Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Pick-Up coil"”
-
Human movement energy harvesting : a non-linear electromagnetic approach
… of energy harvesting from human movements. The pick-up coil to be used will be placed at a novel location within the energy harvester prototype.Through simulations and experiments, frequency responses obtained did show an increase in bandwidth which agrees with literature from nonlinear energy …
-
Measurements of the electrical resistivity of aluminum by electomagnetic induction
… magnitude and phase of the EMF induced in the pick-up coil are dependent upon the resistivity. These are compared with computed values determined for several resistivities and linearly interpolated to find two values of the resistivity of each sample--one for the magnitude and one for the …
-
Measurement of induction motor speed from induced slip frequency signal
… hence determine the motor speed is proposed. A pick-up coil is placed in close proximity to the motor and by suitable amplification and filtering of the weak slip frequency signal, the slip frequency signal component is isolated for the speed measurement. No device needs to be attached to the …
-
A search for a new phonon detector
… with incident phonon flux can be monitored by a pick-up coil coupled to a SQUID magnetometer. Time-of-flight measurements versus pressure and tuning magnetic field were made to test the detection technique and showed good agreement with the measurements of others for phonon velocity and …
-
Galvanically isolated wide-band current sensors
… precisely pulsed currents varying from DC up to frequencies as high as 100KHz and of reading current alteration rates as high as 10GA/sec. This requirement sets the sensor bandwidth specification to at least 1MHz for 5KA maximum current amplitude and resolution of 0.02%. Additionally, …
-
Remote field eddy current probes for the detection of stress corrosion cracks in transmission pipelines
… The method uses a pair of excitation and pick-up coils. The pick-up coil is located in the remote field region, usually two, three pipe-diameters away from the excitation coil. With RFEC the presence of defects is detected by the disturbance in the phase of the signal measured by the …
-
Energy Harvesting Based on Bistable Shape Memory Film Actuation
… for wearable devices require continuous power supply through batteries. However, with the increase in the number and density of electronic devices, the demand for the number of batteries will increase rapidly, which brings many severe problems such as battery recycling and waste battery …
-
Two dimensional Langmuir-Blodgett magnets
… an equivalent volume susceptibility of 6.4x10<sup>-3</sup> at 4.2 K. The signals from the multilayers were paramagnetic in nature and no evidence for a transition was found. Unfortunately the signal from a bilayer and monolayer were masked by contaminants on the substrate.<br/><br/>The …
-
A microcomputer-based instrument for the detection and analysis of precession motion : in a gas centrifuge machine
… a signal generated by a variable reluctance pick-up coil in the top of the centrifuge machine. This signal is called a Fidler signal. The initial Fidler signal triggers a counter which is clocked by a high-precision, 20.00Q000-MHZ, temperature-controlled, crystal oscillator. The contents of …
-
Development of Methods for the MR-guided Percutaneous Revascularization of Chronic Total Occlusions
… introduced into the MR signal by a small receive coil located at the distal tip of the catheter. The technique is developed theoretically and is demonstrated with a feasibility experiment. A forward-looking intravascular imaging catheter is then presented that is capable of acquiring of …
-
Micromagnetic and multiparameter measurement for microstructural material properties characterization
… the relationship between the number of turns of pick-up coils and MBN signals in both time-domain and frequency-domain is studied for the sensor coil optimization. With optimized pick-up coil, the characteristics of MBN are investigated for various mild steels with different grain sizes, carbon …
-
MEMS energy harvesters with a wide bandwidth for low frequency vibrations
… power was dependent on excitation amplitude and supplied DC voltage. The MEMS capacitive energy harvester was integrated with two impact oscillators at 18 Hz and 25 Hz for transferring energy from low frequency structural vibration with varying mechanical spectra to high frequency vibration of a …
-
Transient eddy current response due to a subsurface crack in a conductive plate
… current NDE in which a current pulse in a driver coil produces a transient field in a conductor that decays at a rate dependent on the conductivity and the permeability of the material and the coil configuration. By using transient eddy current, it is possible to estimate the properties of the …
-
AC loss in superconducting composites: continuous and discrete models for round and rectangular cross sections, and comparisons to experiments
In this work, AC loss in superconducting composites was described using both an anisotropic continuum model and a discrete model. The efforts were concentrated in three main areas. First, the eddy current coupling loss of composites with rectangular cross section was calculated using an anisotropic …
-
Wireless Power for Miniaturised Biomedical Implants
… to use a quasi-static electric field which can supply power deep inside the body. Recent developments have shown the use of the technology in shallow subcutaneous power transfer. This thesis investigates the impedance behaviour of living tissue as seen by the transmitter electrodes of an electric …
-
Microfabricated inserts for sensitivity enhancement in MAS NMR
… detectors for the NMR community. The magic angle coil spinning (MACS) approach in NMR has combined the advantages offered by a micro-coil detector and magic angle spinning (MAS) to bring about considerable improvements in sensitivity and resolution in solid-state NMR experiments. The MACS strategy …
-
Characterizing the Performance of a Ferrofluid-Based Electromagnetic Energy Harvester under Direct and Parametric Excitations
… be used to induce an electromotive force in a coil placed adjacent to the container. This process generates an electric current in the coil, and therewith, can be used to transduce external vibrations into electric energy providing a unique approach for vibration energy harvesting using …
-
Modelling and experimental studies of the magnetic properties of bulk high temperature superconductors
… of bulk, single grain high temperature superconductors (HTS), such as RE-Ba-Cu-0 [(RE)BCO] where RE refers to a rare earth element, have been performed using a modelling framework developed in this study. This modelling framework can simulate the various magnetisation processes of bulk …
-
Converse Magnetoelectric Resonators for Biomagnetic Field Sensing
… directly generates an ME voltage by mechanical coupling of the MS deformation to the PE phase. In order to achieve high field sensitivities, a magnetic bias field is required to operate at the maximum piezomagnetic coefficient of the MS phase. Additionally using mechanical resonances further …
-
Effect of the mechanical stress on the training of Nb₃Sn superconducting magnets
Les aimants supraconducteurs en Nb₃Sn à haut champ constituent une solution prometteuse pour les futurs collisionneurs de particules à haute énergie. À ce jour, de nombreux aimants supraconducteurs, imprégnés avec une résine époxy, ont été testés. Les conditions extrêmes en termes de courant, champ …