Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Precision mass measurements"”.

  1. High precision mass measurements near N=Z=33

    Thesis (Ph. D.)--Michigan State University. Department of Physics, 2007

    msu Repository record for High precision mass measurements near N=Z=33 (opens in a new tab)

  2. Terra hunting: extreme precision mass-measurements of Earth like worlds

    … recent developments in technology, instrumental precision is no longer the limiting factor in detecting Earth-analogue exoplanets using the radial velocity (RV) method. Instead, the astrophysical noise caused by stellar activity can mask or, in extreme cases, mimic planetary RV motions. …

    qu-belfast Repository record for Terra hunting: extreme precision mass-measurements of Earth like worlds (opens in a new tab)

  3. Refinement of the first r-process abundance peak via high-precision mass measurements

    … form of both experimental and theoretical work. Measurements have been performed to investigate nuclei at the so-called waiting points of the r-process which result in the formation of the r-process abundance peaks. To this end, the underlying nuclear properties of the involved isotopes, …

    ubc Repository record for Refinement of the first r-process abundance peak via high-precision mass measurements (opens in a new tab)

  4. Towards high precision mass measurements of short-lived exotic isotopes using highly charged ions at the TITAN Penning trap system

    … will use Penning trap (PT) for precise mass determinations on short-lived isotopes at ISAC. An Electron Beam Ion Trap (EBIT) is used to charge breed ions to a charge state q. The PT mass resolution is directly proportional to q, resulting in a significant increase in the achieved …

    ubc Repository record for Towards high precision mass measurements of short-lived exotic isotopes using highly charged ions at the TITAN Penning trap system (opens in a new tab)

  5. An odyssey in exploring nuclei: High-precision mass measurements of exotic tin isotopes and progress toward implementing a phase-based measurement technique

    Precision mass measurements are integral in advancing our understanding of nuclear physics. Since mass is a fundamental property of nuclei. TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) facility houses two high-precision mass spectrometers designed for mass measurements of radioactive …

    uvic Repository record for An odyssey in exploring nuclei: High-precision mass measurements of exotic tin isotopes and progress toward implementing a phase-based measurement technique (opens in a new tab)

  6. Exploring magicity around N = 32 & 34 in Z >= 20 isotopes via precision mass measurements and developments with the TITAN MR-TOF mass spectrometer

    … the TITAN Multiple-Reflection Time-Of-Flight Mass Spectrometer (MR-TOF-MS) was employed to study `new' magic numbers N=32,34 across a range of isotopic chains about the traditionally magic Z=20. This work includes a characterisation of the TITAN MR-TOF-MS and high-precision mass measurements …

    whiterose Repository record for Exploring magicity around N = 32 & 34 in Z >= 20 isotopes via precision mass measurements and developments with the TITAN MR-TOF mass spectrometer (opens in a new tab)

  7. Precision mass measurements of some isotopes of tungsten and mercury for an adjustment to the mass table in the region A=184 to A=204

    … thesis concerns the precise re-measurement of mass value in the region of the mercury isotopes, such that important discrepancies in the high-mass end of the mass table could be resolved. 'Scope and contents'. Four mass spectroscopic doublets involving a comparison between 201Hg, 199Hg and 183W …

    manitoba Repository record for Precision mass measurements of some isotopes of tungsten and mercury for an adjustment to the mass table in the region A=184 to A=204 (opens in a new tab)

  8. The northern shore of the N = 40 island of inversion through precision mass measurements and developments towards phase-imaging ion-cyclotron-resonance at the TITAN MPET

    High-precision nuclear mass measurements are extremely important in furthering our understanding of the nucleus and its properties and interactions. Various different mass spectrometers exist to determine masses of nuclei far from the valley of stability to sufficient precisions, with different …

    ubc Repository record for The northern shore of the N = 40 island of inversion through precision mass measurements and developments towards phase-imaging ion-cyclotron-resonance at the TITAN MPET (opens in a new tab)

  9. Charge-breeding studies for high-precision mass measurements on short-lived nuclides at TITAN and a direct determination of the 51Cr electron-capture Q-value for neutrino physics

    Penning-trap mass spectrometry (PTMS) is a well-established technique for performing high-precision mass measurements on both stable and short-lived nuclides. Achieving high precisions with radioactive isotopes is technically challenging due to the limited yields and inherent losses from …

    ubc Repository record for Charge-breeding studies for high-precision mass measurements on short-lived nuclides at TITAN and a direct determination of the 51Cr electron-capture Q-value for neutrino physics (opens in a new tab)

