Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"Pre-amplifier"”.

  1. Low Noise Pre-amplifier/Amplifier Chain for High Capacitance Sensors

    … is essential for detector systems. A low noise pre-amplifier/amplifier readout circuitry has been designed and fabricated in 0.13um IBM CMOS8RF process technology. The pre-amplifier/ amplifier chain employs correlated double sampling at the input to suppress the kTC noise without any additional …

    maryland Repository record for Low Noise Pre-amplifier/Amplifier Chain for High Capacitance Sensors (opens in a new tab)

  2. A transistorized relay servo

    … power transistors and a simple transistorized pre-amplifier. A permanent magnet, DC motor is used as a test vehicle to illustrate the feasibility of control without an amplidyne or mechanical relay. The "bang-bang" capability of the controller to operate as a near-ideal "relay" is emphasized. …

    nps Repository record for A transistorized relay servo (opens in a new tab)

  3. Design of a low-voltage, low-noise dynamic comparator and a 10-bit 8-MS/s time-assisted SAR ADC

    … CDAC switching process are reviewed. The work presents proposals of a dynamic comparator topology, a SAR ADC topology with a hybrid dynamic comparator and another SAR ADC design with an original CDAC switching scheme. The proposed low-voltage dynamic comparator for low-power ADC applications …

    brazil-ufrgs Repository record for Design of a low-voltage, low-noise dynamic comparator and a 10-bit 8-MS/s time-assisted SAR ADC (opens in a new tab)

  4. 2 um Lasers for Cryogenic-Silicon Gravitational Wave Detectors

    … μm band must therefore be developed. The preferred architecture is a master oscillator followed by a chain of power amplifiers, sometimes referred to as a master-oscillator-power-amplifier (MOPA). Additionally, the coherent combination of several high power laser beams may be required. …

    adelaide Repository record for 2 um Lasers for Cryogenic-Silicon Gravitational Wave Detectors (opens in a new tab)

  5. High Performance Circuits for Power Management and Millimeter Wave Applications

    … management and a switchable harmonic mixer with pre-amplifier and poly-phase generator as a core part of a millimeter wave receiver are proposed, implemented and experimentally measured. First, two externally compensated low drop-out voltage regulators (LDOs) with high power supply rejection …

    tamu Repository record for High Performance Circuits for Power Management and Millimeter Wave Applications (opens in a new tab)

  6. Development of a high energy diode-pumped chirped pulse amplification laser system for driving soft x-ray lasers

    … room temperature and cryogenically-cooled Yb:YAG amplifier to produce 1.5 Joule pulses at up to 50 Hz repetition rate. Pulse compression results in 1 J pulses of 5 ps duration. A room temperature pre-amplifier maintains bandwidth for short pulse operation and a novel cryogenic cooling technique …

    colostate Repository record for Development of a high energy diode-pumped chirped pulse amplification laser system for driving soft x-ray lasers (opens in a new tab)

  7. Testing and Packaging for MEMS Acoustic Emission Sensors

    … cracks in structures and to check leakage in pressurized systems. The location of cracks in a structure or system leakage causes a high-frequency surface vibration while releasing ultrasonic energy. The frequency of this energy is typically between 30 kHz to 1MHz. The AE sensor can detect this …

    usf Repository record for Testing and Packaging for MEMS Acoustic Emission Sensors (opens in a new tab)

  8. Ytterbium-doped Fiber-seeded Thin-disk Master Oscillator Power Amplifier Laser System

    … processing, directed energy and EUV generation. Presented in this dissertation is a high-power 1 μm ytterbium-based hybrid laser system with temporally tailored pulse shaping capability and up to 62 mJ pulses, with the expectation the system can scale to higher pulse energies. This hybrid system …

    ucf Repository record for Ytterbium-doped Fiber-seeded Thin-disk Master Oscillator Power Amplifier Laser System (opens in a new tab)

