Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"Picarro"”.
-
Autonomous 13C measurements in the North Atlantic
… thesis, a cavity ringdown spectrometer (G2131-i, Picarro, USA), which is able to measure the CO2 mole fraction and it's stable carbon isotope composition, was installed on a VOS line that regularly sails across the subpolar North Atlantic between North America and Europe. From summer 2012 to the …
-
Analyses of multi-species greenhouse gases and related tracers using novel measurements at Weybourne Atmospheric Observatory, Norfolk, UK
… Observatory (WAO), UK, as a case study. A ‘Picarro G2207-i' O2 analyser was tested in the laboratory and at WAO. The potential benefits of this analyser are reduction in calibration gas consumption and fewer drying requirements. The built-in water-correction procedure did not sufficiently …
-
Investigation of Volatile Organic Compounds Emissions in Different Stages of HVAC System
… ringdown spectroscopy instrumentation from Picarro through a four-valve switching chamber. This process allowed us to sample multipoint pollutants in mixed air, post-filter air, supply air, and return air in a frequent switching sequence. Our observations show that long-term exposure to some …
-
Understanding the impact of irrigation on CO₂ emissions from soils with different physical and chemical properties
… contains dissolved inorganic carbon (DIC). A Picarro cavity ring-down spectrometer was used to monitor changes in CO₂ production and ¹³C of the emitted CO₂ following irrigation events. Organically derived CO₂ is depleted in ¹³C compared with DIC-derived CO₂, hence δ¹³CO₂ measurement was used …
-
Investigating the impacts of building HVAC systems on aerosol composition and concentration
… aerosol mass spectrometer (HTOF-AMS), 2) three PICARRO gas concentration analyzers measuring CH4, CO, CH2O, CO2, NH3, and 3) Quant-AQ MODULAIR devices. Results from this study demonstrate that the primary source of PM in the building originates outdoors. Positive Matrix Factorization on the …
-
Using high temporal resolution δD, δ¹⁸O to determine groundwater and surface water interactions in tropical catchments
… the end of the tropical wet season 2013, two Picarro, Cavity Ring-Down Spectrometers, incorporating Diffusion Sampling units (DS-CRDS), were operated simultaneously over an extended period, to measure rainwater and creekwater isotope values at sub-minute temporal resolution. Over the series of …
-
Conteúdo iônico e razão isotópica em dois testemunhos do manto de gelo Antártico
… cavidade ressonante em um espectrômetro WS-CRDS Picarro® L2130i no Laboratório de Glacioquímica do CPC. No IC-02 a taxa de acumulação anual variou de 0,11 até 0,42 m.eq.H2O com uma média de 0,25 m.eq.H2O, já no IC-05 variou de 0,19 até 0,98 m.eq.H2O com uma média de 0,35 m.eq.H2O. No IC-02, o δD …
-
Addressing Water Resource Issues In Barbados Through An Isotopic and Atmospheric Characterization of Precipitation Variability
… study site. The samples were analyzed using the Picarro Cavity Ring Down Spectroscopy Unit-Water L1102-I through laboratories at the University of Kentucky and the University of Utah. The samples were reported in per mil and calibrated. The teleconnection (NAO, AMO, and ENSO) and other …
-
Composition of fine particles in Carlsbad Caverns National Park and implications for sources and visibility impacts
… for inorganic gases (HNO3 and NH3) and a Picarro cavity ring down spectrometer for methane (CH4). High-time resolution (6-minute) PM2.5 mass ranged up to 31.8 μg m−3, with an average of 7.67 μg m−3. The main inorganic ion contributions were sulfate (avg 1.3 μg m−3), ammonium (avg 0.30 μg …
-
Atmospheric reactive nitrogen in Rocky Mountain National Park
… with high-time resolution instruments (a Picarro cavity-ring down spectrometer and an Air Sentry ion mobility analyzer); 24-hr integrated concentrations of trace gases and PM2.5 chemical composition in RMNP were measured by URG denuder/filter systems coupled with lab analysis; wet nitrogen …
-
The validation of emission rate estimation methods
… actual emission rate. A vehicle equipped with a PICARRO methane and acetylene analyzer traversed or remained stationary within the gas plume to provide real-time concentration measurements of both gases. A 3-D sonic anemometer was used to characterize local meteorological conditions. The TRM is …
-
Identifying the source of the Gerhard Minnebron aquifer
… evaporation. The samples were analysed with a Picarro L2130-i Isotope and Gas Concentration Analyser. Stable isotopes with chemical analysis of the collected samples were successful in determining the aim of this study in identifying the source of the GMB's water. The chemical analysis was done …
-
The Ecological Applications of <i>Δ<sup>17</sup>O</i>: Validating a Novel Technique for Assessing Animal Metabolism and Water Intake
Animals obtain water via different processes such as drinking, consuming food, and through metabolic processes like at the end of the electron transport chain when atmospheric oxygen is combined with hydrogen to form ‘cytochrome oxidase water’. Assessing animal water flux and metabolism has mainly …
-
Observations of wildfire volatile organic compound emissions and urban ozone precursors
Anthropogenic emissions have and continue to degrade air quality and alter chemical regimes in the atmosphere. Emissions of greenhouse gases have increased global temperatures, contributed to increasingly arid conditions, and exacerbated wildfire seasonal lengths and intensities. Wildfires emit a …
-
Characterization of the sources and processes of ambient particulate matter with high-end mass spectrometry
… (MPSS) for aerosol size distribution, and a PICARRO instrument for greenhouse gases measurements. NOx and O3 analyzers, managed by the Ministry of Environment and Climate Change, provided the concentrations of NOx (NO + NO2) and O3 at the Demokritos Athens station. The first study of this …