Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 307 for “"Precision measurements"”.

  1. Hadron structure in electroweak precision measurements.

    Precision measurements offer important, low-energy tests of the Standard Model. The Qweak and (proposed) MOLLER experiments at Jefferson Lab are two such measurements. Since the interpretation of the experimental results depends on the precision of the theory prediction, radiative corrections need …

    adelaide Repository record for Hadron structure in electroweak precision measurements. (opens in a new tab)

  2. Precision measurements of tau lepton decays

    … \pm 0.035)\times10^{−1}$ is measured enabling a precision test of the Standard Model assumption of charged current lepton universality, $g_{\mu}/g_{e}=1.0036 \pm 0.0020$. The branching ratios $B(\tau^- \to K^-\nu_\tau)/B(\tau^- \to e^-\nu_\tau\bar{\nu}_e)=(3.882 \pm 0.032 \pm …

    uvic Repository record for Precision measurements of tau lepton decays (opens in a new tab)

  3. Precision measurements in 20f beta decay

    … a half-life measurement was done. Previous measurements were inconsistent. The half-life was measured as 11:0011 0:0069stat 0:0030sys s. This is the most precise measurement of the half-life of 20F, and is 17 standard deviations away from the previously adopted value. This result has been …

    msu Repository record for Precision measurements in 20f beta decay (opens in a new tab)

  4. Steps Toward Precision Measurements on Molecular Ions

    … This instrumentation will facilitate precision measurements on ions and molecular ions.

    clemson Repository record for Steps Toward Precision Measurements on Molecular Ions (opens in a new tab)

  5. Precision Measurements of Blazar Spectra with VERITAS

    … of IACTs is necessary for producing accurate measurements. This thesis presents an analysis technique developed to characterize VERITAS systematics at TeV energies on blazar spectra arising from saturation of the electronics. The application of this analysis method to two epochs of data from …

    iastate Repository record for Precision Measurements of Blazar Spectra with VERITAS (opens in a new tab)

  6. Precision measurements on a single trapped beryllium ion

    Precision laser spectroscopy of transitions in simple atoms can be used as a stringent test of many-body quantum electrodynamics (QED) calculations, or to extract subtle information about internal nuclear structure. 9Be+ is a three electron ion which has been the focus of study in ion trap and high …

    colostate Repository record for Precision measurements on a single trapped beryllium ion (opens in a new tab)

  7. Precision Measurements of Magnetic Penetration Depth in Precision Measurements of Magnetic Penetration Depth in YB[sub a]₂Cu₃0₇₋[sub δ]

    … techniques, we have performed extensive measurements of the microwave surface impedance of high quality single crystals of YB[sub a]₂Cu₃0₇₋[sub δ]. We have employed a novel loop-gap resonator with operating frequency at about 1 GHz and quality factor of 1 x 10⁶ to 4 x 10⁶ to probe the …

    ubc Repository record for Precision Measurements of Magnetic Penetration Depth in Precision Measurements of Magnetic Penetration Depth in YB[sub a]₂Cu₃0₇₋[sub δ] (opens in a new tab) Download PDF for Precision Measurements of Magnetic Penetration Depth in Precision Measurements of Magnetic Penetration Depth in YB[sub a]₂Cu₃0₇₋[sub δ] (opens in a new tab)

  8. SMARTPHONE HEAD AND EYE TRACKING FOR HIGH-PRECISION MEASUREMENTS

    … is to establish the markers of accuracy and precision of the app's head and eye movement recordings. We demonstrate how accurate the application recordings are in a controlled lab setting. The third contribution is the evaluation of measured induced nystagmus in healthy participants and …

    jhu Repository record for SMARTPHONE HEAD AND EYE TRACKING FOR HIGH-PRECISION MEASUREMENTS (opens in a new tab) Embargoed until 2028-08-01

