Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Portal monitors"”.
-
Optimization of Scintillator based Radiation Portal Monitors
… to replace the current He- 3 based Radiation Portal Monitors (RPM) which are employed to detect special nuclear material that may be entering the United States illicitly. Replacement technologies must fulfill the following criteria established by the Department of Homeland Security (DHS): 1) a …
-
Important factors in predicting detection probabilities for radiation portal monitors
… of detection probabilities for radiation portal monitors (RPMs). The application of innovative detection technology to improve operational sensitivity of RPMs has received increasing attention in recent decades. In particular, two alarm algorithms, gross count and energy windowing, have …
-
Testing the Benefits of Using Silicon Photomultipliers on Organic Scintillator Portal Monitors
… volumes in the cubic millimeter range, but large portal monitors are often used at ports of entry and traffic control points to monitor radiation. This research examined the efficacy of SiPMs placed on larger plastic scintillators with volumes orders of magnitude larger than previous tests have …
-
Evaluation of internal contamination levels after a radiological dispersal device using portal monitors
… is necessary. Thermo Scientific's TPM-903B Portal Monitor was investigated to determine if it is a suitable first cut screening tool for internal contamination assessment of victims. A portal monitor was chosen for this study because they are readily accessible, transportable, easy to …
-
A Strategic Analysis of Stationary Radiation Portal Monitors and Mobile Detection Systems in Border Monitoring
Radiation Portal Monitors (RPM) are our primary border defense against nuclear smuggling, but are they still the best way to spend limited funds? The purpose of this research is to strategically compare RPM defense at the border with state-side mobile detectors. The challenge of an adequately …
-
Leveraging the Spatial Response of Radiation Portal Monitors: Spatial Characterisation of Radioactive Materials Concealed within Shipping Containers
… detection infrastructure relies on radiation portal monitors (RPMs) containing γ-radiation detectors to identify the presence of radioactive and nuclear materials, based principally on count-rate anomalies or changes in the energy distribution of γ-radiation measurements. The primary aim of …
-
Monte Carlo determination of detection efficiency for portal monitoring
… of crowds, and at high risk locations, portal monitors are used to detect the presence of ionizing radiation and ensure radiological/nuclear materials do not fall out of regulatory control or are utilized with malicious intent. This work uses computer models to determine the probability …
-
A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination.
The goal of this research was to investigate if portal monitors could measure internally deposited radioisotopes over a short count time (1 second) with a detection limit sufficient to measure 1/10 of an annual limit on intake (ALI) of specific radionuclides. The goal was to determine if portal …
-
Determining the Impact of Concrete Roadways on Gamma Ray Background Readings for Radiation Portal Monitoring Systems
… the threat of nuclear trafficking, radiation portal monitors (RPMs) are deployed around the world to intercept illicit material while in transit by passively detecting gamma and neutron radiation. Portal monitors in some locations have reported abnormally high gamma background count rates. The …
-
DESIGN OF A NEUTRON DETECTOR CAPABLE OF REPLACING HE-3 DETECTORS UTILIZING THIN POLYMERIC FILMS
… Monte Carlo transport code (MCNPX) as radiation portal monitors. It is determined that thin polymeric films would have a high enough interaction rate to satisfy the DHS-DNDO requirements while still maintaining the necessary gamma discrimination.</p>
-
Characterization of Lithium-6 as a Commercial Helium-3 Alternative for Nuclear Safeguards and Security
… detector from Aspect used in their portal monitors.</p> <p>There are three basic requirements for neutron detectors used in nuclear safeguards and security: 1) high absolute detection efficiency, 2) maintaining neutron detection efficiency when simultaneously exposed to a high gamma …
-
Θεωρητικός και πειραματικός προσδιορισμός πεδίων ραδιενέργειας με εφαρμογή στην βιομηχανία ανακύκλωσης παλαιών μετάλλων
… metal is pragmatic. Subsequently the radiation portal monitors that scan scrap loads at the factory entrance were modeled. The model was validated through comparison of both response and spectral measurements with analogous simulations. This model was tested for a load portal monitor geometry …
-
Comparison of radiation damage effects in organic and silicon photodetectors
… for use in nuclear material verification and in portal monitors requires rugged systems capable of withstanding high fluences of mixed-field radiation. As the use of solid-state photodetectors (for use in scintillation light detection) has grown in recent years, their ability to maintain …
-
Determination and Mitigation of Precipitation Effects on Portal Monitor Gamma Background Levels
… background gamma radiation levels at radiation portal monitors (RPM) deployed at various ports worldwide, and to devise a mechanism by which the effects of these precipitation-induced background fluctuations could be mitigated. The task of detecting special nuclear materials (SNM) by passive …
-
Analysing the impact of detector properties on pulse shape discrimination in plastic scintillation detectors using Monte Carlo simulations
… for large-area applications, such as radiation portal monitors (RPMs) used in homeland security. To address this, a systematic study was conducted using the Monte Carlo simulation toolkit Geant4. This research evaluates how variations in scintillator geometry and length, optical surface …
-
Development of an Alternative to the Helium-3 Based Active Well Coincidence Counter with Boron Coated Straws
… a neutron detector has been proven in radiation portal monitors, vehicle mounted modular detectors, and handheld detectors, but has yet to be assessed in an AWCC with its original footprint. Analysis of the original AWCC with^ 3He and alternatives with ^10B-lined tubes and BCS was done in MCNPX. …
-
Developing a Methodology for Characterizing the Effects of Building Materials’ Natural Radiation Background on a Radiation Portal Monitoring System
… the US government has installed radiation portal monitors (RPMs) around the globe. Building materials surrounding an RPM can greatly effect the detector’s background radiation levels due to Naturally Occurring Radioactive Material (NORM). In some cases this effect is so great that the …
-
Simulation of radiological background data for benchmarking statistical algorithms to enhance current radiological detection capabilities
… obtained by measurement systems, such as portal monitors, which collect data on a continuous basis. The hypothesis is that patterns can be identified in sequences of repeated count rate measurements and used in conjunction with classical statistics to identify and locate a source. By …
-
Mutable Detector Array Software for the Detection of Gamma Emissions in Classrooms and the Field
… is a key component. This can take the form of portal monitors attached to a fixed location or a movable array, attached to a vehicle or person, which searches for abnormalities in the radiation background. The main goal of this project was to create software that would allow the digiBASE-E to …
-
PVT/PMT System Feedback Design and Feasibility Study
Radiation portal monitors (RPMs) are employed worldwide at border crossings and other entry points as a method to detect the illegal transportation of radioactive material. Scintillating detectors composed of polyvinyl toluene (PVT) plastic are installed within the RPMs for vehicle and cargo …
Page 1 of 2