Showing 1 to 20 of 106 for “"Power Transformer"”.
-
Machine learning for power transformer diagnostics
Electric power system transformers are significant and high capital grid and network assets which require condition monitoring and pre-emptive assessment for ongoing resource management and regular maintenance. Among the myriad of methods suitable for transformer assessment, dissolved gas analysis …
-
Predicting Power Transformer Bushings' Seismic Vulnerability
… is at risk due to the vulnerability of large power transformers’ insulating bushings, which can experience dramatic seismic amplification. Identifying cases where this risk exists is critical if we are to mitigate against potentially expensive, extensive, and long-lasting power outages …
-
Power transformer magnetization under GIC/GMD
… induced currents (GIC) could saturate a transformer core. Two significant effects are the abnormal stray flux in transformers and extremely large harmonic contents in excitation currents, which can lead to serious equipment damage and power system misoperation. Such incidents have …
-
Security Enhancement of Power Transformer Differential Protection
… and communication technologies (ICTs) in power grid operational environments has been essential for operators to improve the monitoring, maintenance and control of power generation, transmission and distribution, however, at the expense of an increased grid exposure to cyber threats. …
-
The Modernization of Large Power Transformer Tanks
<p>Due to the current demands placed on the power grid in terms of climate change, increasing urbanization, and terrorist attacks, the U.S. government in response to these demands, mandated that all the grid components be modernized in order to increase their reliability. As a critical component of …
-
Optical Temperature Monitoring of Electrical Power Transformer Networks
… network model designed to monitor temperature of transformers at multiple substations from one central location. Fiber Bragg Grating (FBG) has been used as the optical sensing element for transformer temperature monitoring. Suitable FBG parameters and specifications have been investigated and …
-
Amorphous metal cores in medium frequency power transformer
… for the corematerial in medium frequency power transformers. The amorphousmetal provides such savings by its ability to operate at highflux densities without excessive core losses. The reduced coresize also benefits the winding size, the overall reduction inweight and volume is …
-
Power Transformer Transient Modeling Using Frequency Response Analysis
… data of a 13.8 kV/136.8 kV, 50-MVA single phase transformer. The frequency response of the primary and secondary coils as well the coupling between the coils have been measured in the frequency range of up to 2 MHz. The measured data includes the stray capacitances that exist between the coils. A …
-
The Design and Construction of a Power Transformer
Usually one coil of the transformer has many more turns of wire than the other, when the coil of few turns is the primary, the transformer takes a large current at a low potential and delivers a smaller current at high potential. This is called a step up transformer. When the coil of many turns is …
-
Simple Power Transformer Fiber Bragg Grating Temperature Sensor
… the sensor suitable for installation inside the power transformer. Unlike the existing fiber Bragg grating based temperature sensors, the interrogation system of the sensor is based on amplitude modulation (AM). The distinctive characteristics of the designed temperature sensor, in addition to …
-
Parameter estimator and observer design for power transformer diagnostics
Includes bibliographical references (pages 129-133).
-
Power Transformer Frequency Response Analysis: Examination of Resonance Influences on Frequency Response Analysis Signals as The Traveling Wave is Transmitted Through a Power Transformer
Understanding the physics associated with power transformer frequency response analysis (FRA) is required to properly interpret FRA traces for correct diagnostics of a power transformer. Events occurring within a power transformer to influence FRA test traces are explained. A complex Lorentzian …
-
The Design and Construction of a 500 Watt Power Transformer
… in the design and construction of small transformers for radio transmitting stations. The author is indebted to Dp. Charles A. Perkins for ideas and suggestions which were of considerable help in designing the transformer and to the Knoxville Power and Light Company for furnishing the …
-
Developments for the high frequency power transformer design and implementation
… manufacturing of ferrite based high frequency power transformers. The primary aim of the work was to study core and winding losses and in particular thermal modeling of high frequency power transformers and to determine appropriate loss and temperature rise modeling methods for power converter …
-
A wavelet-based restricted earth-fault power transformer differential protection
In order to enhance power transformer differential protection, especially with respect to its reliability and speed, several schemes have been proposed in the last years. Faults inside the transformer protection zone may cause critical damages to this device if its protection unit does not operate. …
-
Intelligent Condition Assessment of Power Transformer Based on Data Mining Techniques
… years, the trade-off between quality and cost of power system components has become a matter of interest for many utilities. The widespread use of costly electricity networks either in residential or industrial areas has encouraged service providers to find a proper strategy that will minimize the …
-
Influence of contamination on the electrical performance of power transformer oil
Transformer failure statistics from all over the world showed that almost 30% of them were due to insulation. Large amount of those failures were due to particles in transformer oil. Main focus of this research is to effects of contamination on electrical performance of transformer oil. A …