  9. Towards Precision Measurements of the Hyperfine Splitting of Antihydrogen

    … based at CERN. Through detailed observations and measurements of the antihydrogen atom structure, we can draw comparisons with the well-known structure of the hydrogen atom and search for possible asymmetries between matter and antimatter. The hyperfine structure of antihydrogen is both sensitive …

    calgary Repository record for Towards Precision Measurements of the Hyperfine Splitting of Antihydrogen (opens in a new tab)

  10. Precision measurements of the proton and deuteron polarized structure functions

    Experiment E155 at the Stanford Linear Accelerator Center measured the longitudinal and transverse polarized deep-inelastic scattering asymmetries for the proton and deuteron using longitudinally-polarized electron beams with energies of 48.3 GeV and 38.8 GeV, respectively. The electron beam …

    wm-mary Repository record for Precision measurements of the proton and deuteron polarized structure functions (opens in a new tab)

  11. Theoretical studies at the interface of atomic physics and precision measurements

    … nucleus was reported from HFS measurements in neutral ${}^{173}\mathrm{Yb}$ [PRA 87, 012512 (2013)], and is four orders of magnitude larger than the nuclear theory prediction. Considering this substantial discrepancy between the spectroscopically extracted value and nuclear …

    unr Repository record for Theoretical studies at the interface of atomic physics and precision measurements (opens in a new tab)

  12. HIGHLY-CHARGED IONS ISOLATED IN UNITARY PENNING TRAPS FOR PRECISION MEASUREMENTS

    Recently, highly--charged ions have been isolated in a novel compact Penning trap designed to capture ions extracted from the NIST electron beam ion trap (EBIT), opening a new avenue of manipulating ions isolated in a controlled environment for a variety of studies. The unique architecture of this …

    maryland Repository record for HIGHLY-CHARGED IONS ISOLATED IN UNITARY PENNING TRAPS FOR PRECISION MEASUREMENTS (opens in a new tab)

  13. Microwave effective linewidth in polycrystalline ferrites: precision measurements and new interpretations

    Experimental investigations have been made to resolve the origins and intrinsic limits of microwave loss in polycrystalline bulk ferrites through the enhanced technology and theory. First, the measurement accuracy has been improved ten-fold relative to previous data through the use of a high …

    colostate Repository record for Microwave effective linewidth in polycrystalline ferrites: precision measurements and new interpretations (opens in a new tab)

  14. PRECISION MEASUREMENTS OF THE NEUTRON ELECTRIC FORM FACTOR AT HIGH MOMENTUM TRANSFERS

    The neutron, although electrically neutral, is composed of elementary charged particles and as a result, possesses a charge distribution within. The charge distribution can be studied by measuring a quantity called the neutron electric form factor, GnE. Experiment E02-013 at Jefferson Lab’s Hall A …

    uky-thes Repository record for PRECISION MEASUREMENTS OF THE NEUTRON ELECTRIC FORM FACTOR AT HIGH MOMENTUM TRANSFERS (opens in a new tab)

  15. Manipulation and quantum control of ultracold atoms and molecules for precision measurements

    … at developing techniques for the next generation precision measurement experiments to search for a permanent electric dipole moment (EDM) of an atom or molecule. In the first experiment, we manipulate the 133Cs 6S1/2(F=4) atomic spin states with a transverse magnetic field. State-selective …

    texas Repository record for Manipulation and quantum control of ultracold atoms and molecules for precision measurements (opens in a new tab) Restricted access

  16. High-Precision Measurements of the Superallowed Beta+ Decays of 38Ca and 46V

    … Our result for the half-life of ³⁸Ca, with a precision of 0.08%, is a factor of five improvement on the best previous result. The branching-ratio of ³⁸Ca depended on beta-delayed gamma-ray intensities being measured with a high-purity germanium detector calibrated for absolute efficiency to …

    tamu Repository record for High-Precision Measurements of the Superallowed Beta+ Decays of 38Ca and 46V (opens in a new tab)

Page 1 of 16