  10. The buffer-gas cell and the extraction RFQ for SHIPTRAP

    SHIPTRAP is a new ion trap system for high-precision mass measurements of transuranium recoil-ions from the SHIP facility at GSI. The system consists of a buffer-gas cell to thermalise the incoming ions, an extraction system to separate the ions from the buffer gas, an RFQ buncher to cool and …

    lmu-germany Repository record for The buffer-gas cell and the extraction RFQ for SHIPTRAP (opens in a new tab)

  11. Multiple-Reflection Time-of-Flight Mass-Spectrometry: Not just for high precision mass measurement

    Multiple-Reflection Time-Of-Flight Mass Spectrometers (MR-TOF-MS) are a relatively new tool that has quickly become a standard instrument for high precision mass measurements in nuclear physics. The TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) MR-TOF-MS and a new technique of “post …

    manitoba Repository record for Multiple-Reflection Time-of-Flight Mass-Spectrometry: Not just for high precision mass measurement (opens in a new tab)

  12. Mass measurement of the lightweight self-conjugate nucleus zirconium-80 and the development of the single ion penning trap

    An atom's mass provides a unique probe to the various interactions occurring within its nucleus. Hence, precise atomic mass measurements are fundamental for nuclear physics research. Penning trap mass spectrometry (PTMS) is currently the most precise method for performing these measurements. The …

    msu Repository record for Mass measurement of the lightweight self-conjugate nucleus zirconium-80 and the development of the single ion penning trap (opens in a new tab)

  13. Towards nuclear excitation via electron capture in an electron beam ion trap

    … of the experimental hardware to perform the measurements. This thesis also presents new high-precision mass measurements for $^{33}$Mg, $^{34}$Mg, $^{35}$Mg, and $^{33}$Na. These mass measurements performed using the TITAN Multi-Reflection Time-of-flight Mass Spectrometer (MR-TOF-MS) to …

    colo-mines Repository record for Towards nuclear excitation via electron capture in an electron beam ion trap (opens in a new tab)

  14. Penning trap mass measurements to test three-body forces in atomic nuclei

    … under significant pressure since the advent of precision mass measurements is the isobaric multiplet mass equation, in which the binding energies of states in an isobaric multiplet should vary quadratically with the z-projection of the isospin. This is a consequence of the isospin dependent …

    ubc Repository record for Penning trap mass measurements to test three-body forces in atomic nuclei (opens in a new tab)

  15. High precision mass measurement of silicon-32 and developments at the LEBIT facility

    The mass of an atom, a fundamental property, serves as a unique identier of the nucleus like a fingerprint and represents, through the binding energy, the sum of all atomic and nuclear interactions. Precise mass values are essential in many disciplines including nuclear structure and fundamental …

    msu Repository record for High precision mass measurement of silicon-32 and developments at the LEBIT facility (opens in a new tab)

  16. Integration of a multi reflection time of flight isobar separator into the TITAN experiment at TRIUMF

    The TITAN experiment at TRIUMF performs high-precision mass measurements on rare isotopes using Penning trap mass spectrometry. A major challenge is the presence of isobaric contamination introduced by the rare isotope production process. To remove these a new Multi-Reflection Time-of-Flight …

    ubc Repository record for Integration of a multi reflection time of flight isobar separator into the TITAN experiment at TRIUMF (opens in a new tab)

  17. A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches

    Precision mass measurements of exotic nuclei are indispensable for addressing key questions in nuclear physics, particularly in the search for neutrinoless double beta decay. This thesis reports the first implementation and operation of a cryogenically upgraded Penning trap system (CryoMPET) at the …

    manitoba Repository record for A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches (opens in a new tab)

  18. Mass measurements of neutron-rich cobalt isotopes beyond N = 40 and the development of a single ion Penning trap mass spectrometer for rare isotopes

    … past few decades, the use of online Penning trap mass spectrometry (PTMS) has enabled precise, accurate mass measurements of rare isotopes as a probe of nuclear structure far from the valley of beta stability. As the first and only Penning trap coupled to a projectile fragmentation facility, the …

    msu Repository record for Mass measurements of neutron-rich cobalt isotopes beyond N = 40 and the development of a single ion Penning trap mass spectrometer for rare isotopes (opens in a new tab)

  19. Rehydroxylation dating

    … of issues which currently limit the precision, accuracy and robustness of rehydroxylation (RHX) dating. MC simulations and analytical expressions show that age uncertainties of previous studies are underes- timates. The ratio of sample mass to balance resolution should be of the order …

    oxford Repository record for Rehydroxylation dating (opens in a new tab)

Page 1 of 2