  1. Optimization Of Portal Imaging Systems

    Many portal imaging devices have been developed to verify the geometric accuracy of radiation therapy treatments. Portal imaging devices are used to take images of the patient during radiation therapy treatments. These images are used to detect patient positioning errors which may jeopardize the …

    uwo Repository record for Optimization Of Portal Imaging Systems (opens in a new tab)

  2. 2D transit dosimetry using electronic portal imaging device

    The amorphous silicon electronic portal imaging device (a-Si EPID) was originally designed for positional verification in radiotherapy. Several feature of the a-Si EPID, such as the high-resolution detector array and ease of operation, have made this imaging device an attractive tool for dose …

    glasgow Repository record for 2D transit dosimetry using electronic portal imaging device (opens in a new tab)

  3. 3-D automatic anatomy-based image registration in portal imaging

    … dimensional, automatic, anatomy-based system for portal verification has been developed based on an FFT implementation of Pearson's correlation coefficient (PCC). The PCC requires no anatomy or point-pair identification, is robust when encountering changes in scaling and shifts in image amplitudes …

    mcgill Repository record for 3-D automatic anatomy-based image registration in portal imaging (opens in a new tab)

  4. Portal imaging with a direct-detection active matrix flat panel imager

    … published DQE of an indirect detection AMFPI for portal imaging. The direct detector has a lower DQE at zero frequency, but there is a cross-over at approximately 0.3 cycles/mm after which it has a higher DQE. A theoretical expression for the DQE of medical imaging detectors with non-elementary …

    mcgill Repository record for Portal imaging with a direct-detection active matrix flat panel imager (opens in a new tab)

  5. Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera

    … was to design a high performance digital portal imaging system, using a transparent x-ray scintillator coupled to a cooled CCD camera. Theoretical analysis using Monte Carlo simulation was performed to calculate the QDE, SNR and DQE of the system. A prototype electronic portal imaging …

    tenn-hsc Repository record for Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera (opens in a new tab)

  6. The application of electronic portal imaging devices to radiotherapy quality assurance / Guilin Liu.

    … demonstrate the potential for using Electronic Portal Imaging Devices for quality assurance tests with the aim of improving the accuracy and efficiency of radiotherapy QA.

    adelaide Repository record for The application of electronic portal imaging devices to radiotherapy quality assurance / Guilin Liu. (opens in a new tab)

  7. Real Time Prostate Motion Tracking Using the Portal Imaging Device in Radiation Therapy

    Intrafractional motion management is the key step in image-guided radiation therapy. Prostate location can change vastly during treatment. This work is to provide a way to implement and facilitate real-time MV tumor surrogate tracking of the fiducial marker implanted for prostate cancer treatment. …

    buffalo Repository record for Real Time Prostate Motion Tracking Using the Portal Imaging Device in Radiation Therapy (opens in a new tab)

  8. Effect of Slit Scan Imaging Techniques on Image Quality in Radiotherapy Electronic Portal Imaging

    … in improving image quality of teletherapy portal imaging for various imaging geometries. The primary result of this study was the validation that slit scan digital radiography improves the quality of a portal image by scatter reduction resulting from the patient and machine. This method …

    ohiolink Repository record for Effect of Slit Scan Imaging Techniques on Image Quality in Radiotherapy Electronic Portal Imaging (opens in a new tab)

  9. Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling

    As the use of electronic imaging devices (EPIDs) increases, the emphasis which was initially on geometric verification, is shifting to portal exit dosimetry. In this latter concept, a portal dose image obtained during treatment with an EPID is compared with that calculated during treatment …

    manitoba Repository record for Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling (opens in a new tab)

  10. Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry

    … directing one or more megavoltage xray treatment portals at the diseased area from different directions. In theory, this principle maximizes the dose to the target site while minimizing the dose to surrounding healthy tissue. The efficacy of a course of radiation therapy may however be compromised …

    ubc Repository record for Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry (opens in a new tab)

  11. Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams

    … to the success of radiation therapy. The use of portal imaging in radiotherapy for verification of field size, shape, orientation and patient setup is of vital importance in delivering successful radiation treatment. One of the modalities used in improving tumor localization and geometric …

    ubc Repository record for Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams (opens in a new tab)

  12. A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices

    … from the convenience of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these …

    mcmaster Repository record for A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices (opens in a new tab)

  13. Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging

    … describe a novel method of using the electronic portal imaging device (EPID) for IVD. Images are measured through phantoms/patients making use of treatment beams. From these, 2D dose maps at isocentre depth are calculated from signal-to-dose correlation ratios. Convolution by optimized …

    calgary Repository record for Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging (opens in a new tab)

  14. Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    … The digital image format makes electronic portal imaging devices (EPIDs) good candidates for in vivo dosimetry. Currently there is no commercial transit dosimetry module, which could facilitate routine in vivo dosimetry with the EPID. Some centres are developing their in-house packages, and …

    glasgow Repository record for Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device (opens in a new tab)

  15. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    … verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate …

    manitoba Repository record for Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device (opens in a new tab)

  16. Design & Delivery of Automated Winston-Lutz Test for Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device

    … off-isocenter, and then were exported as Digital Imaging and Communication in Medicine format (DICOM) file to Python. Out of these DICOM treatment planning files, Python would generate an eXtensible Markup Language (XML) file of the automated WL test with all the collimating leaves positions …

    unlv Repository record for Design & Delivery of Automated Winston-Lutz Test for Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device (opens in a new tab)