Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Planar Detector"”
-
Investigation of Advanced Dose Verification Techniques for External Beam Radiation Treatment
… may be accomplished using entrance or exit detectors. The objective of this project is to investigate a novel entrance detector designed for in vivo dose verification. This thesis is separated into three main investigations, focusing on a prototype entrance transmission detector (TRD) …
-
Improving the spatial resolution and image noise in densily pixilated detectors for positron emission mammography
In positron emission mammography, the use of planar detector limits the angular coverage and introduces more noise than conventional positron emission tomography. We first studied the sampling artifacts introduced from the use of discrete crystals. The images are reconstructed by back-projecting …
-
An experimental investigation to assess the feasibility of imaging medical radioisotopes with the ProSPECTus Compton Camera
… system configured with segmented solid state detectors, for the purpose of alleviating the limitations of conventional Single Photon Emission Computed Tomography (SPECT) systems. The ProSPECTus system consists of a Si(Li) and HPGe planar detector housed in a magnetic field compatible custom …
-
A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction
… are capable of simple point -dose or coarse planar characterization of radiation doses but are unable to provide a full three-dimensional (3D) representation of these complex dose distributions. This project proposes the development of a novel radiation detector capable of measuring and …
-
Quantitative optical probing of plasma accelerators
… just from a single 2D image captured by a planar detector. Numerical tests show that it can retrieve up to ten sets of 2D spectral profile just from a single image. The retrieved signal is also robust for further post-processing.</p> <p>The third method is based on a numerical technique to …
-
Quasi-monoenergetic laser-plasma acceleration of electrons beyond 1 GeV at the Texas Petawatt Laser
… filters distributed strategically on a planar detector, high-fidelity x-ray images were reconstructed, and iso-intensity contours subsequently defined. I demonstrate how x-ray spectra may be calculated on such contours and used to produce a 3D representation of the x-ray spectrum. This …
-
An Investigation of Broadband Current Preamplification for Obtaining Simultaneous High-Resolution Energy and Time Information from Nuclear Radiation Detectors
… involving linear gating of the amplified detector current pulse, a review of related technology is presented and a simple Rte filter for use in a gated system is discussed.</p> <p>A three-stage preamplifier having a current gain of 8000 was constructed to experimentally verify the …
-
Unipolar Charge-Sensing for Evaporated Large-Area Solid-State Photoconductors for Digital Radiography
… than gas, and thus, they can yield much smaller detector dimensions with unsurpassed spatial and temporal resolution. Thus far, crystalline Cadmium Zinc Telluride is the only room-temperature solid-state detector that meets the requirements for photon counting imaging. However, the material is …
-
3D detectors for synchrotron applications
3D detectors are a novel variety of photodiode radiation detector, invented by Parker, Kenney and Segal (1997). Instead of having n- and p-type contacts on the front and back surfaces of a silicon substrate, like a standard photodiode, they have columns of doped material passing through the …
-
Growth, Characterization, and Surface Modification of Gallium Telluride For Radiation Detection
Two growth methods are investigated for producing detector-grade large volume layered chalcogenide gallium telluride (GaTe) single crystals. Growth method one utilizes a graphite crucible heated within an argon environment, yielding 2" diameter ingots. The second method uses a modified vertical …
-
Investigation Of Wide Bandgap Semiconductor Devices For Radiation Detection Applications
… x-rays, gamma-rays, and neutrons. Nuclear detectors could stop these high-energy ionizing radiations, collect and transport the charges generated to an external circuit, and produce an electrical signal which is amplified by readout electronics to measure the energy of nuclear interaction. …