Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"Plastic Scintillation Detector"”.

  1. Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning

    … commissioning workflows often require multiple detectors and can be time-intensive, particularly for small-field dosimetry where measurement accuracy is highly sensitive to detector characteristics. This study evaluated the performance of a plastic scintillation detector (BP-PSD) for full water …

    vcu Repository record for Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning (opens in a new tab)

  2. Systematics of cross sections for target K-vacancy production in heavy ion collisions

    … Ta. The x-ray yields were measured with a Si(Li) detector, while the projectile ions were counted in coincidence with the x-rays using a plastic scintillation detector. In addition, the amount of secondary K-shell ionization and the degree of simultaneous L-shell ionization in primary K-shell …

    tamu Repository record for Systematics of cross sections for target K-vacancy production in heavy ion collisions (opens in a new tab)

  3. Establishing a Conventional LINAC-Based Electron FLASH Beam

    … mechanism was developed around a commercial plastic scintillation detector equipped with an ultra-fast acquisition unit, display, and customizable microcontroller. Circuitry was developed to connect the acquisition unit’s output to an interface board on the LINAC, which enabled the assertion …

    vcu Repository record for Establishing a Conventional LINAC-Based Electron FLASH Beam (opens in a new tab)

  4. PROMPT FISSION NEUTRON ENERGY SPECTRUM OF n+<sup>235</sup>U

    … time-of-flight was measured with 2~m long plastic scintillation detectors. By combining the time-of-flight information with a known flight path the kinetic energy spectrum of neutrons was measured. To eliminate backgrounds various time-of-flight and energy cuts were imposed and an …

    uky-thes Repository record for PROMPT FISSION NEUTRON ENERGY SPECTRUM OF n+<sup>235</sup>U (opens in a new tab)

  5. In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy

    … This is due in part to a lack of available detectors ideally suited to perform <em>in vivo</em> dosimetry. Plastic scintillation detectors (PSDs) possess a number of dosimetric characteristics advantageous for <em>in vivo </em>dosimetry including water equivalence, real-time capability, …

    uthsc Repository record for In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy (opens in a new tab)