Three-dimensional dose reconstruction using non- transmission portal dosimetry and Monte Carlo calculations
Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) offer convenient high-resolution and fast digital image acquisition, making the a-Si EPID advantageous for portal dosimetry. In this research project, a Varian aS1000 EPID was dosimetrically evaluated for portal dosimetry …
-
On the Development of Computational Methods to Help in Performing Medical Physics Tasks Leveragin the Portal Dosimetry Application
… planning system of Varian Medical Systems. The Portal Dosimetry Application of Eclipse is used to collect the image pixels. The pixels are then displayed in a Windows Presentation Foundation using Microsoft Visual Studio and C#. The purpose of the Gamma Index pass rates software is to benchmark …
-
A Novel Algorithm for the Reconstruction of an Entrance Beam Fluence from Treatment Exit Patient Portal Dosimetry Images
The problem of determining the in vivo dosimetry for patients undergoing radiation treatment has been an area of interest since the development of the field. Most methods which have found clinical acceptance work by use of a proxy dosimeter, e.g.: glass rods, using radiophotoluminescence; …
-
Creating A Dynamic, Multi-Purpose Correction for Multiple Geometries and Field Sizes to Account for Off-Axis and Asymmetric Backscatter With Varian Portal Dosimetry
… accelerators (linac) is to use an electronic portal imaging device (EPID). Amorphous silicon (aSi) Electronic Portal Imaging Devices (EPIDs) are attached to the linac and can provide real-time feedback with spatial resolution on the order of sub-millimeter pixel size making them very favorable …
-
Caracterización y comisionamiento de un sistema de imágenes portales para verificación pretratamiento en radioterapia de intensidad modulada
… de un dispositivo electrónico de imágenes portales (EPID, por sus siglas en inglés) PortalVision aS500, instalado en el acelerador lineal iX 4034 del Centro de Control de Cáncer en Bogotá, Colombia, fueron estudiadas en el presente trabajo, así como el sistema Portal Dosimetry fue …
-
Characterization of Physical and Dosimetric Aspects of SRS HyperArc Treatment Technique
… an ion chamber and Gafchromic EBT-XD film and portal dosimetry. The conclusions from these investigations were that patient rotation will result in a loss of target coverage, which is emphasized for smaller targets and isocenter placement farther away from the lesion. The use of a six degree of …
-
Comparación de las verificaciones con octavius II + 729 y EPID en planeaciones de cabeza y cuello y próstata, realizadas con técnica VMAT
… VeriSoft, y el detector EPID con su programa Portal Dosimetry, según su uso en el ámbito clínico de la radioterapia, de igual manera se compararon los resultados obtenidos con ambos detectores en el control de calidad de 10 planeaciones de Próstata y 10 de Cabeza – Cuello. Se realizaron …
-
Implementación de tratamientos de radiocirugía en un acelerador lineal clínico de un hospital público de mediana y alta complejidad en el Valle del Cauca, 2021
… TG 119 usando los fantoma Octavius 4D, Ruby y el Portal Dosimetry. Para la técnica VMAT y las evaluaciones del índice gamma usando el Octavius 4D se encontraron valores del límite de confianza de 4.5, 4.7, 4.06, 5.30 y 4.5 para los haces de energía 6, 6 FFF, 10, 10 FFF y 16 MV, respectivamente, …
-
Enhanced Megavoltage Imaging for Radiotherapy by Light-Field Imaging of Scintillators
… beam's eye view of patient anatomy,allowing for portal dosimetry and real-time tumor position tracking without additional dose. However, current electronic portal imaging devices (EPIDs) suffer poor contrast-to-noise ratios because of their limited (1-2%) detective quantum efficiency (DQE). …
-
Enhanced Megavoltage Imaging for Radiotherapy by Light-Field Imaging of Scintillators
… beam's eye view of patient anatomy,allowing for portal dosimetry and real-time tumor position tracking without additional dose. However, current electronic portal imaging devices (EPIDs) suffer poor contrast-to-noise ratios because of their limited (1-2%) detective quantum efficiency (DQE). …
-
Επιβεβαίωση πλάνου ακτινοθεραπείας Ca προστάτη , με τεχνική VMAT. Σύγκριση τεσσάρων μεθόδων
… μεθόδους. Οι δυο μέθοδοι, EPIQA και Varian Portal Dosimetry, χρησιμοποιούν εικόνες που λαμβάνονται με τη συσκευή EPID που διαθέτει ο γραμμικός επιταχυντής, ενώ οι άλλες δύο μέθοδοι χρησιμοποιούν ανεξάρτητα μετρητικά συστήματα, το MapCΗΕCK 2 SunNuclear και Film EBT3. Αξίζει να σημειωθεί ότι …
-
A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices
… from the convenience of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these …
-
Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging
In vivo dosimetry (IVD) in radiotherapy refers to direct measurement of dose deposited in the patient during treatment. IVD can be of great use in early detection of harmful errors, for assessment of patient setup and anatomy changes, and to guide adaptive radiotherapy. Routine IVD is hindered by …
-
Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device
… verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate …