Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 160 for “"Potentiostat"”.

  1. Micro-Controller Based Potentiostat

    … and decreases cost of operation. An embedded potentiostat to detect the concentration of a chemical species was built as part of an effort to remotely detect and monitor environmental contaminants. A potentiostat is an electronic instrument that allows the application of voltage waveforms of …

    boise Repository record for Micro-Controller Based Potentiostat (opens in a new tab)

  2. Program development and analysis of computer operated potentiostat

    <p>A potentiostat was designed and built, with modifications incorporated in response to analysis of performance, with the objective of maximizing the capabilities of its operation through real-time computer control with minimum investment in potentiostat hardware. Extensive software was developed …

    ut-knoxville Repository record for Program development and analysis of computer operated potentiostat (opens in a new tab)

  3. Cybernetic Control of an Electrochemical Repertoire (Potentiostat, Instrumentation, Adsorption)

    Many experimental methods have been developed to attack different problems by electrochemical means. In chemical analysis, sensitivity and selectivity may be achieved by using different methods. The availability of multiple techniques is even more important in fundamental research. Diagnostic …

    uiuc Repository record for Cybernetic Control of an Electrochemical Repertoire (Potentiostat, Instrumentation, Adsorption) (opens in a new tab)

  4. A Low-Power, Highly Stabilized Three-Electrode Potentiostat Using Subthreshold Techniques

    … CO<sub>2 </sub>[carbon dioxide], pH, etc. Potentiostats are essential components of electrochemical sensors such as glucose monitoring devices for diabetic patients. Diabetes is a metabolic disorder associated with insufficient production or inefficient utilization of insulin. The most …

    utk-theses Repository record for A Low-Power, Highly Stabilized Three-Electrode Potentiostat Using Subthreshold Techniques (opens in a new tab)

  5. Electrospun Nanofibrous Membrane Based Glucose Sensor with Integration of Potentiostat Circuit

    … 3) Integration of proposed chronoamperometric potentiostat (TIA and VCU) with glucose sensors to use it later for implantable bio-medical devices and In-vivo applications. Electrochemical enzymatic biosensors have become popular for point-of-care monitoring of glucose levels in the blood. The …

    usf Repository record for Electrospun Nanofibrous Membrane Based Glucose Sensor with Integration of Potentiostat Circuit (opens in a new tab)

  6. Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito

    … addition of a new programmable electrochemical potentiostat. This addition reduces the number of components integrating the glucometer and maximize the accuracy of the glucose detection in the E-Mosquito when evaluating a blood sample. In the needle study, six out of eight tests extracted the …

    calgary Repository record for Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito (opens in a new tab)

  7. Wide Dynamic Range, Highly Accurate, Low Power CMOS Potentiostat for Electrochemical Sensing Applications

    … factors such as lactate, oxygen, and pH. A potentiostat is an integral part of a glucose sensor that controls the potential difference between the two electrodes and acquires sensor signals for the signal processing unit that collects and processes the data to transmit to a wireless device. …

    ut-knoxville Repository record for Wide Dynamic Range, Highly Accurate, Low Power CMOS Potentiostat for Electrochemical Sensing Applications (opens in a new tab)

  8. Shewanella loihica PV-4 electroactive biofilms (EABs) grown in potentiostat-controlled electrochemical cells.

    … characterization in S. loihica PV-4 biofilms in potentiostat-controlled three-electrode cells was achieved. Different electrode materials were used, as well as chemical (carbon nanotube coating and atmospheric air plasma treatments) and physical (surface abrasion) treatment of the electrode, …

    dcu Download PDF for Shewanella loihica PV-4 electroactive biofilms (EABs) grown in potentiostat-controlled electrochemical cells. (opens in a new tab)

  9. Development of a computer controlled multichannel potentiostat for applications with flowing solution analysis

    A 16-channel computer controlled potentiostat has been designed for use with an amperometnc array for analysis in flowing streams The instrumentation developed to date has been used with both linear and radial flow cell configurations which have been constructed "m-house" Analogue and digital …

    dcu Download PDF for Development of a computer controlled multichannel potentiostat for applications with flowing solution analysis (opens in a new tab)

