Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Precision mass measurement"”

  1. Higher precision mass measurement via the boundary of many-body phase space

    We introduce a new method of mass measurement for particles in decay chains. The method relies upon performing a likelihood analysis on the phase space of the decay in its full dimensionality in a Lorentz-invariant formulation. This method is applicable for any decay chain, but we demonstrate it …

    texas Repository record for Higher precision mass measurement via the boundary of many-body phase space (opens in a new tab)

  2. High precision mass measurement of silicon-32 and developments at the LEBIT facility

    The mass of an atom, a fundamental property, serves as a unique identier of the nucleus like a fingerprint and represents, through the binding energy, the sum of all atomic and nuclear interactions. Precise mass values are essential in many disciplines including nuclear structure and fundamental …

    msu Repository record for High precision mass measurement of silicon-32 and developments at the LEBIT facility (opens in a new tab)

  3. Multiple-Reflection Time-of-Flight Mass-Spectrometry: Not just for high precision mass measurement

    Multiple-Reflection Time-Of-Flight Mass Spectrometers (MR-TOF-MS) are a relatively new tool that has quickly become a standard instrument for high precision mass measurements in nuclear physics. The TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) MR-TOF-MS and a new technique of “post …

    manitoba Repository record for Multiple-Reflection Time-of-Flight Mass-Spectrometry: Not just for high precision mass measurement (opens in a new tab)

  4. A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches

    Precision mass measurements of exotic nuclei are indispensable for addressing key questions in nuclear physics, particularly in the search for neutrinoless double beta decay. This thesis reports the first implementation and operation of a cryogenically upgraded Penning trap system (CryoMPET) at the …

    manitoba Repository record for A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches (opens in a new tab)

  5. High-precision mass measurement of 24Si and the development of a CID gas cell (CIDGC)

    Nuclear masses have been studied for over a century, with critical data providing important constraints in nuclear physics studies. Penning trap mass spectrometry (PTMS) is one of the most precise methods for measuring the masses of exotic nuclei at rare isotope facilities. PTMS is performed at …

    msu Repository record for High-precision mass measurement of 24Si and the development of a CID gas cell (CIDGC) (opens in a new tab)

  6. Precision mass measurements of neutron-rich rare isotopes approaching the r-process path with the Canadian Penning Trap mass spectrometer

    The masses of 15 neutron-rich nuclei were measured using the Canadian Penning Trap mass spectrometer (CPT) located at the Californium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory to an average mass precision of $\delta m/m \approx 10^{-7}$. This includes masses of …

    mcgill Repository record for Precision mass measurements of neutron-rich rare isotopes approaching the r-process path with the Canadian Penning Trap mass spectrometer (opens in a new tab)

  7. High-precision atomic mass measurement of helium-4

    Penning-trap mass spectrometry enables a precise determination of atomic masses, supporting sensitive tests of fundamental physics. LIONTRAP (Light Ion TRAP) is a specialized mass spectrometer focused on precise mass measurements of light ions. In this experiment, we currently reach a relative …

    heid-diss Repository record for High-precision atomic mass measurement of helium-4 (opens in a new tab)

  8. Mass measurement of 27p to improve type-I x-ray burst models and implementation of phase imaging ion cyclotron resonance mass measurement technique

    Atomic mass measurements provide fundamental information about the nature of the nucleus due to the mass lost to binding energy in nucleosynthesis. At the Low Energy Beam and Ion Trapping (LEBIT) facility at the Facility for Rare Isotopes Beams, mass measurements of nuclei across the nuclear chart …

    msu Repository record for Mass measurement of 27p to improve type-I x-ray burst models and implementation of phase imaging ion cyclotron resonance mass measurement technique (opens in a new tab)

  9. A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al

    Penning trap mass spectrometry (PTMS) can be used to test the Standard Model (SM) and to answer the questions related to the origin and abundance of the elements in the universe. There are several facilities worldwide specialized in PTMS and some of them can measure the masses of isotopes with …

    manitoba Repository record for A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al (opens in a new tab)