Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 270 for “"Planar Laser Induced Fluorescence"”

  1. Thermal boundary layer measurements using planar laser induced fluorescence.

    An experimental arrangement of toluene-based Planar Laser Induced Fluorescence (PLIF) has been developed and applied to the study of free and impinging jets formed with air. In the toluene-based PLIF experiment, the flow is seeded with toluene particles and is illuminated using a laser light sheet. …

    baylor Repository record for Thermal boundary layer measurements using planar laser induced fluorescence. (opens in a new tab)

  2. Quantitative Hypersonic Flow Measurements using Planar Laser-Induced Fluorescence

    … quantitative analysis methods for nitric oxide planar laser-induced fluorescence experiments. The methods are based on performing a spectral scan with a pulsed laser, exciting multiple nitric oxide transitions,and analyzing the resulting spectra. The nitric oxide fluorescence spectra is …

    calgary Repository record for Quantitative Hypersonic Flow Measurements using Planar Laser-Induced Fluorescence (opens in a new tab)

  3. Development of high repetition rate no planar laser induced fluorescence imaging

    … development of a MHz repitition rate pulse burst laser system. Second harmonic and third harmonic efficiencies are improved by adding a Phase Conjugate Mirror to the system. Some high energy fundamental, second harmonic, and third harmonic burst sequences consisting of 1 – 12 pulses separated in …

    ohiolink Repository record for Development of high repetition rate no planar laser induced fluorescence imaging (opens in a new tab)

  4. Hydroxyl-Radical Planar Laser-Induced Fluorescence Imaging of Turbulent Supersonic Combustion

    … flow from non-intrusive hydroxyl radical (OH) planar laser-induced fluorescence (PLIF) images are presented. The OH PLIF images show instantaneous structures of turbulence in two combustor configurations at different fuel equivalence ratios in the University of Virginia Supersonic Combustion …

    calgary Repository record for Hydroxyl-Radical Planar Laser-Induced Fluorescence Imaging of Turbulent Supersonic Combustion (opens in a new tab)

  5. An Investigation of Gas Turbine Aerodynamics using Planar Laser-Induced Fluorescence (PLIF)

    … thesis describes the development of InfraRed Planar Laser-Induced Fluorescence (IR-PLIF) as an experimental technique applicable to the study of EWC and flow interactions in turbomachinery. To enable the study of EWC in the presence of purge flow a single-stage turbine facility was built and …

    bath Repository record for An Investigation of Gas Turbine Aerodynamics using Planar Laser-Induced Fluorescence (PLIF) (opens in a new tab)

  6. Planar laser-induced fluorescence of nitric oxide in isomeric butanol and butane stagnation flames

    … à trait aux émissions d'oxydes d'azote (NOx). La fluorescence planaire induite par un laser (PLIF) est utilisée pour obtenir les profils de production d'oxyde nitrique (NO) à partir de flammes de stagnation pré-mélangées de n- et iso-butanol ainsi que de nand iso-butane pour mettre en contexte les …

    mcgill Repository record for Planar laser-induced fluorescence of nitric oxide in isomeric butanol and butane stagnation flames (opens in a new tab)

  7. In Situ Flame Structure Imaging of Composite Propellants using High-Speed Planar Laser-Induced Fluorescence

    … the models themselves. Recently, high-speed OH planar laser-induced fluorescence (PLIF) imaging has been applied to AP composite propellants to determine how microscale propellant flame structure varies with propellant formulation and pressure. Propellants with monomodal AP particle size …

    purdue-thes Repository record for In Situ Flame Structure Imaging of Composite Propellants using High-Speed Planar Laser-Induced Fluorescence (opens in a new tab)

  8. Quantitative measurements of ablation-products transport in supersonic turbulent flows using planar laser-induced fluorescence

    … of the dispersion of a passive scalar using planar laser-induced fluorescence (PLIF), is applied to a Mach 5 turbulent boundary layer and a NASA Orion capsule flowfield. To enable the quantification of naphthalene PLIF images, quantitative fluorescence and quenching measurements were made in …

    texas Repository record for Quantitative measurements of ablation-products transport in supersonic turbulent flows using planar laser-induced fluorescence (opens in a new tab)

  9. DEVELOPMENT OF KRYPTON PLANAR LASER INDUCED FLUORESCENCE METHODS FOR THE MEASUREMENT OF HYPERSONIC FLOW CONDITIONS

    … this project was to develop a scalable krypton planar laser induced fluorescence flow visualization system for use on curved-surface geometries in sup- port of the hypersonic Boundary Layer Transition (BOLT) program. The system was designed to fit multiple wind-tunnel facilities, including the …

    maryland Repository record for DEVELOPMENT OF KRYPTON PLANAR LASER INDUCED FLUORESCENCE METHODS FOR THE MEASUREMENT OF HYPERSONIC FLOW CONDITIONS (opens in a new tab)

