Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Pixelated detector"”
-
Design and Characterization of Systems for Direct Spatial Imaging of Low-Energy Gamma-Radiation Sources
… which used collimation in front of a small CdTe detector, and a pixelated pinhole imager, using a pinhole mask in front of a pixelated CZT detector. Low energy gamma rays are notoriously hard to detect and image, so differing collimation or masking schemes as well as varying imaging techniques …
-
Design of a Novel Readout ASIC for X-ray Diffraction Experiments at High-Energy Synchrotron Light Sources
… requirements of the X-ray Integrating Detector (XIDer) project. XIDer is committed to the design of a 2D hybrid pixelated detector for X-ray diffraction experiments at accelerator-based fourth-generation X-ray sources like the European Synchrotron Radiation Facility (ESRF). The …
-
PHASE RETRIEVAL WITH 4D-STEM: LIMITS ON SENSITIVITY, RESOLUTION, AND SPEED
… Recent advances in segmented and pixelated detectors have driven the development of 4D-STEM. This approach captures a full diffraction pattern at each scanning position, offering a significant enhancement in phase retrieval applications such as magnetic imaging and super-resolution …
-
TECHNIQUE ADVANCES AND APPLICATIONS OF CRYO-ELECTRON-MICROSCOPY FOR THE STUDY OF VITRIFIED BIOLOGICAL SYSTEMS
… images. The implementation of tcBF-STEM with a pixelated detector optimized for STEM is demonstrated, along with the extraction of probe aberration information using tcBF imaging. Notably, tcBF-STEM enables the retrieval of information beyond the real-space scanning Nyquist limit, effectively …
-
Material uniformity of cadmium zinc telluride in gamma-ray imaging detectors
… telluride (CZT) crystals in gamma-ray imaging detectors is examined using several existing techniques and a new technique called thermally stimulated current (TSC) imaging that has been developed for this dissertation. The TSC imaging model, simulations, and experimental demonstrations are …
-
4D Scanning Transmission Electron Microscopy Analysis of Molecular and Medium Range Order in Semiconducting Polymers and Metallic Glasses
… of an electron microscope pixel array detector (EMPAD). The pixelated detector allows the collection of highly localized diffraction pattern at low current, with high speed and dynamic range, thus minimizing sample damage. P3HT and P3HT: PCBM systems were analyzed via variance, angular …
-
Development and characterization of a tunable ultrafast X-ray source via Inverse-Compton-Scattering
… The emitted X-ray spectra were detected with a pixelated detector of 1024 by 256 elements (each 26μm by 26μm) to achieve an unprecedented spatial and energy resolution for a full characterization of the emitted spectrum to reveal parameter influences and correlations of both interacting beams. …
-
Advanced detection in Lorentz microscopy: pixelated detection in differential phase contrast scanning transmission electron microscopy
… where instead of a segmented (annular) detector, a pixelated detector was used to measure the deflection of the scanning transmission microscopy (STEM) probe due to the in-plane integrated magnetic induction. Computer vision algorithms were researched to find an efficient, noise-robust …
-
Application and development of advanced Lorentz microscopy techniques for the study of magnetic nanostructures
… and detect the electron beam across the detector with respect to time. We are coupling this with a novel pixelated detector on the TEM in the form of a Medipix/Timepix chip capable of microsecond exposure times without adding noise. Running this detector in integral mode and allowing for …
-
Optimized PET module for both pixelated and monolithic scintillator crystals
… scintillator crystal geometry: the segmented or pixelated and the monolithic approach. Depending on the cost, spatial resolution and time requirements of the PET module, one can choose between one or another. The pixelated crystal is the most extensive configuration on TOF-PET scanners as the …
-
Simulation and validation of charge carrier drift in pixelated microstructured semiconductor neutron detectors
… Micro-structured Semiconductor Neutron Detector (MSNDs) bump bonded onto a Timepix pixelated readout chip. The device serves as a combined neutron and photon imager with a 256x256 pixel array, using per-pixel time-over-threshold (ToT) energy deposition. The X-MSND design has produced …
-
Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe
… been considerable interests in nuclear radiation detectors for national security and nuclear safeguard including monitoring special nuclear materials and nuclear waste characterization, for medical imaging devices using nuclear medicine such as positron emission tomography (PET), and for NASA …
-
Développement de spectro-imageurs X durs à haute densité de pixels pour l'imagerie directe de sources astrophysiques et des éruptions solaires au-delà de 30 keV
Des télescopes spatiaux focalisant des rayons X durs jusqu'à 100 à 200 keV apporteraient des réponses majeures pour la compréhension des phénomènes les plus violents et énergétiques de l'univers, dans les supernovae ou plus proche de nous dans les éruptions solaires. Des techniques de super-miroirs …