Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Polymer Gel Dosimeters"”.

  1. Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide

    … dose response and ease of manufacture of polymer gel dosimeters that use N-isopropyl acrylamide (NIPAM) as the monomer. An alternative carageenan gelling agent was tested in place of gelatin. Although the carageenan did reduce the gelling time for the dosimeter solution, the dose response …

    queens Repository record for Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide (opens in a new tab)

  2. Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters

    A mathematical model for polymer gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results …

    queens Repository record for Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters (opens in a new tab)

  3. Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner

    … of an advanced dosimeter --- the polyacrylamide, gelatin, and tetrakis (hydroxymethyl) phosphonium chloride (PAGAT) dosimeter --- using a prototype fan-beam optical computed tomography (CT) scanner. A number of developments sought to improve the performance of the optical CT device. A new …

    uvic Repository record for Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner (opens in a new tab)

  4. Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams

    This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and …

    uthsc Repository record for Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams (opens in a new tab)

  5. Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography

    Polymer gel dosimeters are a three dimensional (3D) dosimetry system that may be conveniently applied for verifying highly conformal radiation therapies where standard dosimetry techniques are insufficient. Polymer gel dosimetry with optical computed tomography (OptCT) can be used to measure …

    queens Repository record for Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography (opens in a new tab)

  6. Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry

    … techniques. It is hypothesized that deformable polymer gels can provide volumetric dosimetric information for the assessment of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos. This hypothesis will be investigated by (1) using stationary polymer gel dosimeters (PGDs) to …

    ubc Repository record for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab) Download PDF for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab)

  7. Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry

    … of MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) polymer gel dosimeters have been characterized. The variations of speed of sound, ultrasonic attenuation coefficient and density of MAGIC gel with radiation dose and temperature have been quantified. This extends work …

    soton Download PDF for Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry (opens in a new tab)

  8. Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry

    Polymer gel dosimetry, in conjunction with x-ray computed tomography (x-ray CT) imaging, is a three-dimensional dosimetric tool that shows promise in the verification of complex radiation therapy treatments. Previous studies have shown that x-ray CT imaging of gel dosimeters is robust, easy-to-use, …

    uvic Repository record for Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry (opens in a new tab)

  9. Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος

    … dosimetric results by the utilization of MRI polymer gel dosimetry methodologies and (b) to optimize the dosimetric radiotherapy results in conformal radiotherapy by the utilization of Magnetic Resonance Imaging in special phantoms.Nowadays, polymer gel dosimeters have been proven a valuable …

    greece Repository record for Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος (opens in a new tab)

  10. Modeling and Development of Three-Dimensional Gel Dosimeters

    … to simulate the response of polyacrylamide gel (PAG) dosimeters to a single spherical radioactive brachytherapy seed. Simulations were conducted for a high dose-rate (HDR) seed using 192Ir and a low dose-rate (LDR) seed using 125I. The model is able to predict the amount of polymer formed, …

    queens Repository record for Modeling and Development of Three-Dimensional Gel Dosimeters (opens in a new tab)