Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Pipe configuration"”

  1. Novel pipe configuration for enhanced efficiency of vertical ground heat exchanger

    In this research, a novel U-Tube pipe configuration, consisting of a single U-Tube pipe with two outer fins, was proposed to enhance the thermal efficiency of the vertical ground heat exchanger (VGHE). The ground thermal behavior at and around the VGHE were studied for both conventional single …

    uvic Repository record for Novel pipe configuration for enhanced efficiency of vertical ground heat exchanger (opens in a new tab)

  2. Characterization of two-phase flow in a typical metrological test flow loop.

    … location to another within a flow loop. As the pipe geometry and configurations may vary for different testing laboratories and on the field, proper understanding of effect of geometrical variances on multiphase flow behaviour is deemed important for proper assessment of multiphase flow meter …

    cranfield Repository record for Characterization of two-phase flow in a typical metrological test flow loop. (opens in a new tab)

  3. Development, model validation, and preliminary experimental verification of an FEA program for structural analysis of casing in casing for oil wells.

    Oil and gas wells rely upon long steel pipes, known as casing, that run down the depth of the well. During drilling, a section of pipe is cemented in place and another section of casing is run inside, repeating this process as necessary. This process is not 100% accurate, leading to eccentric …

    baylor Repository record for Development, model validation, and preliminary experimental verification of an FEA program for structural analysis of casing in casing for oil wells. (opens in a new tab)

  4. Intrusive sensors for two-phase flow measurements

    … At an experimental level, different physical configurations of two-phase flow have been analysed: classic vertical pipe configuration, T-shaped configuration (phase separation) and modifications in fluid properties (temperature and surface tension). The objective has been the extensive …

    barcelona Repository record for Intrusive sensors for two-phase flow measurements (opens in a new tab)

  5. A Method for Developing and Testing Nuclear Reactor Systems with Space Applications and Improving Performance of Heat Pipe Reactor Systems

    … in the operation of the world’s first heat pipe reactor system, and the world’s first reactor system to produce electricity with Stirling engines. In the process of concept development, the author identified an opportunity to advance the state-of-the-art in heat pipe engineering, and …

    utk-theses Repository record for A Method for Developing and Testing Nuclear Reactor Systems with Space Applications and Improving Performance of Heat Pipe Reactor Systems (opens in a new tab)

  6. Investigation of Pumping and Piping System Design for Commercial Ground Source Heat Pumps

    … included both direct and reverse return systems, pipe sizing criteria, central and distributed pumping, and a combined central with distributed pumping, the effects of differential temperature set point, and differential pressure set point. This study also compared the traditional two-pipe …

    okstate Repository record for Investigation of Pumping and Piping System Design for Commercial Ground Source Heat Pumps (opens in a new tab)

  7. The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters

    … least of which is the flow condition inside the pipe. It has been shown that disturbances in the velocity profile affects the accuracy of a magnetic flow meter (Luntta, 1998). Accordingly, manufacturers of magnetic flow meters give installation guidelines. These guidelines help prevent the user …

    utahstate Repository record for The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters (opens in a new tab)

  8. Mathematical modelling and optimisation of the formulation and manufacture of aggregate food products

    … and packaging. Three different conveying rig configurations were employed; a straight pipe, a rig consisting two 45° bends and one with 90° bend. It was observed that the least amount of breakage occurred in the straight pipe while the most breakage occurred at 90° bend pipe. Moreover, lower …

    cork Repository record for Mathematical modelling and optimisation of the formulation and manufacture of aggregate food products (opens in a new tab)

  9. Modelling and testing of a low temperature solar organic rankine cycle power plant.

    … model involved 14 working fluids and three plant configurations. The solar field model employed ethylene glycol water as the heat transfer fluid and involved a 9-collector solar field and a 180-collector solar field. An evaporator model was developed based on a counter flow double pipe …

    ukzn Repository record for Modelling and testing of a low temperature solar organic rankine cycle power plant. (opens in a new tab)

  10. Multyphase fluid hammer : modeling, experiments and simulations

    … by the discharge of a pressurized liquid into a pipeline kept under vacuum conditions. This ow configuration induces several multiphase phenomena such as cavitation and gas desorption that cannot be ignored in the water hammer behavior. The motivation of this research work comes from the liquid …

    coruna-masters Repository record for Multyphase fluid hammer : modeling, experiments and simulations (opens in a new tab)

  11. Aerothermal performance of fan outlet guide vanes in modern geared turbofan engines

    … is investigated. The proposed idea is to have pipes transport a cooling fluid from the generator to the OGV in order to cool down the generator. The require ment on this cooling system is the ability to reject 20 kW of heat at a minimum pressure drop in the pipes. This problem is tackled by …

    chalmers Repository record for Aerothermal performance of fan outlet guide vanes in modern geared turbofan engines (opens in a new tab)

  12. Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique

    … between the acoustic transducer and the pipe have an important influence on the measurement accuracy. In this work, the influence of the flow field on the accuracy is of great importance. To estimate the uncertainties of the acoustic discharge measurement for disturbed flow fields, …

    epfl Repository record for Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique (opens in a new tab)

  13. Large eddy simulations of turbulent flows on graphics processing units: application to film-cooling flows

    … it is important. Fundamentally, a film-cooling configuration is an inclined cooling jet in a hot cross-flow. A known problem in the film-cooling method is jet lift-off, where the jet of coolant moves away from the surface to be cooled due to mutual vortex induction by the counter-rotating vortex …

    uiuc Repository record for Large eddy simulations of turbulent flows on graphics processing units: application to film-cooling flows (opens in a new tab)

  14. Experimental and Numerical Study on Full-Scale Precast Steel Fibre-Reinforced Concrete Pipes

    Reinforced concrete (RC) pipes are widely used as open channels (non-pressurized pipes) for sewage and storm water conveyance. RC pipes have generally achieved a reliable long-term performance. Depending on multiple parameters (e.g. pipe diameter, pipe wall thickness, required strength, etc.) the …

    uwo Repository record for Experimental and Numerical Study on Full-Scale Precast Steel Fibre-Reinforced Concrete Pipes (opens in a new tab)

  15. Mechanistic Framework for Risk Assessment of Cast Iron Water Main Fractures due to Moisture-Induced Soil Expansion

    … risk of failure due to aging cast iron pipes. For instance, of the 650,000 kilometers of cast-iron pipes in active service in the United States and Canada, more than 80% are beyond their intended service life. These aging and deteriorated pipes are failing at an alarming rate (22 breaks …

    waterloo Repository record for Mechanistic Framework for Risk Assessment of Cast Iron Water Main Fractures due to Moisture-Induced Soil Expansion (opens in a new tab)

  16. Use of thermo-active piling for slope stabilisation

    … up to 50-g suggest that when an appropriate pipe configuration is designed, the heating system is capable of generating a turbulent flow regime within the water circulation pipes, hence maximising the convective heat transfer mechanism. The second device consists of a large direct shear box …

    dundee Repository record for Use of thermo-active piling for slope stabilisation (opens in a new tab)

  17. Study of combined structure of geo-heat exchangers

    A geo heat exchanger (GHE) utilises a pipe configuration, buried in the ground, to harvest geothermal energy at shallow depths. A GHE could be used in heating and cooling systems as the ground temperature is normally higher than the average air temperature in winter and lower in summer. This …

    adelaide Repository record for Study of combined structure of geo-heat exchangers (opens in a new tab)

  18. Optimizing the performance of a spiral water wheel pump

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2023-04-12 without embargo terms

    uiuc Repository record for Optimizing the performance of a spiral water wheel pump (opens in a new tab)