Results 1 to 14 of 14 for “"Physiological Equivalent Temperature (PET)"”
-
Influencia del arbolado urbano en el confort térmico en espacios abiertos. Caso de estudio en Bogotá D.C. (Colombia)
… of the growing accelerate and the increasing temperature, by the global warming. At each place, it was analyzed coverage evolution in 78.5 ha, period 2010-2017, using ArcGIS 10.1 and it was compared with its thermal comfort mainly Physiological Equivalent Temperature (PET), using RayMan Pro …
-
Índice ambiental urbano (IAU): uma contribuição ao estudo do planejamento e do conforto térmico em espaços abertos
… comfort analysis in open spaces was performed by Physiological Equivalent Temperature (PET) with the ENVI-met© program. Artificial intelligence (RNA) was used to estimate the PET index values and the microclimatic variables at the urban level. Finally, a numerical index was elaborated through …
-
Investigation of a performance-based parametric canopy
… the assessment of the quantitative objectives Physiological Equivalent Temperature (PET) and Useful Daylight Iluminance (UDI). Keywords: Complex Surfaces. Parameterization. Simulation based Optimization. Luminous and thermal performance.
-
Ανάπτυξη μεθοδολογίας και εφαρμογές για την αξιολόγηση των βιοκλιματικών συνθηκών υπαίθριων χώρων με διαφορετική διαμόρφωση
… to evaluate human thermal comfort and stress Physiological Equivalent Temperature (PET) index was used. The major PET calculations were made using RayMan Pro software. Seven different types of open spaces were selected for methodology application: a) reference space, b) building atrium, c) …
-
Calibração do índice de conforto térmicotemperatura fisiológica equivalente (pet) paraespaços abertos do município de Belo Horizonte, MG
… to calibrate the thermal comfort index known as physiological equivalent temperature (PET) for open spaces in the city of Belo Horizonte - MG. Tasks were conductedthrough the inductive experimental method. A population of adults who are healthy and acclimated to the climatic conditions of the …
-
Dinâmica climática e comportamento térmico em distintas local climate zones em uma cidade tropical costeira
… urban spaces on the surface and mean radiant temperature; and thermal comfort in different LCZs. The seasonal variability of the UHI was analyzed based on the collection of climatic data during summer and winter under "ideal weather conditions". The results showed two thermal behaviors …
-
Outdoor thermal comfort and airflow in relation to urban form in Amman, Jordan: A residential setting analysis
… effect of meteorological parameters (e.g., air temperature, wind speed and relative humidity) on the built environment, in which it is used to simulate and evaluate proposed scenarios to find out the best configuration in terms of thermal comfort and airflow. A validation study was performed on …
-
Investigating the Interdependent Influence of Multiple Environmental Features of Urban Green Spaces on Human Thermal Comfort at Microscale Using a Multi-parameter Approach
… parameters and biometeorological index -- Physiological Equivalent Temperature (PET). PET values in this research are calculated using the RayMan model. This thesis comprises three independent studies on the interdependent influence of various environmental features of UGS on human thermal …
-
Real-time monitoring, short-term predictions, and climate projections of indoor human thermal comfort using low-cost sensors and artificial neural networks
… physiologisch äquivalente Temperatur (engl.: „physiological equivalent temperature“, PET, °C). Des Weiteren präsentieren die MoBiMets die aktuellen Werte auf dem integrierten Display, und übertragen die Daten in Echtzeit an eine Datenbank, um das Echtzeit-Monitoring der thermischen Bedingungen …
-
Using Urban Green Systems as an Approach for Future Climate Change Adaptation in London
… outdoor thermal comfort was measured based on physiological equivalent temperature (PET) as a reference to evaluate modification benefits towards outdoor comfort level. These results confirmed that, across the three different climatic scenarios – 2018, the 2050s and the 2080s, for best thermal …
-
Μικροκλιματικό - βιοκλιματικό περιβάλλον αστικών υπαίθριων χώρων σε συνθήκες μεσογειακού κλίματος
… were defined different acceptable ranges of air temperature for each seasonal period. Results showed that despite the fact that the microclimatic conditions that occur during the cool period approach better the acceptable thermal environment of humans, however, it was ascertained a better …
-
Proposition d'indicateurs de confort thermique et estimation de la température radiante moyenne en milieu urbain tropical. Contribution à la méthode nationale d'évaluation des ÉcoQuartiers
… notre choix sur deux indices pertinents : la PET et l’UTCI. Le confort thermique en milieu urbain tropical est fortement affecté par la température radiante moyenne extérieure (Tmrt), qui est un paramètre physique difficilement caractérisable, aussi bien en termes de mesures que de …
-
Effets de la morphologie urbaine et de la végétation sur le microclimat à Beyrouth
… étroits.En outre, l’utilisation de l’indice PET a permis de mettre en évidence l’impact du stress thermique sur les résidents. Les valeurs élevées de PET observées à Kaskas et Furn El-Hayek classent ces zones comme « très chaudes » à « extrêmement chaudes » lors des pics estivaux, soulignant …
-
Increasing heat waves require human-biometeorological analyses on the planning-related potential to mitigate human heat stress within urban districts
… with daily peak values of the near-surface air temperature Ta,max ≥ 5 K above the mean daily Ta,max for the normal climate period 1961 to 1990 was identified as a HW. The investigation period covers the years 1951 to 2011 at least. For statistical HW analyses, quality-controlled daily Ta,max …