Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Plastic hinge length"”.

  1. Plastic hinge length in high-rise concrete shear walls

    … capacity of a concrete shear wall depends on the length of the plastic hinge. Typical building codes and several researchers recommend the use of an equivalent plastic hinge length at the base equal to half the wall length. However, the plastic hinge length is also influenced by parameters other …

    ubc Repository record for Plastic hinge length in high-rise concrete shear walls (opens in a new tab) Download PDF for Plastic hinge length in high-rise concrete shear walls (opens in a new tab)

  2. Plastic Hinging Behavior of Reinforced Concrete Bridge Columns

    … deformations generally occur over a finite hinge length. A model of hinging behavior in reinforced concrete bridge columns will help guide proportioning, detailing and drift estimates for performance-based design. Data was collected during the NEESR investigation of the seismic performance …

    ku Repository record for Plastic Hinging Behavior of Reinforced Concrete Bridge Columns (opens in a new tab)

  3. Modeling the behavior of shear-critical reinforced concrete columns under lateral loads

    … deformability of such columns, the definition of plastic hinge length was reassessed through consideration of yield penetration effects. The required confined zone in critical regions of columns and piers undergoing lateral sway during earthquakes is related to the plastic hinge length where …

    greece Repository record for Modeling the behavior of shear-critical reinforced concrete columns under lateral loads (opens in a new tab)

  4. In-Ground Plastic Hinge Analysis for Piles Used in Marine Oil and LNG Terminals

    … the current recommendations for the in-ground plastic hinge length and depth for piles in section 7 of MOTEMS for all typical soil properties and pile dimensions found in Marine Oil and LNG Terminals. The pile types considered in this analysis are 24-inch octagonal prestressed concrete piles …

    calpoly Repository record for In-Ground Plastic Hinge Analysis for Piles Used in Marine Oil and LNG Terminals (opens in a new tab)

  5. Seismic performance of full-scale reinforced concrete columns

    … among various ductility parameters. Measured plastic hinge lengths of column specimens were also affected by the shear span-to-depth ratio and axial load. The plastic hinge length of concrete columns was investigated by studying the compressive strain profile of the core concrete. An …

    texas Repository record for Seismic performance of full-scale reinforced concrete columns (opens in a new tab)

  6. Ductility of Reinforced Concrete Masonry Shear Walls

    … achieved through the development of a flexural plastic hinge at the base characterized by yielding of the vertical reinforcement. The length of the plastic hinge and the ultimate curvatures within this region are the essential parameters affecting the ductility and ultimate displacements of …

    mcmaster Repository record for Ductility of Reinforced Concrete Masonry Shear Walls (opens in a new tab)

  7. Flexure And Punching Shear Behavior Of Uhpc Elements Post-Tensioned With Unbonded Tendons

    … at the ultimate limit state as a function of plastic hinge length. The procedure for obtaining the moment-curvature-deformation response does not rely on empiricism other than what is included in the assumed material constitutive models, and provides the means to determine the variation of …

    wayne-thes Repository record for Flexure And Punching Shear Behavior Of Uhpc Elements Post-Tensioned With Unbonded Tendons (opens in a new tab)

  8. Evaluation of plastic hinge models and inelastic analysis tools for performance-based seismic design of RC bridge columns

    … notion of an equivalent region under constant plastic curvature, i.e., the plastic hinge length (Lp), has been the main approach for evaluating the inelastic response of reinforced concrete (RC) columns for seismic bridge design. Most of the proposed Lp models have been calibrated on columns …

    msu Repository record for Evaluation of plastic hinge models and inelastic analysis tools for performance-based seismic design of RC bridge columns (opens in a new tab)

  9. State of practice in seismic rehabilitation of buildings and fragility analysis of RC columns retrofitted with FRP

    … to compute the ultimate curvature and the plastic hinge length. These equations are used to compute the lateral deformation capacity of the columns in the database, obtaining good estimations. Finally, fragility curves are proposed based the results of tests included in the database. Three …

    texas Repository record for State of practice in seismic rehabilitation of buildings and fragility analysis of RC columns retrofitted with FRP (opens in a new tab)

  10. Parametric Study on the Seismic Performance of Typical Highway Bridges in Canada

    … bearing, post-yield stiffness of the bearing, plastic hinge length, and damping. For the purpose of examination, two typical reinforced concrete highway bridges located in Montreal were selected. Three-dimensional (3-D) nonlinear model the bridge was developed using SAP2000. The effects of the …

    concordia Download PDF for Parametric Study on the Seismic Performance of Typical Highway Bridges in Canada (opens in a new tab)

  11. Seismic Retrofit of Reinforced Concrete Shear Wall by Integrating Selective Weakening and Self Centering

    … to provide improve alternative for predicting plastic hinge length in rocking walls, which is critical in estimating critical concrete strain.Laboratory testing of precast rocking shear walls has been limited to rectangular cross section. This dissertation addresses the gap in literature by …

    alabama Repository record for Seismic Retrofit of Reinforced Concrete Shear Wall by Integrating Selective Weakening and Self Centering (opens in a new tab)

