Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 40 for “"Positioning device"”.
-
NEST: Portable Seating and Positioning Device
Abstract Seating and positioning are essential components of wheelchair technology that provide comfort, support, and protection for the user throughout all of their Activities of Daily Living (ADLs). These components are even more crucial for nonambulatory, full-time wheelchair users, and/or those …
-
Wearable Multi-Sensor Positioning Device for Rowing Technique Analysis
… the feasibility of a wearable multi-sensor positioning device to be used as a training tool to evaluate rowing technique, and to determine the positioning accuracy using multiple mathematical models and estimation methods. The wearable device consists of an inertial measurement unit, an …
-
Active surgical positioning device for a cochlear implant electrode array
… project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a …
-
Development of a Positioning Device for use in Conjunction with Panoral Radiography
A cephalometric positioning device has been developed for use on the XRM Panorex X-Ray machine. Tests have demonstrated that the variability in producing serial radiographs with this device is comparable to, or less than, that currently accepted in conventional radiographic cephalometry. Two …
-
REALIZATION OF A CANINE POSITIONING DEVICE FOR IN SITU PROSTATE PHASE CONTRAST – COMPUTED TOMOGRAPHY IMAGING
… development and implementation of a canine positioning device used for in situ prostate PC-CT imaging on the Biomedical Imaging and Therapy –Insertion Device Beamline at the Canadian Light Source. This device is currently being used to collect micron-level resolution PC-CT reconstructions of …
-
Design of a 2D MRI compatible robot for performing prostate cancer treatment using therapeutic ultrasound
… In this thesis a prototype MRI compatible positioning device for the treatment of prostate cancer using therapeutic ultrasound is presented. The accuracy, MRI compatibility and functionality of the positioning device was evaluated in in vitro experiments (using gel phantoms and in vitro). …
-
A Method to Determine Curved Surface laminagraphic width and position in Panoral Radiography Utilizing the Panorex X-ray Unit
… rotational axes were first located. Utilizing a positioning device, ten panoral radiographs of a plastic working dummy with metallic implants were exposed at varying exposure readings. The resultant radiographs, revealing varying degrees of accuracy and distortion, permit plotting and …
-
Discontinuous damping of relay servomechanisms.
… of a relay servo to improve its performance as a positioning device. The investigation was performed at the U.S. Naval Postgraduate School at Monterey, California during the period September, 1955 to May, 1956.
-
Precise motion with piezoelectric actuator.
… the displacement performance of a high accuracy-positioning device equipped with three piezo ceramic actuators. The displacement performance of each individual actuator is investigated in order to perform controlled motion over a very small range. A nanometric precision three-degrees of freedom …
-
Quasi-optimization of two phase induction motor relay servos.
… of a relay servo to improve its performance as a positioning device. The torque element of the servo is a two phase induction servomotor. The investigation was conducted at the U. S. Naval Postgraduate School at Monterey, California, during the period September, 1956, to May, 1957. The …
-
A Technique for Studying the Spacial Relationship of Oral Hard Tissues Utilizing Panoral Radiography
… of the Panorex machine. This time the auxiliary positioning device was completely disassembled and reassembled before each exposure. These films were superposed and photographic evidence documents the acceptability of the auxiliary device for positioning the patient. An contact exposure was made …
-
The accuracy of charted port positions in the Pacific as defined by satellite determined positions using multiple observations
… (MX 702/hp) Satellite Navigator as a fixed point positioning device. While it is apparent that not all positions were determined to the same accuracy, a significant number represent improvements of 15 seconds or more in the charted positions of islands, ports and harbors in the Pacific basin. Thus …
-
Clinical Photographic Analysis of Dentofacial Midline Asymmetries
… Polaroid intraoral camera (Unitek) with a positioning device used to relate the facial midline to the maxillary arch photograph. Orthodontic patients with midline discrepancies were assessed by both methods. The study indicated that photo analysis had minimal advantage over direct …
-
Investigation of skin dose in megavoltage radiation therapy for breast cancer.
… a higher radiation dose than necessary. B positioning during radiation therapy to reduce skin folds may provide further reduction in unnecessary skin dose. Furthermore, better breast positioning may also lead to reduction in the volume of normal tissues irradiated, further benefitting the …
-
Screw fixation of implants to the spine
… confirmed the potential for a simple screw positioning device and identified the need for an improved screw for osteoporotic bone. Determination of the compressive mechanical properties of 0.32 g.cm\(^{-3}\), 0.16 g.cm\(^{-3}\) and 0.09 g.cm\(^{-3}\) polyurethane foam enabled them to be used …
-
Modeling of a Patient Positioning System for use in MRI Machines
… hardware and expanded the intended uses for MRI devices over time. However, MRI manufacturers have not improved the design of the mechanisms and control schemes used to move the patient.Patient positioning systems are required to handle unknown weights up to 225 kilograms, accommodate friction …
-
SYNCHROTRON RADIATION INLINE PROPAGATION BASED PHASE CONTRAST COMPUTERIZED TOMOGRAPHY (PC-CT) OF HUMAN PROSTATE SAMPLE
… the biomedical imaging and therapy – insertion device (BMIT-ID) beamline of Canadian light source (CLS) beamline was 1,481.7 mSv, which is very high compared to the standard clinical CT examination deposits in human clinical medicine. The dose could be reduced by performing sparse view imaging …
-
Fabricação local de um protótipo de um bico injetor diesel common rail EURO 5
… have been documented and are reproducible. A device was built which allowed to perform the internal grinding of the guide hole of the needle of the injection nozzle in a CNC lathe. A positioning device was also built to ensure the pitch and roll angles of the atomizer nozzles in the …
-
Modeling and robust adaptive control of metal cutting via application of piezoactuator
… the cutting system as an important controllable positioning device for ultra-precision machining. With the application of piezoactuator, a much more accurate model is required for achieving the ultra-precision control. In this thesis, rather than using the commonly accepted linear Merchant model, …
-
Effect Of Occlusal Vertical Dimension On Lip Positions At Smile
… articulators. A wall-mounted head positioning device, modified from a cephalometric unit was used to stabilize head positions. Three photographs each at OVD of +0mm, +2mm, +4mm, +6mm, +8mm were taken using a DSLR camera mounted on a tripod. Measurements were made in Adobe Photoshop …
Page 1 of 2