Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Platinum coils"”

  1. Tough Macroporous Hydrogel-Fiber Composites with Thermoresponsive and Enhanced Mechanical Properties for Transcatheter Embolization

    … current gold standard for such procedures uses platinum coils, which induce thrombus formation to block blood flow. However, platinum coils are highly vessel specific, require a large inventory of coils at caregiving sites, are high in cost, cause imaging artifacts in CT scans, and require a …

    jhu Repository record for Tough Macroporous Hydrogel-Fiber Composites with Thermoresponsive and Enhanced Mechanical Properties for Transcatheter Embolization (opens in a new tab)

  2. A Shape Memory Polymer for Intracranial Aneurysms: An Investigation of Mechanical and Radiographic Properties of a Tantalum-Filled Shape Memory Polymer Composite

    … for large aneurysms is by embolization using platinum coils. However, in about 15% of the cases treated by platinum coils, the aneurysm eventually re-opens. The solution to the problem of aneurysm recurrence may be to develop more bio-active materials, including certain polymers, to use as …

    gatech Repository record for A Shape Memory Polymer for Intracranial Aneurysms: An Investigation of Mechanical and Radiographic Properties of a Tantalum-Filled Shape Memory Polymer Composite (opens in a new tab)

  3. Characterization of pressure reduction mechanism in treatment of intracranial aneurysm

    … without major surgery by placing embolization coils into the aneurysm or flow diverters across the aneurysm's neck. With these placements, blood flow into the aneurysm is immediately reduced and the aneurysm is occluded in long term. However, clinical studies showed that recurrence risk of …

    hkust Repository record for Characterization of pressure reduction mechanism in treatment of intracranial aneurysm (opens in a new tab)

  4. Pure metal resistance standards

    … of Standards. Values were assigned to these coils in 1910 on the basis of mercury ohm determinations. Since that time, it has been assumed that the average value of the best ten of these standards has remained constant. Since the relative values of these coils change but little, it is assumed …

    texas Repository record for Pure metal resistance standards (opens in a new tab)

  5. A nonlinear stress sensitivity study on role of Coil-thrombus complex in reduction of idealized cerebral aneurysm wall stresses

    … therapies using commercially available platinum coils and other liquid embolic agents have gained widespread acceptance as a preferred treatment modality over the gold standard of surgical clipping for the treatment of acute intracranial cerebral aneurysms. However, recent and ongoing …

    ohiolink Repository record for A nonlinear stress sensitivity study on role of Coil-thrombus complex in reduction of idealized cerebral aneurysm wall stresses (opens in a new tab)

  6. Product Development of a Neurovascular Embolization Device

    … for treating intracranial aneurysms is with platinum coils that are deployed to pack the aneurysm and block blood flow and prevent rupture. However, coil compaction and re-bleeding are two limitations with the coils because they have limited space filling capacity. Dr. Duncan Maitland has …

    tamu Repository record for Product Development of a Neurovascular Embolization Device (opens in a new tab)

  7. Optical Devices And Systems In Highly Nonlinear Materials And Geometries

    … of fabrication, which was based on heating using platinum coils in normal lab conditions and produced high optical quality samples with diameters ranging from 50 [mu]m to 500 [mu]m. We then developed a new method of coupling to high refractive index resonators using silicon waveguides. We …

    cornell Repository record for Optical Devices And Systems In Highly Nonlinear Materials And Geometries (opens in a new tab)

  8. Preparation of catalyst supports using chemical vapour deposition

    … problems. Attempts were made first to coat platinum coils with alumina using aluminium isopropoxide as the starting reagent. Various coil temperatures, flow rates and deposition times were used, but dense, coherent, thick deposits could not be produced. Extensive amounts of impurities were …

    city-london Repository record for Preparation of catalyst supports using chemical vapour deposition (opens in a new tab)

  9. Συγκριτική μελέτη εμβολισμού ανευρισμάτων εγκεφάλου σε σχέση με την εγκεφαλική αρτηρία στην οποία εντοπίζονται

    Backgrounds: Endovascular treatment of cerebral aneurysms has currently become the treatment of choice in both ruptured and unruptured cases. Τhe presented prospective study evaluates a 2 years’ experience using different devices and techniques in the endovascular treatment of brain aneurysms in …

    greece Repository record for Συγκριτική μελέτη εμβολισμού ανευρισμάτων εγκεφάλου σε σχέση με την εγκεφαλική αρτηρία στην οποία εντοπίζονται (opens in a new tab)