Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 31 for “"Powered Prosthesis"”

  1. Characterizing the Visuomotor Behaviour of Upper Limb Body-Powered Prosthesis Users

    … upper limb prosthetic technologies (namely, body-powered prostheses) is not well understood. The primary objective of this thesis work was to characterize the visuomotor behaviour of a sample of body-powered prosthesis users to better understand current demands of traditional prostheses, as a …

    alberta Repository record for Characterizing the Visuomotor Behaviour of Upper Limb Body-Powered Prosthesis Users (opens in a new tab)

  2. Bayesian nonparametric methods for dynamics identification and segmentation for powered prosthesis control

    … control problem which speaks of the need for powered prostheses to have anthropomorphic adaptive capabilities. However, it is inconceivable that all possible movements, dynamics and tasks can be preprogrammed into such a system. Prostheses, like robots, need to be able to learn and improve, …

    oxford Repository record for Bayesian nonparametric methods for dynamics identification and segmentation for powered prosthesis control (opens in a new tab)

  3. Revealing Key Movement Strategies in Upper Limb Function Using a Novel Standardized Kinematic Assessment Tool

    … available to evaluate functional capabilities of prosthesis users. However, current clinical assessments are lacking in the ability to quantify how specific prosthetic technologies influence biomechanical movement strategies. Kinematic assessments using motion capture technology could fill this …

    alberta Repository record for Revealing Key Movement Strategies in Upper Limb Function Using a Novel Standardized Kinematic Assessment Tool (opens in a new tab)

  4. Optimal powered ankle-foot prosthesis torque profiles to improve walking performance for individuals with a unilateral transtibial amputation

    … prescribed passive devices. Consequently, powered prosthetic devices have been developed; however, it is unclear how to optimally tune them to improve walking performance. Thus, the purpose of this study was to identify the optimal ankle torque profile of a powered ankle-foot prosthesis …

    texas Repository record for Optimal powered ankle-foot prosthesis torque profiles to improve walking performance for individuals with a unilateral transtibial amputation (opens in a new tab)

  5. Transverse-Plane Ankle Rotation for Lower-Limb Amputees Using Two Novel Prostheses

    … often suffer from pain and discomfort caused by prosthesis use. Problems include musculoskeletal issues caused by compensatory gait patterns and skin injuries caused by shear stress at the interface between the residual limb and the socket. Torsion adapters have been shown to relieve these skin …

    washington Repository record for Transverse-Plane Ankle Rotation for Lower-Limb Amputees Using Two Novel Prostheses (opens in a new tab)

  6. An assessment of lower-limb joint quasi-stiffness during healthy and transtibial amputee walking

    … limb compensations when wearing a passive or powered prosthesis, since unlike passive prostheses, powered devices can mimic muscle force generation. A tradeoff in intact hip and ankle demand suggested a shift towards cautious gait when carrying an anterior load, and improved ankle work …

    texas Repository record for An assessment of lower-limb joint quasi-stiffness during healthy and transtibial amputee walking (opens in a new tab)

  7. Whole-body angular momentum during walking on stairs using passive and powered lower-limb prostheses

    … ascent and descent in TTA using passive and powered prostheses compared to AB. The range of H was generally reduced in TTA and AB during descent relative to ascent, which may be a mechanism to reduce fall risk during descent. TTA using both types of prostheses had an increased range of …

    colo-mines Repository record for Whole-body angular momentum during walking on stairs using passive and powered lower-limb prostheses (opens in a new tab)

  8. Optimization of transverse flux motor for utilization in bionic joints

    Though there have been remarkable advances in powered prosthesis technology over the past decade, design limitations of commercial electric motors are one of the main bottlenecks in meeting critical device requirements, such as minimum range on a single battery charge and acoustic emission …

    mit Repository record for Optimization of transverse flux motor for utilization in bionic joints (opens in a new tab)

  9. Powered Transtibial Prosthetic Device Control System Design, Implementation and Testing

    A powered lower limb prosthesis, which consists of a four bar mechanism, a torsional spring and a brushed DC motor, was previously designed and fabricated. To regulate the motor power input, a two level controller was proposed and built. The control algorithm includes a higher level finite state …

    marquette Repository record for Powered Transtibial Prosthetic Device Control System Design, Implementation and Testing (opens in a new tab)

  10. Design and Implementation of the Powered Self-Contained AMPRO Prostheses

    … methodology for translating robotic walking to powered prostheses, and demonstrates this framework on two novel custom built powered prostheses, AMPRO. Motivated by methods that have successfully generated dynamically stable walking gaits on bipedal robots, reference human locomotion data is …

    tamu Repository record for Design and Implementation of the Powered Self-Contained AMPRO Prostheses (opens in a new tab)

