Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 129 for “"Pollutant concentration"”.

  1. Fabrication of integrated optic sensor to monitor pollutant concentration in effluents

    … fabricate an integrated optic sensor to monitor pollutant concentration in effluents. Optic fiber has to be coupled to the waveguide in order to send light through the waveguide. In order to facilitate the easy coupling of the fiber to the waveguide, V-grooves were formed in the silicon …

    njit Repository record for Fabrication of integrated optic sensor to monitor pollutant concentration in effluents (opens in a new tab)

  2. Multifunctional experimental assessment in a newly established Mediterranean restored marsh : marsh elevation, carbon accumulation and pollutant concentration reduction

    … with flooding risk, carbon (C) sequestration and pollutant removal services. A need for more knowledge is required to optimize factors controlling these ecosystem services seeking to work as natural defence against flooding risk, sequestering C, as well as natural filters of agricultural runoff. …

    ecu Repository record for Multifunctional experimental assessment in a newly established Mediterranean restored marsh : marsh elevation, carbon accumulation and pollutant concentration reduction (opens in a new tab)

  3. DEVELOPMENT OF A FUZZY MODEL FOR ASSESSING INDOOR AIR QUALITY

    … air comprises of objective measurement of indoor pollutant concentration levels and the environment perception survey responses of the building occupants. Notably, acceptable indoor air quality (IAQ) refers to air in which there are no known contaminants at harmful concentrations as determined by …

    nus Repository record for DEVELOPMENT OF A FUZZY MODEL FOR ASSESSING INDOOR AIR QUALITY (opens in a new tab) Download file for DEVELOPMENT OF A FUZZY MODEL FOR ASSESSING INDOOR AIR QUALITY (opens in a new tab)

  4. The study of pollutant removal from urban stormwater using a constructed wetland

    … for its ability to treat urban stormwater pollutants. Monitoring was conducted during two moderate storm events and two non-storm events. Pollutant concentration was measured at 24 hour intervals over periods of approximately one week.

    vu-aus Download PDF for The study of pollutant removal from urban stormwater using a constructed wetland (opens in a new tab)

  5. Bayesian Pollution Source Apportionment Incorporating Multiple Simultaneous Measurements

    … pollution sources in a region based on daily pollutant concentration measurements from multiple measurement stations over a period of time. In an extension of existing work, we will estimate common source profiles but distinct contribution levels based on measurements from each station. In …

    byu Repository record for Bayesian Pollution Source Apportionment Incorporating Multiple Simultaneous Measurements (opens in a new tab) Download PDF for Bayesian Pollution Source Apportionment Incorporating Multiple Simultaneous Measurements (opens in a new tab)

  6. Development of roadway link screening criteria for microscale carbon monoxide and particulate matter conformity analyses through application of classification tree model

    … tool, is used to predict downwind CO and PM concentrations for various receptors to generate a learning dataset for development of screening rules. This research has developed statistical screening criteria based on Classification and Regression Tree modeling that can be used to eliminate …

    gatech Repository record for Development of roadway link screening criteria for microscale carbon monoxide and particulate matter conformity analyses through application of classification tree model (opens in a new tab)

  7. A comparison study of atmospheric stability indicators

    … certain hours of the day. This suggests that pollutant concentration predictions as a result of air quality modeling during these periods will vary depending on the stability indicator used.</p>

    ut-knoxville Repository record for A comparison study of atmospheric stability indicators (opens in a new tab)

  8. Transient analysis of the dispersion of vehicle pollution within a highway tunnel

    … stall, slowdown, and/or normal speed resumption, pollutant concentration build-up, and propagation through the tunnel is computed, and parametric studies are reported. <p> The model assumes one-dimensional, imcompressible airflow in the tunnel. The governing equation of transient induced airflow …

    ut-knoxville Repository record for Transient analysis of the dispersion of vehicle pollution within a highway tunnel (opens in a new tab)

  9. Degradation of dichloromethane, trichloromethane & carbon tetrachloride in a photoreactor

    … to study the degradation of EPA priority pollutants. This newly designed system was used to study the kinetics of degradation of dichloromethane, trichloromethane and carbon tetrachloride under O<sub>2</sub>/UV, O<sub>3</sub>/O<sub>2</sub>/UV and H<sub>2</sub>O<sub>2</sub>/UV schemes. …

    njit Repository record for Degradation of dichloromethane, trichloromethane & carbon tetrachloride in a photoreactor (opens in a new tab)

