Showing 1 to 20 of 59 for “"Photoplethysmogram"”.

  1. Using the Photoplethysmogram Signal to Assess Cardiovascular Health

    The photoplethysmogram signal (PPG) is a routine, non-invasive and continuously recorded signal used both in and out of clinical settings currently for monitoring heart rate and blood oxygen saturation. These metrics are however barely scratching the surface of the PPG’s true clinical and …

    kings Repository record for Using the Photoplethysmogram Signal to Assess Cardiovascular Health (opens in a new tab) Download PDF for Using the Photoplethysmogram Signal to Assess Cardiovascular Health (opens in a new tab)

  2. Novel smartphone-based photoplethysmogram signal analysis for health monitoring applications

    According to the statement by the U.S. Food and Drug Administration (FDA), digital health technologies are improving the medical outcomes and efficiency of the medical and healthcare system [1]. Digital health is defined as categories such as “mobile health (mHealth), health information technology …

    ttu Repository record for Novel smartphone-based photoplethysmogram signal analysis for health monitoring applications (opens in a new tab)

  3. Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram

    … using the characterization of pulse oximetry photoplethysmogram (PPG). To evaluate the algorithms, we recorded the oxygen saturation (SpO₂) and PPG signals from 160 children using a phone-based oximeter consisting of a microcontroller-based pulse oximeter module interfacing a smartphone. This …

    ubc Repository record for Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram (opens in a new tab) Download PDF for Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram (opens in a new tab)

  4. Cuffless ambulatory blood pressure measurement using the photoplethysmogram and the electrocardiogram

    … commonly acquired by wearable sensors: the photoplethysmogram (PPG) and the electrocardiogram (ECG). Given the diverse mechanisms by which the autonomic nervous system regulates BP, I developed methodologies using data from multiple individuals with BP perturbed by various, diverse, …

    oxford Repository record for Cuffless ambulatory blood pressure measurement using the photoplethysmogram and the electrocardiogram (opens in a new tab)

  5. A Statistical Framework for Non-Contact Heart Rate Estimation via Photoplethysmogram Imaging

    Although medical progress and increased health awareness over the last 60 years have reduced death rates from cardiovascular disease by more than 75%, cardiovascular disease remains one of the leading causes of death, hospitalization, and cause of prescription drug use. Resting heart rate can act …

    waterloo Repository record for A Statistical Framework for Non-Contact Heart Rate Estimation via Photoplethysmogram Imaging (opens in a new tab)

  6. Machine learning techniques for the prediction of systolic and diastolic blood pressure utilising the photoplethysmogram

    … such as, the Electrocardiogram (ECG) and the Photoplethysmogram (PPG). In particular, indirect cuffless BP measurement techniques using pulse transit time and pulse arrival time have been extensively investigated over the last few decades. However, these techniques require two measurement …

    city-london Download PDF for Machine learning techniques for the prediction of systolic and diastolic blood pressure utilising the photoplethysmogram (opens in a new tab)

  7. Accessible audio-visual system for neonatal health monitoring

    … assessment. For video analysis, extraction of photoplethysmogram and heart rate were demonstrated in clinically obtained neonatal videos. This was achieved through the development of a state-of-the-art face detector, in combination with an adapted region of interest tracker. Skin regions were …

    ubc Repository record for Accessible audio-visual system for neonatal health monitoring (opens in a new tab) Download PDF for Accessible audio-visual system for neonatal health monitoring (opens in a new tab)

  8. A Wireless Wearable System for Closed-Loop Stress Detection and Mitigation

    … for continuous measurement of photoplethysmogram (PPG) and acceleration data, providing insights into stress levels of a user. The thesis documents the design process, decisions, and optimizations related to the device’s hardware, firmware, and supporting software, along with …

    gatech Repository record for A Wireless Wearable System for Closed-Loop Stress Detection and Mitigation (opens in a new tab)

  9. Comparative analysis of similarity measures for multidimensional streaming data /

    … detection via ECG (Electrocardiogram) using PPG (Photoplethysmogram) as an additional source of information via multidimensional streaming time series anomaly detection algorithms and deep learning algorithms. Some limitations have been made in order to make this framework applicable to modern …

    vilnius Repository record for Comparative analysis of similarity measures for multidimensional streaming data / (opens in a new tab)