  11. Design and Prototype Validation of a Laterally Mounted Powered Hip Joint for Hip Disarticulation Prostheses

    Powered prostheses are at the forefront of prosthetic technology, improving functionality by providing positive power to joints in the absence of native anatomy. Currently, there is no commercially available powered solution for hip-level amputees, and most hip prostheses are mounted to the front …

    ottawa-retro Repository record for Design and Prototype Validation of a Laterally Mounted Powered Hip Joint for Hip Disarticulation Prostheses (opens in a new tab)

  12. Design and development of a sensory feedback system for transradial amputees using body powered prostheses

    … advancements have been made in the realm of prosthesis design over the last two decades, amputees still reject their prostheses largely owing to the lack of sensory feedback received. The aim of this study was to develop a non-invasive sensory feedback system, including proprioceptive …

    cape-town Repository record for Design and development of a sensory feedback system for transradial amputees using body powered prostheses (opens in a new tab)

  13. Optimal Design and Control of a Lower-Limb Prosthesis with Energy Regeneration

    … for lower-limb prostheses. Many common prosthesis designs are passivein nature, making them inefficient compared to the natural body. Recently as technologyhas progressed, interest in powered prostheses has expanded, seeking improvedkinematics and kinetics for amputees. The current state …

    ohiolink Repository record for Optimal Design and Control of a Lower-Limb Prosthesis with Energy Regeneration (opens in a new tab)

  14. Design and Testing of an Externally Powered Elbow Prosthesis

    There continues to be a need for an externally powered prothesis which can be used by above elbow amputee patients who cannot effectively operate a conventional body powered prosthesis. This device must be reliable, economically constructed, and easily maintained in the field. A device employing a …

    nodak Repository record for Design and Testing of an Externally Powered Elbow Prosthesis (opens in a new tab)

  15. Improving Intelligence of Robotic Lower-Limb Prostheses to Enhance Mobility for Individuals with Limb Loss

    … easily adapt to changing environmental contexts. Powered prostheses have shown promise to help restore the necessary power needed to walk in common ambulatory tasks. However, there is a need to infer/detect the user's movement to appropriately provide seamless and natural assistance. To achieve …

    gatech Repository record for Improving Intelligence of Robotic Lower-Limb Prostheses to Enhance Mobility for Individuals with Limb Loss (opens in a new tab)

  16. Control of a Human Arm Robotic Unit Using Augmented Reality and Optimized Kinematics

    … prostheses. Research on 6-7 degree of freedom powered prostheses is still relatively new, and most commercially available powered prostheses are typically limited to 1 to 3 degrees of freedom. Due to the myriad of possible options for various powered protheses from different manufacturers, each …

    usf Repository record for Control of a Human Arm Robotic Unit Using Augmented Reality and Optimized Kinematics (opens in a new tab)

  17. Transfemoral Prosthesis Control for Inclined Walking Using Impedance Control and Bezier Polynomial Based Optimization

    A powered transfemoral prosthesis is an assistive device for patients with above knee amputation. For these patients, walking on various sloped surfaces is one of the most challenging tasks in their daily lives. Designing prostheses that can effectively adapt to varying terrain remains an ordeal to …

    tamu Repository record for Transfemoral Prosthesis Control for Inclined Walking Using Impedance Control and Bezier Polynomial Based Optimization (opens in a new tab)

  18. Reducing Socket Discomfort and Torsional Stresses for Individuals With Lower-Limb Amputation Using a Novel Prosthesis

    … socket-residual limb interface after using their prosthesis. A portion of this pain and discomfort can be isolated to the transverse plane. It has been shown that the inherent geometry of the bones in the ankle joint produce motion in the transverse plane; however, prosthetic limbs generally only …

    washington Repository record for Reducing Socket Discomfort and Torsional Stresses for Individuals With Lower-Limb Amputation Using a Novel Prosthesis (opens in a new tab)

  19. Impact of prehensor stiffness on quality of haptic feedback in body-powered upper limb prostheses

    The design goal of a prosthesis is to replicate or replace the lost functionality of the missing limb. However, currently available upper limb prosthetic devices generally fall short of this goal, and as a consequence are often abandoned or rejected by the users. Potentially contributing to this …

    colo-mines Repository record for Impact of prehensor stiffness on quality of haptic feedback in body-powered upper limb prostheses (opens in a new tab)

  20. Sensor fusion for predictive control of human-prosthesis-environment dynamics in assistive walking

    Powered prostheses are effective for helping amputees walk on level ground, but these devices are inconvenient to use in complex environments. To address the above issue, the present thesis develops a sensor fusion system in a complete human-prosthesis-environment loop to recognize the …

    ubc Repository record for Sensor fusion for predictive control of human-prosthesis-environment dynamics in assistive walking (opens in a new tab)

Page 1 of 2