  10. High-frame-rate planar laser-induced fluorescence imaging of diesel sprays using pulse burst diagnostics

    <p>A planar laser-induced fluorescence technique for spatially and temporally resolving individual diesel fuel injection events into various gas temperatures and pressures was demonstrated. An optically accessible chamber of constant temperature and pressure was</p> <p>used to create the desired …

    iastate Repository record for High-frame-rate planar laser-induced fluorescence imaging of diesel sprays using pulse burst diagnostics (opens in a new tab)

  11. Planar Laser Induced Fluorescence Experiments and Modeling Study of Jets in Crossflow at Various Injection Angles

    Planar Laser Induced Fluorescence (PLIF) with acetone seeding was applied to measure the scalar fields of an axisymmetric freejet and an inclined jet-in-crossflow as applicable to film cooling. From the scalar fields, jet-mixing and trajectory characteristics were obtained. In order to validate the …

    ucf Repository record for Planar Laser Induced Fluorescence Experiments and Modeling Study of Jets in Crossflow at Various Injection Angles (opens in a new tab)

  12. Investigation of Turbulent Jet Mixing in Partially-Premixed Water Heater Burners Using Planar Laser-Induced Fluorescence

    … heater burner has been studied using acetone Planar Laser-Induced Fluorescence (PLIF). Baseline measurements were taken, and the effects of fuel supply pressure and orifice type on the mixing characteristics in the entrainment region have been studied. The effect of fuel supply pressure was …

    marquette Repository record for Investigation of Turbulent Jet Mixing in Partially-Premixed Water Heater Burners Using Planar Laser-Induced Fluorescence (opens in a new tab)

  13. Planar Laser-Induced Fluorescence of Formaldehyde in the Reacting Jet of a High Pressure Axially Staged Combustor

    Planar laser-induced fluorescence (PLIF) is a spectroscopic diagnostic method used widely in combustion research. In this study, imaging with formaldehyde as the tracer species was used in the diagnosis of jet engine performance at the UCF Propulsion and Energy Research Laboratory (PERL). PLIF …

    ucf Repository record for Planar Laser-Induced Fluorescence of Formaldehyde in the Reacting Jet of a High Pressure Axially Staged Combustor (opens in a new tab)

  14. Mach 1.3 wind tunnel development for acetone planar laser-induced fluorescence based density measurements of conical flow

    … and developed for experimental use with acetone planar laser-induced fluorescence (PLIF) based density measurements of a conical shock wave. The focus of this thesis is on the development on the wind tunnel, and not on the PLIF measurements. The nominal Mach 1.3 wind tunnel was based on an …

    texas Repository record for Mach 1.3 wind tunnel development for acetone planar laser-induced fluorescence based density measurements of conical flow (opens in a new tab)

  15. Establishing continuous planar laser-induced fluorescence to evaluate static mixers in conjunction with particle tracking computational fluid dynamics

    … test facility was developed to enable continuous Planar Laser-Induced Fluorescence (PLIF) for the evaluation of static mixers. By integrating an activated carbon-based filtration system, the Rhodamine 6G tracer compound was adsorbed from spent glycerol test fluid, allowing it to be recycled back …

    birmingham Repository record for Establishing continuous planar laser-induced fluorescence to evaluate static mixers in conjunction with particle tracking computational fluid dynamics (opens in a new tab)

  16. Technique for imaging ablation-products transported in high-speed boundary layers by using naphthalene planar laser-induced fluorescence

    A new technique is developed that uses planar laser-induced fluorescence (PLIF) imaging of sublimated naphthalene to image the transport of ablation products in a hypersonic boundary layer. The primary motivation for this work is to understand scalar transport in hypersonic boundary layers and to …

    texas Repository record for Technique for imaging ablation-products transported in high-speed boundary layers by using naphthalene planar laser-induced fluorescence (opens in a new tab)

  17. Acetone planar laser-induced fluorescence and phosphorescence for mixing studies of multiphase flows at high pressure and temperature

    An extension of the current acetone Planar Laser-Induced Fluorescence (PLIF) was formulated for mixing studies of fluids at subcritical and supercritical conditions. The new technique, called Planar Laser-Induced Fluorescence and Phosphorescence (PLIFP), employs the difference in the mass …

    gatech Repository record for Acetone planar laser-induced fluorescence and phosphorescence for mixing studies of multiphase flows at high pressure and temperature (opens in a new tab)

Page 1 of 14