Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 51 for “"Physiological motion"”

  1. Doppler radar sensing of fish physiological motion

    … to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across varied fish body shapes and sizes, ranging from 0:1 to 1:3m in snout to tail length. Monitoring experiments were conducted with eleven tilapia and three sturgeons to …

    hawaii Repository record for Doppler radar sensing of fish physiological motion (opens in a new tab)

  2. Sensing human physiological motion using millimeter wave radar.

    … has been developed to detect the presence and motion of a wide array of objects, vehicles, and living beings. With the advent of small-scale, portable, affordable radar sensors, biological radar sensing has opened a new field of opportunity for healthcare applications such as vital signs …

    baylor Repository record for Sensing human physiological motion using millimeter wave radar. (opens in a new tab)

  3. Coil load changes for physiological motion acquisition in cardiac magnetic resonance imaging

    En imagerie par résonance magnétique cardiaque et thoracique, les mouvements cardiaques et respiratoires sont enregistrés avec des capteurs tels que les capteurs ECG et les ceintures respiratoires pour synchroniser les acquisitions et pour pratiquer des corrections rétrospectives des images. Le …

    star-france Repository record for Coil load changes for physiological motion acquisition in cardiac magnetic resonance imaging (opens in a new tab)

  4. Model based force control for soft tissue interaction and applications in physiological motion compensation

    L'introduction de systèmes robotisés dans les salles opératoires a fait évoluer la chirurgie moderne, ouvrant aux chirurgiens de nouvelles possibilités. La présence de tels systèmes en salle opératoire croît chaque année. Les progrès des robots médicaux sont étroitement liés au développement de …

    star-france Repository record for Model based force control for soft tissue interaction and applications in physiological motion compensation (opens in a new tab)

  5. An electromechanics four-chamber heart model for cardiac resynchronisation therapy response prediction and optimisation

    … as a key feature for reproducing the patient’s physiological motion (Chapter 5). In Chapter 6, electrical activation and contraction of the whole heart are simulated, together with the effect of the pericardium on the atria and coupling with a closed-loop model for the systemic and pulmonary …

    kings Repository record for An electromechanics four-chamber heart model for cardiac resynchronisation therapy response prediction and optimisation (opens in a new tab)

  6. Home healthcare using ubiquitous computing and robot technologies

    … Wearable units are developed to collect physiological, motion and audio signals through non-invasive wearable sensors and provide contextual information in terms of the resident's daily activity and location in the home. This enables healthcare professionals to study daily activities, …

    okstate Repository record for Home healthcare using ubiquitous computing and robot technologies (opens in a new tab)

  7. Subject isolation and non stationary clutter rejection using RF backscatter—tag radar

    … radar can be used for remote monitoring of physiological motion for humans or animals, but suffers from limitations in selectivity, clutter rejection, subject isolation and identification. The research presented in this dissertation proposes a solution to this problem by placing passive …

    hawaii Repository record for Subject isolation and non stationary clutter rejection using RF backscatter—tag radar (opens in a new tab)

  8. Design and Development of a 1 Degree of Freedom (1-DOF) Real Time Nozzle Height Compensation System Capable of Adjustment for Substrate Topology and Motion to be Used in in-situ Bioprinting

    … stationary, breathing, and heartbeat simulated physiological motion profiles. The proposed design demonstrated real time adaptive nozzle height compensation in all scenarios on smooth and organic topological substrates, while maintaining integrity of the printed structure. This capability …

    wfu Repository record for Design and Development of a 1 Degree of Freedom (1-DOF) Real Time Nozzle Height Compensation System Capable of Adjustment for Substrate Topology and Motion to be Used in in-situ Bioprinting (opens in a new tab)

  9. ACQUISITION, PROCESSING, AND ANALYSIS OF DIFFUSION TENSOR IMAGING AND ATROPHY MRI IN THE INJURED PEDIATRIC SPINAL CORD

    … of pediatric spinal cord data, including physiological motion, low signal-to-noise, thermal noise and image artifact, and cumbersome measurements of cord morphology. In this work, a complete pipeline for the acquisition and analysis of both functional DTI data and high resolution …

    temple Repository record for ACQUISITION, PROCESSING, AND ANALYSIS OF DIFFUSION TENSOR IMAGING AND ATROPHY MRI IN THE INJURED PEDIATRIC SPINAL CORD (opens in a new tab)

