Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 100 for “"Power cables"”.

  1. Partial discharge denoising for power cables

    … for the monitoring of insulating conditions of power cables. As such, a large amount of off-line or online PD measurements have been deployed in power cables during the past decades. However, challenges still exist in PD diagnostics for power cables. Noise is one of the challenges involved in PD …

    strathclyde Repository record for Partial discharge denoising for power cables (opens in a new tab)

  2. Crack propagation in dynamic power cables

    … land. This step is carried out by dynamic subsea cables. Their service life is crucial for the profit of these solutions. The presence of water molecules in the insulating material causes a crack filled with water called a water tree, which grows with time and decreases the service life of these …

    chalmers Repository record for Crack propagation in dynamic power cables (opens in a new tab)

  3. High Power Cables in Electric Vehicles - Analysis of Optimization of High Power Cables Design for both DC and AC in Electric Vehicles

    … are introducing electric and hybrid powertrains. However, the electric and hybrid powertrains have new issues to deal with, such as electromagnetic interference (EMI) and current ripple generated by the electric drive. To address these issues the manufacturer Volvo has started the …

    chalmers Repository record for High Power Cables in Electric Vehicles - Analysis of Optimization of High Power Cables Design for both DC and AC in Electric Vehicles (opens in a new tab)

  4. EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES

    … the condition of the insulation of underground power cables was investigated. It involved removing sh011, one and a half metre long, sections from service aged cables for electrical testing. The purpose of these tests was to establish whether tests on short samples of cables can provide a …

    nus Repository record for EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES (opens in a new tab) Download file for EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES (opens in a new tab)

  5. Thermal aging investigations of medium-voltage extruded power cables

    Medium Voltage (MV) extruded power cables play a vital role in electric power transmission and distribution systems. Insulation of power cables is essential for cables’ lifetime, effectiveness, and reliability within the power cable system. However, insulation materials degrade progressively due to …

    strathclyde Repository record for Thermal aging investigations of medium-voltage extruded power cables (opens in a new tab)

  6. The echo ranger : a fault locator for power cables

    The location of faults in low-attenuation coaxial cables and open-wire lines by the use of the echo-ranging techniques of radar prompted this investigation of a method to accurately locate faults in underground power cables. As the propagation-velocity of disturbances on a smooth line or cable is …

    ubc Repository record for The echo ranger : a fault locator for power cables (opens in a new tab) Download PDF for The echo ranger : a fault locator for power cables (opens in a new tab)

  7. The potential impacts of submarine power cables on benthic elasmobranchs

    … Marine sources of renewable energy, and other power transmission requirements, use submarine power cables that are either alternating current (AC) or direct current (DC). Both have the potential to generate weak electromagnetic fields (EMFs) within the elasmobranch sensitivity range. Thus the …

    auckland-ms Repository record for The potential impacts of submarine power cables on benthic elasmobranchs (opens in a new tab)

  8. Location of faults in power cables by fault-generated surges

    … locating high-impedance faults in underground cables. Most methods of locating faults require that the fault-impedance be reduced to a low value before the measurement can be made. After a careful investigation of the available literature, it was decided that the most desirable method would be …

    ubc Repository record for Location of faults in power cables by fault-generated surges (opens in a new tab) Download PDF for Location of faults in power cables by fault-generated surges (opens in a new tab)

  9. Environmental controls on the operating temperature of marine power cables

    … cable ampacities for marine high voltage cables is currently the subject of significant industry and academic reassessment to optimise design (maximise load while maintaining safe operating temperatures) and reduce costs. The ampacity rating limits the maximum current that can be safely …

    soton Download PDF for Environmental controls on the operating temperature of marine power cables (opens in a new tab)

  10. Propagation of high frequency partial discharge signal in power cables

    The insulation lifetime of power cables is determined by several factors. One of the most important of these is the occurrence of partial discharge (PD) at the dielectric. The ability to detect and locate a PD source is limited by attenuation of the high frequency PD pulses as they propagate …

    unsw Repository record for Propagation of high frequency partial discharge signal in power cables (opens in a new tab)

  11. Ice accumulation detection on electrical power cables based on computer vision

    Ice storms can cause major power disruptions and detection of ice formation on power cables can help on taking actions for removing the ice before a major problem occurs. A computer vision solution was developed to detect ice on difficult imaging scenarios where illumination and variety of …

    manitoba Repository record for Ice accumulation detection on electrical power cables based on computer vision (opens in a new tab)

  12. Non-intrusive condition monitoring of power cables within the industrial sector

    … amount of research is dedicated to this field. Power cables are one of the most important parts of any electrical network and the variety of techniques available for CM of electrical cables is therefore no surprise. Electrical cables are exposed to operational and environmental stressors which …

    nwu-za Repository record for Non-intrusive condition monitoring of power cables within the industrial sector (opens in a new tab)

  13. Space charge measurement in polymer insulated power cables using the PEA method

    … attempts to apply the technique to polymeric cables, but it has been hampered by experimental difficulties in achieving a universal electrode system to maintain an intimate contact between the curved ground electrode, transducer and absorber.</p><p>In this research, a modified system employing …

    soton Download PDF for Space charge measurement in polymer insulated power cables using the PEA method (opens in a new tab)

Page 1 of 5