  10. Continuous Cardiorespiratory Monitoring Using Ballistocardiography From Load Cells Embedded in a Hospital Bed

    … model, both using multi-channel BCG and the photoplethysmogram (PPG) signals to extract features. Overall, this work established methods to enable non-invasive and continuous monitoring of standard vital signs utilizing the sensors already embedded in commonly-deployed commercially available …

    gatech Repository record for Continuous Cardiorespiratory Monitoring Using Ballistocardiography From Load Cells Embedded in a Hospital Bed (opens in a new tab)

  11. BEst (Biomarker Estimation): Health Biomarker Estimation Non-invasively and Ubiquitously

    … the region of interest in a video and created photoplethysmogram signals. I created features from image histograms and PPG signals. I used the Partial Least Squares Regression and Support Vector Machine Regression tools to analyze input features and to build hemoglobin prediction models. Using …

    marquette Repository record for BEst (Biomarker Estimation): Health Biomarker Estimation Non-invasively and Ubiquitously (opens in a new tab)

  12. Human Activity Recognition: A Comparative Study to Assess the Contribution Level of Accelerometer and vital Signals

    … (3D-ACC), electrocardiogram (ECG), photoplethysmogram (PPG) signals acquired from 15 individuals while per- forming daily activities. We extracted hand-crafted time and frequency domain features, then we applied correlation-based feature selection approach to reduce feature-set …

    concordia Download PDF for Human Activity Recognition: A Comparative Study to Assess the Contribution Level of Accelerometer and vital Signals (opens in a new tab)

  13. Affective Computing Through Time-series Representation Learning

    … of wearable physiological time-series like Photoplethysmogram (PPG) lacks the detailed information provided by Electrocardiogram (ECG), limiting the predictive power in affective state detection. To overcome this, we present the Region Disentangled Diffusion Model (RDDM), a novel diffusion …

    queens Repository record for Affective Computing Through Time-series Representation Learning (opens in a new tab)

  14. Robust and Analytical Cardiovascular Sensing

    The photoplethysmogram (PPG) is a noninvasive cardiovascular signal related to the pulsatile volume of blood in tissue. The PPG is user-friendly and has the potential to be measured remotely in a contactless manner using a regular RGB camera. In this dissertation, we study the modeling and …

    maryland Repository record for Robust and Analytical Cardiovascular Sensing (opens in a new tab)

  15. Energy-efficient recurrent neural network hardware architecture for heart rate estimation based on photoplethysmography

    … heart rate estimation application from photoplethysmogram signals. This approach combines binarization and quantization techniques to reduce computation requirements, making the model more suitable for hardware implementation. A custom hardware architecture is proposed for this …

    brazil-ufrgs Repository record for Energy-efficient recurrent neural network hardware architecture for heart rate estimation based on photoplethysmography (opens in a new tab)

  16. Advanced Signal Processing Solutions for Brain-Computer Interfaces: From Theory to Practice

    … processes Electrocardiography (ECG) and Photoplethysmogram (PPG) signals via an adaptive Kalman filtering approach.

    concordia Download PDF for Advanced Signal Processing Solutions for Brain-Computer Interfaces: From Theory to Practice (opens in a new tab)

  17. AN INITIAL EVALUATION OF IBI VIZEDIT: AN RSHINY APPLICATION FOR OBTAINING ACCURATE ESTIMATES OF AUTONOMIC REGULATION OF CARDIAC ACTIVITY

    Photoplethysmogram (PPG) sensors are increasingly used to collect individual heart rate data during laboratory assessments and psychological experiments. PPG sensors are relatively cheap, easy to use, and non-invasive alternatives to the more common electrodes used to produce electrocardiogram …

    maryland Repository record for AN INITIAL EVALUATION OF IBI VIZEDIT: AN RSHINY APPLICATION FOR OBTAINING ACCURATE ESTIMATES OF AUTONOMIC REGULATION OF CARDIAC ACTIVITY (opens in a new tab)

  18. Noncontact Vital Signs Detection

    … measurement, non-contact sensors such as imaging photoplethysmogram (IPPG) and Doppler radar system have been proposed for cardiorespiratory rates detection by researchers.The UWB pulse Doppler radars provide high resolution range-time-frequency information. It is bestowed with advantages of low …

    utk-theses Repository record for Noncontact Vital Signs Detection (opens in a new tab)

Page 1 of 3