Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 43 for “"Position Reconstruction"”
-
FPGA-Accelerated Inference for Electron Microscopy: Design and Optimization of Quantized CNNs for Electron-Impact Position Reconstruction
… neighboring pixels. The resulting charge-deposition pattern does not directly indicate the electron’s original entry position, limiting the effective spatial resolution of the detector. This thesis applies a model-hardware co-design approach to optimize and deploy convolutional neural …
-
Transverse Position Reconstruction in a Liquid Argon Time Projection Chamber using Principal Component Analysis and Multi-Dimensional Fitting
… however, is the determination of an event’s position along the other two spatial dimensions, that is, its transverse or "xy" position. Some liquid noble element TPCs have achieved remarkably accurate event position reconstructions, typically using the relative amounts of S2 light collected by …
-
ATLAS Electromagnetic Calorimeter performance measurements, search for the Higgs boson in the H→Zγ channel and detector development for position reconstruction of noble liquid scintillation
… of Thick GEM structures intended for gamma-ray position reconstruction in liquid argon. The detector has a MgF2 window, transparent to VUV light, and a CsI photocathode deposited on the first THGEM. A 10 cm2 area is instrumented with four readout channels. A gain of 8·10E5 per photoelectron and …
-
Machine Learning for XENONnT and Bayesian Inference in Astroparticle Physics
… The focus is on data processing, signal reconstruction, and the application of machine learning techniques to improve event localization and statistical inference. A multilayer perceptron and a domain-informed neural network were developed and trained for S2 position reconstruction, …
-
K2K near detector laserball calibration : manipulator motivation, design and results
… Kilo Ton (1KT) detector found problems with the position reconstruction a manipulation system was built. The goal of this manipulation system was to allow exploration of the entire 1KT volume with a calibration source. The design required the manipulation system to place the calibration source to …
-
Event Reconstruction in SNO+ with Graph Neural Networks
… neutrinoless double beta decay in Te-130. The reconstruction of the position of particle interaction events in the detector volume is central to the SNO+ data analysis pipeline. This thesis presents a new method of position reconstruction using the machine learning method of Graph Neural …
-
Design and Analysis for the DarkSide-10 Two-Phase Argon Time Projection Chamber
… discrimination and gives event location using position reconstruction. Based on using COMSOL multiphysics software, the TPC electric fields were simulated. For DarkSide-10 the maximum radial displacement a drifting electron would undergo was found to be 0.2 mm and 1 mm for DarkSide-50. Using …
-
Optical Beam Loss Monitors: Instrumentation Development and Advanced Signal Analysis
… at CLEAR was used to investigate multiple loss position reconstruction algorithms, resulting in an optimal accuracy of 1 m and the system being utilised operationally. Furthermore, both with Monte-Carlo simulations and experimental measurements, it was shown that the beam energy, position and …
-
Characterization of the Xenon-10 Dark Matter Detector with regard to electric field and light response
… scintillation light were instrumental in position reconstruction in the gas phase of the detector and in the identification of events occurring inside the problem regions found in the electrostatic simulations. Data comparison with Activated Xenon (131Xe) with its gamma ray feature at 164 …
-
Spatial Resolution Studies for the LHCb VELO Upgrade
… analogue (Centre of Gravity) and binary position reconstruction algorithms were performed on TimePix3 data and the spatial resolutions compared. Binary resolution was found to be better than analogue resolution indepen- dent of the applied bias voltage, both before and after irradiation. …
-
Position resolution of the ATLAS electromagnetic endcap calorimeter
The position reconstruction performance of the Electromagnetic Endcap Calorimeter (EMEC) is assessed in terms of its response to electrons. The electromagnetic and hadronic endcap calorimeter modules of the ATLAS detector are exposed to beams of electrons, pions, and muons in the energy range 6 GeV …
-
Direct Dark Matter Search with the DarkSide Experiment
… program: calibration strategies and event position reconstruction methods for the DarkSide-20k detector, and a heavy dark matter (HDM) search with DarkSide-50, in which the case of composite HDM with varying dark nucleon masses is considered for the first time in the dual-phase argon TPCs.
-
A Data-Driven Method for Measuring Position Resolution in the DEAP-3600 DarkMatter Detector
… of the acrylic vessel, achieved through means of position reconstruction and a fiducial cut on the reconstructed spherical radius. Understanding the precision of the reconstruction is therefore vital to knowing its effectiveness and so the goal of this project was to develop a method of measuring …
-
Optimization of a compact medical gamma camera
… of the model was confirmed by a very accurate reconstruction of the experimental event positions using the LRFs calculated from the simulated data. An optimization study was performed on the lightguide thickness for several configurations. It was shown that the optimal configuration of the …
-
A measurement of the surface radioactivity and its time dependence in the SNO+ detector
… the detector surface and its influence on event position reconstruction is investigated. A novel methodology is introduced to detect mis-reconstructed events, effectively mitigating the issue. Mis-reconstruction is eliminated within a radius of 5.1m from the detector center and significantly …
-
Research and development of a segmented GEM readout detector
… for this. Secondly, a unique 2D particle position reconstruction is only possible if the detector is hit by only one particle at the same time. If multiple particles arrive simultaneously a unique X-Y assignment is strongly aggravated. This can be compensated by GEM strips rotated 45° to …
-
Developing Algorithms for Bubble Identification and Tracking for the PICO-40L Dark Matter Experiment
… of convection within the active fluid. The position reconstruction agreed well with to the calculated terminal velocity of the bubbles. An asymmetry in the vertical velocity was observed within the bulk of the detector indicating the presence of convection within the active volume, which …
-
MITIGATION of BACKGROUNDS for the LARGE UNDERGROUND XENON DARK MATTER EXPERIMENT
… from the target xenon is described in depth. A position reconstruction algorithm based on comparison of observed data to simulation is developed. Background events from the detector's internal walls are studied and modeled for the profile likelihood ratio test of the second analysis. Finally, …
Page 1 of 3