  12. Performance-based seismic assessment of circular concrete bridge columns reinforced with ASTM A955 duplex stainless steel

    … at various strain amplitudes and unsupported lengths to evaluate the impact of inelastic buckling. Results revealed that ASTM A955 Grade 520 bars outperformed the CSA G30.18 400W bars in terms of cycles to failure and energy dissipation, particularly at higher strain amplitudes. Building on …

    ubc Repository record for Performance-based seismic assessment of circular concrete bridge columns reinforced with ASTM A955 duplex stainless steel (opens in a new tab) Download PDF for Performance-based seismic assessment of circular concrete bridge columns reinforced with ASTM A955 duplex stainless steel (opens in a new tab)

  13. Performance-based seismic design and assessment of concrete bridge piers reinforced with shape memory alloy rebar

    … of concrete strength, bar diameter, embedment length, and surface condition. In addition, a plastic hinge length expression for SMA-RC bridge pier was developed which can be used for calculating the flexural displacement capacity and design of SMA-RC bridge pier. Using Incremental Dynamic …

    ubc Repository record for Performance-based seismic design and assessment of concrete bridge piers reinforced with shape memory alloy rebar (opens in a new tab) Download PDF for Performance-based seismic design and assessment of concrete bridge piers reinforced with shape memory alloy rebar (opens in a new tab)

  14. Strength of Prestressed Concrete Girders with Bonded and Unbonded Strands

    … the total reinforcement area. An increase in the length of the constant moment region led to an increase in unbonded strand stress and consequently the flexural strength. Comparisons of the analysis results to AASHTO LRFD Bridge Design Specifications (BDS) predictions showed that AASHTO can …

    buffalo Repository record for Strength of Prestressed Concrete Girders with Bonded and Unbonded Strands (opens in a new tab)

  15. Numerical and analytical methods to predict behavior of reinforced ductile concrete composites

    … in terms of crack progression, reinforcement plasticity, and failure mechanism is significantly different than conventional reinforced concrete. Specifically, the failure mode of flexural members is found to be predominantly through the fracture of longitudinal reinforcement rather than …

    njit Repository record for Numerical and analytical methods to predict behavior of reinforced ductile concrete composites (opens in a new tab)

  16. Αντοχή και ικανότητα παραμόρφωσης μελών οπλισμένου σκυροδέματος, με ή χωρίς ενίσχυση

    … with lap-splice of longitudinal reinforcement in plastic hinge region. In order to develop new models and check older ones, a database of more than 2800 experiments from international literature on reinforced concrete elements was created and used here. Simple equations and procedures are …

    greece Repository record for Αντοχή και ικανότητα παραμόρφωσης μελών οπλισμένου σκυροδέματος, με ή χωρίς ενίσχυση (opens in a new tab)

  17. Modeling strategies for structures using ductile concrete materials in seismic applications

    … of frame structures using HPFRCCs in potential plastic hinge region of Beams.</p><p>First, a fiber-hinge lumped-plasticity model is adopted to simulate the non-linear response of reinforced HPFRCC components and material level modeling parameters are calibrated. A simple expression for …

    njit Repository record for Modeling strategies for structures using ductile concrete materials in seismic applications (opens in a new tab)

  18. HIGH-STRENGTH STEEL BARS IN EARTHQUAKE-RESISTANT T-SHAPED CONCRETE WALLS

    … were conducted to evaluate the use of the plastic hinge model for estimating the deformation capacity of the walls and the maximum strain demands. The use of the plastic hinge model was conservative for estimating wall deformation capacity with simple rules for the plastic hinge length …

    ku Repository record for HIGH-STRENGTH STEEL BARS IN EARTHQUAKE-RESISTANT T-SHAPED CONCRETE WALLS (opens in a new tab)

  19. Blast Performance of Reinforced Concrete Columns Protected by FRP Laminates

    … 150 mm x 150 mm in cross section and 2438 mm in length. Each concrete column was reinforced longitudinally with four 10M rebars which were tied laterally with 6.3 mm closed steel hoops, spaced at 37.5 mm and 100 mm c/c, representing seismic and non-seismic column details, respectively. The …

    ottawa-retro Repository record for Blast Performance of Reinforced Concrete Columns Protected by FRP Laminates (opens in a new tab)

  20. Experimental Study on Steel-Concrete Composite NPS System Beam Column Joints Under Reversed Cyclic Earthquake Loading

    … the beam end-regions (i.e., the “critical” or “plastic hinge” length). This thesis provides a detailed discussion of the experimental outcomes and a careful analysis of the observed response mechanisms and any subsequent design implications. The results of the experimental investigation were …

    washington Repository record for Experimental Study on Steel-Concrete Composite NPS System Beam Column Joints Under Reversed Cyclic Earthquake Loading (opens in a new tab)

Page 1 of 2