  10. A versatile low-cost microcontroller-based 4-channel potentiostat platform for electrochemical biosensor development

    … of analyte detection in different body fluids. A potentiostat is the instrument used to control the applied potential and measure current flow in the electrochemical cell, where the analyte detection reaction occurs. Advances in electronics and microcontrollers have enabled such sophisticated …

    bu Repository record for A versatile low-cost microcontroller-based 4-channel potentiostat platform for electrochemical biosensor development (opens in a new tab)

  11. Optimizing and Validating the Performance of a Low-cost Potentiostat for In-Situ Flow Battery Testing

    … and Validating the Performance of a Low-cost Potentiostat for In-Situ Flow Battery Testing Dharik Purohit This thesis relates to the design, optimization, and validation of a low-cost potentiostat tailored specifically for the requirements of flow battery testing. The primary objective is to …

    concordia Download PDF for Optimizing and Validating the Performance of a Low-cost Potentiostat for In-Situ Flow Battery Testing (opens in a new tab)

  12. Low-Voltage Bulk-Driven Amplifier Design and Its Application in Implantable Biomedical Sensors

    … of analytic systems, analog circuits such as the potentiostat are not amenable to either low-voltage operations or short channel transistor scheme. To date, several proposed low-voltage design techniques have not been adopted by mainstream analog circuits for reasons such as insufficient …

    utk-theses Repository record for Low-Voltage Bulk-Driven Amplifier Design and Its Application in Implantable Biomedical Sensors (opens in a new tab)

  13. Design and Implementation of Signal Processing Circuitry for Implantable Sensors

    … inconvenience caused to diabetic patients. A potentiostat forms an integral part of a sensor signal processing circuit. In this thesis the design and simulation of an on-chip potentiostat circuit has been presented. A potentiostat is needed to maintain a constant potential, so that the sensor …

    ut-knoxville Repository record for Design and Implementation of Signal Processing Circuitry for Implantable Sensors (opens in a new tab)

  14. A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller

    … commercial electrochemical analyzers like potentiostats primarily operate as black boxes with manufacturers providing little or no information about internal circuitry and programming. This practice can limit a researcher’s ability to develop new techniques or adapt an instrument for …

    etsu Repository record for A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller (opens in a new tab) Download PDF for A Low Cost, Compact Electrochemical Analyzer based on an Open-Source Microcontroller (opens in a new tab)

  15. Development of a DNA biosensor to detect antimicrobial resistance

    … electrode substrates, as well as on a low-cost potentiostat system which could provide a cost effective, self-contained diagnostic platform. DNA targets are detected on each of these systems, and performance of the low-cost potentiostat is shown to be comparable to a benchtop potentiostat. A …

    strathclyde Repository record for Development of a DNA biosensor to detect antimicrobial resistance (opens in a new tab)

  16. Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems

    … relevant glucose levels.</p> <p>Second, novel potentiostat topologies based on a difference-differential common gate input pair transimpedance amplifier and low-power voltage controlled oscillators have been proposed, mathematically modeled and implemented in a 0.18μm [micrometer] complementary …

    utk-theses Repository record for Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems (opens in a new tab)

  17. The corrosion of CoCrMo alloys for biomedical applications

    … cell in this study of tribocorrosion. OCP and potentiostat measurements were taken using 3.5% NaCl and 28% bovine in the hip simulator. Potentiodynamic polarisation curves were taken in neutral and acidified bovine serum solutions. The problems and changing variables that occur as a result of …

    birmingham Download PDF for The corrosion of CoCrMo alloys for biomedical applications (opens in a new tab)

  18. Design And Characterization Of An Embedded Amperometric Analyzer For Field-Portable Electrochemical Applications

    … Inside the amperometric analyzer, a mini-potentiostat is designed to interface with a wide spectrum of electrochemical sensors. Implemented with grounded-auxillary electrode configuration, the mini-potentiostat controls oxidationreduction reactions of target analytes at the working …

    cornell Repository record for Design And Characterization Of An Embedded Amperometric Analyzer For Field-Portable Electrochemical Applications (opens in a new tab)

Page 1 of 8