were …

    zurich Repository record for Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging (opens in a new tab) Restricted access

  8. X-ray phase contrast imaging: Application of Bragg demagnifier optics for imaging of cm-scale objects with km propagation distance within a meter

    … When combined with a Bragg magnifier and single photon-counting detector, the system enables imaging at moderate resolution with reduced radiation dose. This approach has potential applications in biological imaging and medical diagnostics.

    freiburg-diss Repository record for X-ray phase contrast imaging: Application of Bragg demagnifier optics for imaging of cm-scale objects with km propagation distance within a meter (opens in a new tab)

  9. Machine Learning Methods of Material Decomposition in Special Computed Tomography Using Photon Counting Detectors

    Energy-resolved photon counting detectors have potential improvements over conventional scintillating x-ray detectors and can be used for spectral computed tomography (CT) applications such as material decomposition. However, photon counting detector are difficult to model because they have many …

    marquette Repository record for Machine Learning Methods of Material Decomposition in Special Computed Tomography Using Photon Counting Detectors (opens in a new tab)

  10. The Radiative Lifetime Measurement of the 6sSg(40, 23) Rovibrational Excited State of Sodium Molecules Using Time Correlated Single Photon Counting Technique

    … was measured using a time-correlated single photon counting technique. In the experiment, the ground XsSg(7, 23) state was thermally populated and the molecules were excited to the 6sSg(40, 23) state using two pulseddye lasers via the intermediate AsSu(37, 24) state. The fluorescence spectrum …

    ohiolink Repository record for The Radiative Lifetime Measurement of the 6sSg(40, 23) Rovibrational Excited State of Sodium Molecules Using Time Correlated Single Photon Counting Technique (opens in a new tab)

  11. Image analysis and radiation standardization for novel breast CT in clinical applications

    … 8 1.3.4 Spiral breast CT equipped with photon-counting detector technology 9 1.4 Imaging Radiation Dose and Secondary Cancer Risk 10 1.4.1 Effect of ionizing radiation 10 1.4.2 Radiation dose assessment 11 1.4.3 Mean glandular dose 12 1.5 Aim and Outline of the Thesis 12 1.5.1 …

    zurich Repository record for Image analysis and radiation standardization for novel breast CT in clinical applications (opens in a new tab) Restricted access

  12. Multivariate Statistical Methods that Enable Fast Raman Spectroscopy

    … optical filters to efficiently capture Raman photons and multiplex them onto either one or two photon counting detector(s). This method, referred to as optimal-binary compressive detection (OB-CD), allows for the collection of chemical information in 10’s of microseconds, rather than …

    purdue-thes Repository record for Multivariate Statistical Methods that Enable Fast Raman Spectroscopy (opens in a new tab)

  13. Singlet oxygen luminescence detection

    The detection of a single photon at 1270 nm wavelength allows the direct monitoring of Singlet Oxygen (1O2), making Singlet Oxygen Luminescence Detection (SOLD) a powerful dosimetry technique for photodynamic therapy in the treatment of cancer. However, the direct detection of 1O2 emission at 1270 …

    glasgow Repository record for Singlet oxygen luminescence detection (opens in a new tab)

  14. Dual Energy Contrast Enhanced Mammography Using a Photon Counting Spectral Detector

    … security, and geoscience. Recent advancements in detector fabrication and technology have enabled creation of X-ray photon counting detectors with energy-resolving capabilities. The additional spectral information captured by these detectors has spurred development of more advanced material …

    houston Repository record for Dual Energy Contrast Enhanced Mammography Using a Photon Counting Spectral Detector (opens in a new tab) Embargoed until 2026-12-01

  15. Development of microchannel plate detectors for spatially linear high resolution imaging with the Vernier anode

    … of events detected in a microchannel plate (MCP) detector. Although offering many advantages such as electronic simplicity and ease of manufacture, they can exhibit certain image stability and linearity problems largely associated with charge collection by the anode. Described here are experiments …

    ucl Repository record for Development of microchannel plate detectors for spatially linear high resolution imaging with the Vernier anode (opens in a new tab)

  16. Spectral X-ray imaging using deep learning

    … linear attenuation coefficient, which depends on photon energy. Traditional X-ray sources used in CT systems are polyenergetic, generating photons across a spectrum of energies. However, conventional CT systems rely on energy-integrating detectors that cannot resolve individual photon energies, …

    soton Repository record for Spectral X-ray imaging using deep learning (opens in a new tab)

  17. Distributed X-ray Sources for X-ray Imaging and Small Animal FLASH Irradiator

    … was assembled and tested. With a multi-row CdTe photon-counting detector, forty-eight x-ray fan beams of MPTEX source were able to cover a 25-cm cross-sectional and 8-cm axial field of view. Tetrahedron-beam x-ray imaging techniques using MPTEX source were demonstrated.Ultra-high dose rate …

    wustl Repository record for Distributed X-ray Sources for X-ray Imaging and Small Animal FLASH Irradiator (opens in a new tab)

  18. MEASUREMENT AND CHARACTERIZATION OF DISTURBANCE WAVES IN PRESSURIZED TWO-PHASE FLOW WITH X-RAY DENSITOMETRY AND NOVEL PROCESSING METHODS

    … ultra-thin wall test section and a single-photon counting detector enabled high-resolution, non-intrusive measurements of flow structure. A novel image processing framework was introduced to correct for noise sources such as non-uniform illumination, frame instability, and count-rate …

    mcmaster Repository record for MEASUREMENT AND CHARACTERIZATION OF DISTURBANCE WAVES IN PRESSURIZED TWO-PHASE FLOW WITH X-RAY DENSITOMETRY AND NOVEL PROCESSING METHODS (opens in a new tab)

  19. Experimental entanglement distillation of continuous-variable optical states

    <p>Entangled photons are ideally suited to the transmission of photonic quantum information. Mitigating the effects of decoherence is fundamental to distributing photonic entanglement across large distances. One such proposal is entanglement distillation, in which operations on a large ensemble of …

    oxford Repository record for Experimental entanglement distillation of continuous-variable optical states (opens in a new tab)

Page 1 of 3