Results 1 to 7 of 7 for “"Post-frame"”
-
Bracing requirements for post-frame endwalls
… diaphragm action is considered in the design of post-frame buildings, the endwalls may require supplemental reinforcement to replace lost strength and stiffness, due to placement of large doors and openings in the endwalls. The diaphragm design standard, ASAE EP484, does not provide guidelines …
-
Correlation of roof loads to wind speed and direction on a post-frame building in real time
In 2004 a post-frame structure with plastered straw bales as an in-fill wall system was built at the University of Manitoba. Load cells installed at the top and bottom of ten eave wall posts were intended to measure the tributary load transferred from the roof structure into the supporting posts. …
-
Methodology for the Design of Timber Frame Structures Utilizing Diaphragm Action
Modern timber frame buildings are a unique combination of ancient carpentry techniques coupled with one of the newest enclosure systems found on construction sites around the world. Contemporary timber frame structures typically utilize structural-insulated panels (SIPs) attached to a timber frame …
-
Development and assessment of non-destructive evaluation techniques for the measurment of stress and strain in biological materials
… for more accurate strain measurement in light-framed structures, the predictive calculations and structural modelling of a post-framed building was compared to its demonstrated performance. The analysis did not adequately reflect the actual performance of the building, and it was determined …
-
Evaluation of light-gauge metal diaphragm behavior and the diaphragms interaction with post frames
<p>Light-gauge steel sheeted diaphragms on wood frames may be used to transfer in-plane shear forces to the end walls in post frame structures. The amount of shear force transferred is dependent upon the in-plane stiffness of the diaphragm and the frame stiffness;The results of 31 full-scale …
-
Strength and Stiffness of Metal-Clad Roof Sections
Post-frame timber construction has gained popularity with architects and designers in recent years because of design flexibility and cost effectiveness. Beside [sic] being economically feasible, improved strength and stiffness especially with the utilization of diaphragm action was achieved. The …