  10. Developing Wavefront Shaping Techniques for Focusing through Highly Dynamic Scattering Media

    … constructive interference.However, due to physiological motion, scattering of light in tissue is deterministic only within a brief speckle correlation time. In in vivo soft tissue, this speckle correlation is on the order of milliseconds. Because wavefront shaping relies on deterministic …

    wustl Repository record for Developing Wavefront Shaping Techniques for Focusing through Highly Dynamic Scattering Media (opens in a new tab)

  11. Biomechanics and Fracture Repair of the Equine Accessory Carpal Bone Using Two Cortical ‎Screws in Lag Fashion Compared with an X-Plate and One Cortical Screw in Lag Fashion‎

    … the accessory carpal bone exhibits independent physiological motion during carpal flexion compared to the other carpal bones. In addition, the morphology of the bone is shown to be largely consistent in horses of comparable size, which may provide a basis for the development of standardized …

    fu-berlin Repository record for Biomechanics and Fracture Repair of the Equine Accessory Carpal Bone Using Two Cortical ‎Screws in Lag Fashion Compared with an X-Plate and One Cortical Screw in Lag Fashion‎ (opens in a new tab)

  12. Extended Discrete Element Method for subject specific modelling and analysis of the ankle joint contact mechanics

    … does not offer the possibility of tracking the physiological motion of the contacting bones over time. Furthermore, time dependent properties such as viscoelasticity are often neglected within these frameworks. This thesis aims at extending the discrete element method (EDEM) to track the bone …

    whiterose Repository record for Extended Discrete Element Method for subject specific modelling and analysis of the ankle joint contact mechanics (opens in a new tab)

  13. The mobility and stability of the human knee joint

    … <p>A database of specimen-specific motion and geometry was established, based on cadaver studies. Articular contact kinematics and ligament length patterns were also quantified. In experiment, all components of passive knee movement were found to be coupled to the flexion angle, …

    oxford Repository record for The mobility and stability of the human knee joint (opens in a new tab)

  14. Automatic Quantification of Medical Image Registration Quality Using Deep Learning

    … tissue deformation caused by gravity, physiological motion, resection, or patient movement can shift surgical targets and vital organs from their planned locations. Registration algorithms can help track these deformations by aligning pre-operative, intra-operative, or follow-up scans. …

    concordia

  15. Reconstruction Tools and Techniques for Highly Accelerated MRI

    … diagnostic quality images can be considerable. Physiological motion during scan time can lead to motion artifacts that can degrade images rendering them undiagnostic. Thus much research has focused on reducing these artifacts by compensating for motion during imaging or reducing scan time. The …

    jhu Repository record for Reconstruction Tools and Techniques for Highly Accelerated MRI (opens in a new tab)

  16. TECHNICAL CONSIDERATIONS FOR 1H - MAGNETIC RESONANCE SPECTROSCOPY (1H-MRS) MEASUREMENT OF SPINAL CORD GAMMA-AMINOBUTYRIC ACID (GABA)

    … use di erent estimation methods. Furthermore, physiological motion such as breathing and pulsatile flow in the vessels that surround and flow through the spinal cord (i.e. CSF, blood) contribute to the highest levels of noise in the MRS signal. Therefore, a study that included the inves- …

    mcmaster Repository record for TECHNICAL CONSIDERATIONS FOR 1H - MAGNETIC RESONANCE SPECTROSCOPY (1H-MRS) MEASUREMENT OF SPINAL CORD GAMMA-AMINOBUTYRIC ACID (GABA) (opens in a new tab)

  17. Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion

    … with a high isotropic resolution is respiratory motion. Although a wide range of different methods to minimise res-piratory motion artefacts has been presented, irregular breathing can still lead to unacceptably long scan times and scan abortions. Respiratory motion in patients must also be taken …

    kings Repository record for Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion (opens in a new tab)

  18. NON-CARTESIAN MAGNETIC RESONANCE IMAGING STRATEGIES: IMPROVEMENTS IN ACCELERATED CARDIAC MAGNETIC RESONANCE IMAGING AND TECHNICAL CONSIDERATIONS

    … dynamic nature of the heart, together with the motion introduced by respiration, make it a challenging task to generate MRI images without motion-induced artifacts. Traditional approaches deal with physiological motion by acquiring the necessary information to create an image in segments over …

    jhu Repository record for NON-CARTESIAN MAGNETIC RESONANCE IMAGING STRATEGIES: IMPROVEMENTS IN ACCELERATED CARDIAC MAGNETIC RESONANCE IMAGING AND TECHNICAL CONSIDERATIONS (opens in a new tab)

  19. Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy

    … into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic …

    duke Repository record for Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy (opens in a new tab)

Page 1 of 3