Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Polymer Gel Dosimetry"”
-
Applications of x-ray computed tomography polymer gel dosimetry
… these advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This dissertation investigates the …
-
Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy
… at best in quasi-3D. The implementation of 3D dosimetry into clinical dosimetry requires attention to safety, accuracy, and rigorous validation prior to any routine patient treatment. Polymer gel detectors have previously been shown to be a useful tool to capture complex 3D dose distributions …
-
X-ray computed tomography for performing polymer gel dosimetry : a feasibility study
… resolution three dimensional (3D) dosimeter. Polymer gels are novel, inherently 3D, tissue equivalent radiation dosimeters. Traditionally, dose distributions recorded in polymer gel are read out using magnetic resonance imaging (MRI). Presented here is a feasibility study on a new 3D dosimetry …
-
3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry
Polymer gel dosimetry has been used since the 1990s, and several studies have shown that this detector system can be used for verification of static absorbed dose distributions in three dimensions (3D). Its unique properties, such as high resolution, normal tissue equivalence and independency of …
-
Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry
… techniques. It is hypothesized that deformable polymer gels can provide volumetric dosimetric information for the assessment of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos. This hypothesis will be investigated by (1) using stationary polymer gel dosimeters (PGDs) to …
-
An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification
X-ray computed tomography (CT) polymer gel dosimetry (PGD) is an attractive tool for three-dimensional (3D) radiation therapy (RT) treatment verification due to the availability of CT scanners in RT clinics. Nevertheless, wide-spread use of the technique has been hindered by low signal-to-noise CT …
-
Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification
… this clinical challenge that utilizes a 3D NIPAM polymer gel dosimetry system with CBCT readout to verify the dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) and spatially fractionated radiotherapy (SFRT) technique. Three main objectives of this work are 1) to evaluate the …
-
Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography
Polymer gel dosimeters are a three dimensional (3D) dosimetry system that may be conveniently applied for verifying highly conformal radiation therapies where standard dosimetry techniques are insufficient. Polymer gel dosimetry with optical computed tomography (OptCT) can be used to measure …
-
Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος
… dosimetric results by the utilization of MRI polymer gel dosimetry methodologies and (b) to optimize the dosimetric radiotherapy results in conformal radiotherapy by the utilization of Magnetic Resonance Imaging in special phantoms.Nowadays, polymer gel dosimeters have been proven a valuable …
-
Evaluation of yttrium-90 positron emission tomography dosimetry
… tumors. Radioembolization dose planning and dosimetry are based on crude, inaccurate assumptions due to the lack of knowledge of patient specific 90Y microsphere distribution. In recent years, the very small 3.1867e-5 internal pair production decay branch of 90Y has been shown to allow for …
-
Three-dimensional dosimetry around small distributed high-Z materials
… IGRT or targeted therapies. Previous, interface dosimetry studies focused high-Z materials irradiated by low energy beams where the dose enhancement is large. In the majority of the cases, they used one or two dimensional detectors. Therapeutic beams, however, are mostly 6 MV and higher with …
-
3D ultrasound-based patient positioning for radiotherapy
… system to be simulated. This method uses polymer gel dosimetry to record the dose delivered to a phantom, allowing this to be compared to the intended dose plan, thereby closing the loop on the entire treatment process. The mean target localisation accuracy of the proposed system was 2.5mm …
-
Ανάπτυξη μεθοδολογιών και εργαλείων για την αξιολόγηση, βελτιστοποίηση και διόρθωση των γεωμετρικών παραμορφώσεων και του σήματος εικόνων απεικόνισης μαγνητικού συντονισμού που χρησιμοποιούνται σε εφαρμογές στερεοτακτικής ακτινοχειρουργικής - ακτινοθεραπείας
… are a major obstacle to the adoption of 3D dosimetry applications in clinical practice, such as 3D polymer gel dosimetry. Distortion correction can lead to more precise targeting of possible lesions and optimization of 3D dosimetry to obtain more complete dose information with the highest …
-
Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification
… tomography (OptCT) scanner for three-dimensional polymer gel dosimetry of complex radiotherapy protocols has been developed. This study documents the design. construction and characterization of the system, as well as preliminary reconstructed optical attenuation images and dosimetric verification …
-
Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry
Polymer gel dosimetry, in conjunction with x-ray computed tomography (x-ray CT) imaging, is a three-dimensional dosimetric tool that shows promise in the verification of complex radiation therapy treatments. Previous studies have shown that x-ray CT imaging of gel dosimeters is robust, easy-to-use, …
-
Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters
A mathematical model for polymer gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results …
-
Investigations in x-ray computed tomography polyacrylamide gel dosimetry
Polyacrylamide gels (PAGs) are radiosensitive materials currently under development for use as three dimensional (3D) dosimeters in radiation therapy. Dose information is recorded in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method …
-
Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας
… in the clinical outcome. However, small field dosimetry in SRS involves a high level of uncertainties. Moreover, treatment’s total spatial errors stem from any link of the treatment chain and should be thoroughly evaluated. Another important factor is the radiobiological effectiveness of the …