Results 1 to 20 of 28 for “"Photoplethysmograph,"”
-
Equivalence testing for identity authentication using pulse waves from photoplethysmograph
Photoplethysmograph sensors use a light-based technology to sense the rate of blood flow as controlled by the heart’s pumping action. This allows for a graphical display of a patient’s pulse wave form and the description of its key features. A person’s pulse wave has been proposed as a tool in a …
-
Female sexual arousal disorder subtypes : differentiation via laboratory-induced hyperventilation
… arousal was measured via the vaginal photoplethysmograph and subjective arousal was measured via self-report questionnaires. LIH differentiated women with FSAD from controls, with LIH increasing physiological arousal in the control group but having no significant effect in the …
-
Physiological sensor.
… research, various physiological signals, such as Photoplethysmograph (PPG), Galvanic Skin Response (GSR) and Skin Temperature (SKT), are measured by different types of medical sensor equipment. However, the sensors are intrusive and the patients must endure some discomfort when encountering these …
-
Heart rate estimation using wrist-acquired photoplethysmography under different types of daily life motion artifact
… physical and mental condition. Reflective wrist photoplethysmograph (PPG), obtained by a watch or wristband, can provide a natural and unconstrained way for daily life heart rate monitoring. However, reflective wrist PPG often suers from poor signal quality and various distortions due to daily …
-
The effects of sympathetic activation via acute exercise on physiological and subjective sexual arousal in women
… was measured physiologically with a vaginal photoplethysmograph and subjectively with a self-report rating scale. Acute exercise increased both vaginal pulse amplitude and vaginal blood volume responses to erotic stimuli but not to neutral stimuli. Subjective perceptions of sexual arousal …
-
Photoplethysmorgraph-derived respiration
… heart rate and respiratory rate using the photoplethysmograph (PPG) signal is rapidly growing. The main objectives of the thesis is to design a PPG hardware an ear clip sensor and analog processing circuit -- to comprise respiration related information and build a software using …
-
Category-Specificity of Women’s Sexual Arousal Across the Menstrual Cycle
… on the specificity of genital (using vaginal photoplethysmograph) and subjective sexual arousal. Cycle phase at the time of first testing was counterbalanced; however, no effect of order was observed. Inconsistent with the ovulatory-shift model, the predicted mid-cycle shift in preferences for …
-
Methodological Factors Impacting Sexual Concordance in Women
… and vaginal vasocongestion (using the vaginal photoplethysmograph; VPP) to investigate potential differences in vulvar and vaginal concordance. Twenty-five women viewed two erotic films that differed in sexual activity content (foreplay and intercourse) while their genital and subjective …
-
Development of a practical and effective technique to determine the complete level of autonomic neural activity during stress
… yield accurate results. A method which uses a Photoplethysmograph to measure blood volume in the fingertip was selected. A lap-top computer with Lab VIEW software was used to acquire, display, store and process that data. An experimental protocol which was designed to change the stress level in …
-
An investigation of remote non-contact photoplethysmography and pulse oximetry
… of non-contact remote pulse oximetry and photoplethysmography. A thorough description is given of the technique of pulse oximetry along with some physiological effects and some characteristics of light-tissue interaction that underlie pulse oximetry. A device is then described that is …
-
Evaluating the Pulse Sensor as a Low-Cost and Portable Measurement of Blood Pulse Waveform
… compliance. The Pulse Sensor, a low-cost photoplethysmograph, measures green light reflection in the finger and generates output, which is indicative of blood flow and can be read by the low-cost Arduino UNO™. The Pulse Sensor code was modified to increase the sampling frequency and to …
-
Deep learning-based signal processing approaches for improved tracking of human health and behaviour with wearable sensors
… our ‘time series-to-time series GAN’, which maps photoplethysmograph data to blood pressure measurements. Importantly, we denoise artefact-laden biosignal data to a competitive standard using a custom objective function and novel application of GANs. These deep learning methods help to produce …
-
Παρεμβατικό πρόγραμμα αγωγής και προαγωγής υγείας – διαχείρισης του στρες – εγκατάστασης υγιεινών συμπεριφορών δια της Πυθαγορείου Αυτογνωσίας σε μαθητές προσχολικής ηλικίας
… Ηλικία (ΚΕΣΠΗ), καθώς και μια συσκευή PPG (photoplethysmograph). Επιπλέον, λήφθηκαν τα δημογραφικά δεδομένα του κάθε παιδιού (φύλο, ηλικία). Για τη στατιστική ανάλυση των δεδομένων του δείγματος, χρησιμοποιήθηκαν μέθοδοι επαγωγικής και περιγραφικής στατιστικής. Αποτελέσματα: Με τη λήξη του …
-
The effect of differentiation technique utilized in continuous noninvasive blood pressure measurement
… physiological electrocardiograph (ECG), photoplethysmograph (PPG), and continuous tonometric blood pressure data; applying the algorithm described by Fung to calculate arterial blood pressures from pulse transit time, and investigating an improvement to this algorithm; applying several …
-
The endocannabinoid system and female sexual arousal
… all three studies was measured via the vaginal photoplethysmograph. Although the results of Experiment 1 did not reveal an association between endocannabinoid levels and female sexual arousal, the results of Experiment 2 revealed a significant relationship, whereby increases in both …
-
The effects of anxiety on arousal in sexually dysfunctional women
… were measured physiologically with a vaginal photoplethysmograph, and subjectively with a self-report rating scale. As predicted, functional women showed significantly greater physiological sexual arousal than dysfunctional women in both the neutral-erotic and anxiety-erotic conditions. …
-
Genital and subjective sexual arousal in women : effects of menopause, sympathetic nervous system activation, and arousal disorder
… (3) the diagnostic utility of the vaginal photoplethysmograph (VPP); and (4) the relationship between laboratory-based and at-home sexual arousal. Experiment 1 found no significant differences in genital or subjective sexual arousal between 25 premenopausal, 25 postmenopausal, and 21 …
-
The modification of dysfunctional patterns of sexual arousal through false physiological feedback and sympathetic activation
… was measured physiologically with a vaginal photoplethysmograph, and subjectively with a self—report rating scale. All subjects (1) viewed stimulus series 1 and rated their sexual arousal, (2) received the feedback condition and rated their expectations, and finally, (3) viewed stimulus …
-
Monitoring and analysis of antenatal and postnatal changes in maternal vital signs
… was used to assess beat-by-beat quality in the photoplethysmograph (PPG) waveform obtained from the pulse oximeter. The resulting signal quality index enabled the exclusion of poor-quality sections and their associated measurements of heart rate and peripheral oxygen saturation. A robust …
-
Computational Modeling Systems for the Development of Remote Monitoring Medical Devices
… and device specific factors on extracting photoplethysmographic waveforms, ultimately for use in remote blood pressure monitor. A computational framework for a multi-modal optical and fully-insertable glucose biosensor was developed via Monte Carlo modeling and Finite Element Method. The …