  9. Demonstration of a compact 100 Hz, 0.1 J, diode-pumped picosecond laser

    In this work I present an all laser diode pumped chirped pulse amplification laser system that is capable of producing 100 mJ laser pulses at 100 Hz repetition rate with durations of under 5 ps. The primary focus of this work consists of the development of two amplification stages that boost the …

    colostate Repository record for Demonstration of a compact 100 Hz, 0.1 J, diode-pumped picosecond laser (opens in a new tab)

  10. A Wireless Surface Electromyography (WSEMG) System

    … analysis may exercise multiple sensors, each representing a unique data channel, positioned about the patient's body. Data transmission cables are linked between the surface mounted sensor nodes and a backpack worn by the patient. As the number of sensors increases, the patient's freedom of …

    vcu Repository record for A Wireless Surface Electromyography (WSEMG) System (opens in a new tab)

  11. Ultra-fine signal classification using memristor-enabled hardware

    … 50mV DC offset from electrodes. The measurement presents that the memristor-based pre-amplifier is capable of achieving above 95% spike detection accuracy with hundreds of nanowatt power consumption per channel. This design indicates a promising approach to conduct spike-detection on-chip with …

    soton Download PDF for Ultra-fine signal classification using memristor-enabled hardware (opens in a new tab)

  12. Magic Angle Spinning Spheres and Improved Microwave Coupling for Magnetic Resonance

    … the probe are separated along with placing the pre-amplifier in close proximity to the receive coil. This design can lead to an improved signal-to-noise ratio. The improved MAS DNP NMR instrumentation will allow for sufficient sensitivity to investigate complicated biological systems.

    wustl Repository record for Magic Angle Spinning Spheres and Improved Microwave Coupling for Magnetic Resonance (opens in a new tab)

  13. Developing an Automated Explosives Detection Prototype Based on the AS&E 101ZZ System

    … hardware was developed to interface to the AS&E pre-amplifier boards, to collect image data from all three x-ray detectors, and to transfer the data to a personal computer. This hardware, the Differential Pair Interface Board (DPIB), is based on a Field Programmable Gate Array (FPGA) and can be …

    vt Repository record for Developing an Automated Explosives Detection Prototype Based on the AS&E 101ZZ System (opens in a new tab)

  14. Characterization of Optimized Si-MOSFETs for Terahertz Detection

    … low noise setup comprising of a lock-in amplifier, low noise current pre-amplifier, and various low noise techniques has been assembled. Different biasing conditions and temperature were used to analyze the mechanisms of detection and find the best operating parameters. The devices that …

    rit Repository record for Characterization of Optimized Si-MOSFETs for Terahertz Detection (opens in a new tab)

  15. Caracterização de fitas supercondutoras 2G HTS em regime de Flux flow

    … and above critical current (Ic) values. Also, a pre-amplifier circuit was developed for continuous monitoring of voltage rise in the samples during the current pulse. The exponential factor N characteristics were obtained from V-I measurements for four 2G tapes models from different companies in …

    brazil-uerj Repository record for Caracterização de fitas supercondutoras 2G HTS em regime de Flux flow (opens in a new tab)

  16. Amplification of 2um squeezed light

    … light enable the reduction of quantum noise in precision interferometric measurements and are routinely employed in gravitational-wave detectors. Future gravitational-wave detector upgrades based on cryogenic silicon optics are expected to operate at longer wavelengths near 1984nm, to take …

    anu Repository record for Amplification of 2um squeezed light (opens in a new tab)

  17. Noise exposure and risk of hearing loss for Air Force welders

    … via a two-channel system using a microphone, pre-amplifier and front-end unit for each channel. The signals were saved to digital audiotape or a digital oscilloscope and then analyzed with a real time analyzer and the digital oscilloscope. One channel was used normally and the other was varied …

    colostate Repository record for Noise exposure and risk of hearing loss for Air Force welders (opens in a new tab)

Page 1 of 3