COMMISSIONING AND EVALUATION OF W2 PLASTIC SCINTILLATION DETECTORS FOR CLINICAL APPLICATIONS
… to ensure the patient receives the correct dose. Plastic scintillation detectors were introduced to address the shortcomings of older detectors for small field dosimetry. This study aims to determine the effects of varying dose rates on CLR values, commission the W2 PSD for clinical application, …
-
In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy
… This is due in part to a lack of available detectors ideally suited to perform in vivo dosimetry. Plastic scintillation detectors (PSDs) possess a number of dosimetric characteristics advantageous for in vivo dosimetry including water equivalence, real-time capability, small size, and energy …
-
Analysing the impact of detector properties on pulse shape discrimination in plastic scintillation detectors using Monte Carlo simulations
… (PSD) performance of the commercially available plastic scintillator EJ-276. Plastic scintillators provide a cost-effective and physically robust alternative to conventional neutron detection technologies, such as 3He detectors, liquid scintillators, and crystal scintillators. However, previous …
-
PROMPT FISSION NEUTRON ENERGY SPECTRUM OF n+<sup>235</sup>U
… time-of-flight was measured with 2~m long plastic scintillation detectors. By combining the time-of-flight information with a known flight path the kinetic energy spectrum of neutrons was measured. To eliminate backgrounds various time-of-flight and energy cuts were imposed and an …
-
SPOT SCANNING PROTON BEAMS CHARACTERIZATION VIA PLASTIC SCINTILLATOR DETECTOR
… chambers beyond their reliable operating range. Plastic scintillation detectors offer a potential solution. Their sub-millimeter active volumes avoid the volume-averaging effects over larger chambers, and their very high temporal resolution making real-time monitoring feasible. This thesis …
-
Low-background balloon-borne direct search for ionizing massive particles as a component of the dark galactic halo matter.
… of a delayed coincidence between four ∼ 2400 cm² plastic scintillation detectors, with a total acceptance of ∼ 100 cm² sr. In order to search for ultra-slow particles which do not slow down in the IMAX telescope, the experiment contained TDCs which measured the time-delays T(i,i+1) ∈ [0.3, 14.0] …
-
ENRICHMENT DETERMINATION OF URANIUM METAL IN SHIELDED CONFIGURATIONS WITHOUT CALIBRATION STANDARDS
… predicts the time correlations expected from plastic scintillation detectors following interrogation of the uranium with a deuterium-tritium neutron generator. The simulated time correlations that best match the measured time correlations are used to estimate the actual enrichment.</p> <p>The …
-
Dosimetry and radiobiology of ultrahigh dose-rate radiotherapy delivered with low-energy x-rays and very high-energy electrons
… used in traditional radiotherapy. In this work, plastic scintillation detectors (PSDs) of various compositions were used to measure dose from both 120 kVp x-rays and 200 MeV electrons. Experiments with the shutter-controlled x-ray tube demonstrated that lead-doped polystyrene PSDs can be used as …
-
Optimization of plastic scintillator thicknesses for online beta detection in mixed fields
… have been built to optimize the thickness of a plastic scintillator, used in whole body monitor. The simulation has been performed using MCNP/X code and different thicknesses of plastic scintillators ranging from 150 to 600 um have been used. The relationship between the thickness of the …