  10. Estimation of Air Quality Criterion-based Building Setback Distance From Urban Roads and Freeway Using Microscopic Simulation of Traffic, Emissions, and Pollution Dispersion

    … and other sources that exceed well-defined concentrations affect human health. To protect people, especially vulnerable members of population, ambient air quality standards and guidelines should be met. According to projections, the internal combustion engine vehicles are likely to maintain …

    carleton Repository record for Estimation of Air Quality Criterion-based Building Setback Distance From Urban Roads and Freeway Using Microscopic Simulation of Traffic, Emissions, and Pollution Dispersion (opens in a new tab)

  11. Modelling Stormwater Pollutants in Hamilton, Canada

    … of the various processes involved in pollutant buildup, washoff and routing and insufficient, and faulty data collection, urban runoff models depict runoff quality poorly. This research therefore attempts to introduce new concepts and algorithms, based on the physical processes …

    mcmaster Repository record for Modelling Stormwater Pollutants in Hamilton, Canada (opens in a new tab)

  12. Simulation and design of diversion and detention system for urban stormwater management

    … flush of storm runoff to a detention basin for pollutant removal is an efficient way to control nonpoint source pollutant in urban areas. This can be achieved by a diversion box and detention basin system. To numerically simulate the response of the system to a design rainfall event and the …

    vt Repository record for Simulation and design of diversion and detention system for urban stormwater management (opens in a new tab)

  13. EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE 1AQ

    … how the daily purging operation affected pollutant concentration at the low, middle and high storeys of the office building. Pollutants investigated included formaldehyde, carbon dioxide, carbon monoxide and volatile organic compounds. Secondly, Air Purging tests using sulphur hexafluoride …

    nus Repository record for EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE 1AQ (opens in a new tab) Download file for EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE 1AQ (opens in a new tab)

  14. EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE IAQ

    … how the daily purging operation affected pollutant concentration at the low, middle and high storeys of the office building. Pollutants investigated included formaldehyde, carbon dioxide, carbon monoxide and volatile organic compounds. Secondly, Air Purging tests using sulphur hexafluoride …

    nus Repository record for EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE IAQ (opens in a new tab) Download file for EFFECTIVENESS IN USE OF EXISTING OFFICE AIR CONDITIONING SYSTEM WITH AIR PURGING SYSTEM TO REPLACE INDOOR AIR TO ENHANCE IAQ (opens in a new tab)

  15. Emissions Studies for a Natural Gas-Fired Internal Combustion Engine

    … raw exhaust-gas data for the more important pollutants were taken and analyzed in both systems under different loads and intake manifold pressures. In addition, to obtain a minimum-emissions calibration of the engine, the effects of spark advance on pollutant concentration were studied. The …

    odu Repository record for Emissions Studies for a Natural Gas-Fired Internal Combustion Engine (opens in a new tab)

  16. Heterogeneous photocatalysis: Design and experimental characterization of a new photocatalytic reactor for wastewater treatment

    … on an analysis of rotational speed and initial pollutant concentration, the reaction was found to be limited by the kinetics at 20 ppm and 40 ppm, but limited by phenol transfer to the reaction sites at 5 ppm. Finally, Langmuir-Hinshelwood kinetics was applicable with an average phenol …

    ottawa-retro Repository record for Heterogeneous photocatalysis: Design and experimental characterization of a new photocatalytic reactor for wastewater treatment (opens in a new tab)

  17. Diffusion-deposition of particles from a continuous line source into a disturbed atmospheric boundary layer

    … the numerical method. For the estimation of the pollutant concentration and deposition the gradient-transfer model is applied. The Crank-Nicolson scheme which is modified to be the Gauss-Seidel with Successive-Over-Relaxation method is used. Comparisons and analyses are performed based on these …

    iastate Repository record for Diffusion-deposition of particles from a continuous line source into a disturbed atmospheric boundary layer (opens in a new tab)

Page 1 of 7