Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"PiezoFlow"”.
-
Comparison Of Root Canal Irrigation Systems In Reducing Intracanal Microorganisms Using Saline-An In Vitro Study
… of four root canal irrigation systems, Endovac®, PiezoFlow™, EndoActivator® and traditional needle irrigation using saline as an irrigant. Seventy-five, single canal, extracted, mature teeth were selected. Teeth were standardized to canal lengths of 15 mm and instrumented to Master Apical File …
-
Evaluation of ultrasonic irrigation systems for debris and smear removal in root canals : a scanning electron microscope study
… with a 30 gauge side vented needle, the PiezoFlow Ultrasonic irrigation system, and the VPro StreamClean Ultrasonic irrigation system. In all experimental groups, 15 mL of 3% sodium hypochlorite was used after instrumentation. Both ultrasonic systems were set at a flow rate of 15 mL/min …
-
A Comparative Study of Intraradicular Enterococcus Faecalis Biofilm Removal with Three Root Canal Treatment Systems: A Scanning Electron Microscopy Evaluation
… of three root canal treatment systems: ProUltra® PiezoFlow™, traditional needle irrigation, and the GentleWave® system in an ex-vivo benchtop study. Twenty-four extracted maxillary and mandibular molars were selected. Teeth were all instrumented to a master apical file size #25 with 4% taper. …
-
The effect of agitation on the penetration depth of sodium hypochlorite into dentinal tubules.
… of 6% NaOCl using the EndoActivator®, ProUltra® PiezoFlow™ and EndoVac® and to compare them with the standard side-vented ProRinse® needle. Methods: Sixty extracted anterior teeth with single canals were accessed conventionally, the pulp tissue removed and canal patency verified using minimal …
-
Effectiveness of irrigation methods in removing materials of different size and density from the apical root canal of a mandibular molar – an in vitro study
… of 5 and 15 mL/min (2 minutes), and the ProUltra PiezoFlow ultrasonic irrigation system at flow rates of 0 and 15 mL/min (1 minute) resulting in seven experimental irrigation groups. For each material, each irrigation group was repeated 10 times, five in horizontal and five in vertical canal …
-
Evaluation of the effectiveness of two irrigation systems in reducing bacterial load in root canals in vitro by quantitative real-time polymerase chain reaction
… instrumented into size #15/.04 (GW) and #35/.04 (PiezoFlow group) under needle irrigation with sterile water. The teeth were then cleaned either with GentleWave System or ProUltra PiezoFlow Active Ultrasonic System (Dentsply Tulsa, Tulsa, OK) using 3% NaOCl, 8% EDTA and sterile water as irrigants. …
-
Effectiveness of different irrigation protocols in removing calcium hydroxide from simulated internal root resorptions
… (DNI) at 5 ml/min, EndoActivator (EA), PiezoFlow (PF) at 15 ml/min and GentleWave system (GW) with distilled water as irrigant were used to remove Ca(OH)₂ from the root canal system and resorptions at manufacturer recommended maximum irrigation times. 36 groups (n=10) were established. …