Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Polarization gating"”
-
Study on generation of attosecond pulse with polarization gating
… tunable single attosecond pulse by using polarization gating. In the experiment, we compressed ~30fs pulses from the laser amplifier down to ~6fs and characterized them. These linearly polarized pulses were converted to ellipticity varying pulses, and by exploiting the property of the …
-
Elliptically polarized light for depth resolved diffuse reflectance imaging in biological tissues
Polarization gating imaging is a popular and widely used imaging technique in biomedical optics to sense tissues, deeper volumes, and also selectively probe sub-superficial volumes. Due to the "polarization memory" effect of polarized light, elliptical polarization-gating allows access to tissue …
-
Depth-resolved measurements in multi-layer scattering media using linearly and elliptically polarized reflectance spectroscopy
… elastic scattering spectroscopy that relies on polarization gating to selectively isolate polarization maintaining photons in order to probe superficial depths. Polarization gating relies on the observation that as light travels deeper into a turbid medium and undergoes scattering, the incident …
-
Generation of intense high harmonics: i) to test and improve resolution of accumulative x-ray streak camera ii) to study the effects of carrier envelope phase on XUV super continuum generation by polarization gating
… the effect of the Carrier envelope (CE) phase on polarization gated extreme-ultraviolet (XUV) super-continuum generation. Because the challenge of making single shot experiment possible is to generate a sufficient number of photons, our setup has been built to allow generation of high order …
-
Optical-parametric-amplification applications to complex images
… primarily focused on the nonlinear processes of Polarization Gating and of Optical Parametric Amplification, one for measurement and the other for imaging purposes. For measurement, we have demonstrated a robust method of measurement to simultaneously measure both optical pulses used in a …
-
Raising the XUV Intensity towards Attosecond-Attosecond Pump-Probe Experiments
… and measure the resulting events. Different gating techniques are available to reduce the XUV pulse duration. A simulation of them was developed to compare the resulting energies and to choose the most efficient method. It calculated the pulse resulting from the gating optics, the evolution …
-
Novel methods for the characterization and control of ultrashort laser pulses
… equally important. For example, a time-dependent polarization state is necessary for generating isolated attosecond pulses (IAPs) via high-order harmonic generation using the polarization gating technique. While this method has been known for over two decades, its implementation remains …
-
Pulse compression and dispersion control in ultrafast optics
… developed a method to measure pulses that uses polarization gating FROG for measuring two unknown pulses. In the last part, we briefly discuss the designing of a high energy chirped pulse amplification system.
-
Polarimetric methods for the image enhancement in biological applications
… anomenades Portes de Polarització (de l’anglès “Polarization Gating”) i tècniques basades en la matriu de Mueller. En aquesta tesi, s’investiga la relació que hi ha entre aquests dos grups de tècniques polarimètriques i proposem un nou mètode polarimètric més general que permet analitzar …
-
Prospects for single shot diffraction imaging with laser-plasma driven high harmonic sources
… techniques. <br/><br/>A novel combination of polarization gating techniques and a two-colour laser pulse is presented as a tool to isolate and enhance single attosecond scale pulses. Numerical results show that by using solid target HHG, a table top system is capable of generating very short …
-
MAPPING OPTICAL PROPERTIES OF THE ESOPHAGUS USING SPATIAL FREQUENCY DOMAIN IMAGING
… improved tissue identification. Additionally, polarization gating and high spatial-frequency illumination techniques were implemented to quantify and visualize phase function information for tissue microstructure. During optical property extraction, SFDI implements corrections on reflectance …
-
OPTICAL COHERENCE TOMOGRAPHY OPHTHALMIC SURGICAL GUIDANCE
… in situ through the combination of confocal gating, coherence gating, and polarization gating. Because it is noninvasive, OCT has been used in multiple clinical applications such as tissue pathology assessment and interventional procedure guidance. Moreover, OCT can perform functional …
-
Generation and applications of intense isolated attosecond pulses
… a new technique, which is called Interferometric Polarization Gating (IPG) is proposed, developed and implemented, based on the second approach. By appling this technique, the appropriate control of the high harmonic generation process is feasible leading to the generation of intense coherent XUV …
-
Visualization and control of the electron quantum paths in high field laser-atom interactions
… by utilizing a compact collinear many cycle-polarization gating (CMC-PG) device. The CMC-PG device formulates the many-cycle driving pulse in such a way that the EUV emission is canceled anywhere else but in a small energetic interval of the proper small duration; the so-called “gate”. The …
-
Generation and Characterization of Isolated Attosecond Pulse in the Soft X-ray Regime
… exceeding 300 eV are achieved by applying the polarization gating technique at 1.7 micron. The intrinsic positive chirp of the attosecond pulses is measured by the attosecond streak camera and retrieved with our PROOF technique. Sn metal filters with negative dispersion were chosen to …
-
High-order harmonic generation with few-cycle pulses for ultrafast electron spectroscopy
… through precise control of the time-dependent polarization of the driving laser field. Subcycle polarization gating, where linear polarization is confined near the peak of the pulse envelope, strongly reduced the attosecond pulse duration. This was experimentally evidenced by the presence of …
-
Generation and characterization of sub-70 isolated attosecond pulses
… research groups. An alternative method termed as polarization gating generated single attosecond pulses with 5 fs driving pulses, which is still difficult to achieve experimentally. Most recently, a new technique termed as Double Optical Gating (DOG) was developed in our group to allow the …
-
Strong-field physics in tailored light
… pulses generated via HHG in neon and driven by polarization-tailored few-cycle MIR pulses, commonly referred to as polarization gating. Accurate estimation of the attosecond soft-X-ray pulses in such experiments remains challenging given their higher photon energies and broad spectral bandwidth. …
-
Elliptically polarized light for depth resolved diffuse reflectance imaging in biological tissues
L’imagerie de filtrage en polarisation est une technique populaire largement utilisée en optique pour le biomédical pour le sondage des tissus superficiels, pour le sondage de volumes plus profonds, mais aussi pour l’examen sélectif de volumes sub-surfaciques. Du fait de l’effet de ’mémoire de …