Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"Preconcentrate"”.

  1. Evaluation of Rare Earth Element Hydraulic Preconcentrate Material Characteristics and Instrumentation Design

    … Evaluation of Rare Earth Element Hydraulic Preconcentrate Material Characteristics and Instrumentation Design Michael King Manufacturing rare earth element (REE) hydraulic preconcentrate (HPC) by the West Virginia University Water Resources Institute (WRI) requires dewatering of high-water …

    wvu Repository record for Evaluation of Rare Earth Element Hydraulic Preconcentrate Material Characteristics and Instrumentation Design (opens in a new tab)

  2. Formation and Interrogation of a Modeling Excel Database for Sorbent Preconcentrate with GC/MS

    … using sorbents in thermal desorption tubes as preconcentrates prior to analysis, commonly gas chromatography mass spectroscopy (GCMS). There are gaps in knowledge in behavior of materials used as sorbents i.e., if they will retain an analyte of interest appropriately. In this research I seek to …

    unm Repository record for Formation and Interrogation of a Modeling Excel Database for Sorbent Preconcentrate with GC/MS (opens in a new tab)

  3. Performance and Field Testing of Geotextiles for dewatering Rare Earth Element Hydraulic Preconcentrate from Hardrock AMD

    … Earth Elements (REE) supply chain the Hydraulic Preconcentrate (HPC) produced at the Horseshoe bend treatment plant (HsB) was manufactured and evaluated as a potential source for feedstock. After the existing clarifiers on the site were flipped to the desired pH set points, HPC was manufactured …

    wvu Repository record for Performance and Field Testing of Geotextiles for dewatering Rare Earth Element Hydraulic Preconcentrate from Hardrock AMD (opens in a new tab)

  4. Geotextile Filtration and Dewatering Characteristics of Acid Mine Drainage and Rare Earth Element Hydraulic Preconcentrate Precipitates

    … Mine Drainage and Rare Earth Element Hydraulic Preconcentrate Precipitates Zachary Houde Conventional active Acid Mine Drainage (AMD) treatment methods and manufacturing of Rare Earth Element (REE) Hydraulic Preconcentrate (HPC) precipitate were investigated to identify the particulate …

    wvu Repository record for Geotextile Filtration and Dewatering Characteristics of Acid Mine Drainage and Rare Earth Element Hydraulic Preconcentrate Precipitates (opens in a new tab)

  5. Evaluation of Rare Earth Element Hydraulic Preconcentrate Material Strength Characteristics and Operation Manual Development for Triaxial Machine Testing

    … Earth Elements (REE) supply chain, Hydraulic Preconcentrate (HPC) generated at the Horseshoe Bend (HsB) treatment plant was produced and evaluated as a potential feedstock source. Following adjustment of the site’s clarifiers to the required pH set points, HPC was collected and pumped into 24 …

    wvu Repository record for Evaluation of Rare Earth Element Hydraulic Preconcentrate Material Strength Characteristics and Operation Manual Development for Triaxial Machine Testing (opens in a new tab)

  6. Analysis and Field Demonstration of a Mobile Dewatering Cell for Acid Mine Drainage and Rare Earth Element Hydraulic Preconcentrate

    … of the cell. The cell was tested using hydraulic preconcentrate (HPC) from an active AMD treatment plant located in the Morgantown, WV area. HPC is a sludge-like material that comes from a two-stage treatment process of acid mine drainage, and it contains various rare earth elements. The cell was …

    wvu Repository record for Analysis and Field Demonstration of a Mobile Dewatering Cell for Acid Mine Drainage and Rare Earth Element Hydraulic Preconcentrate (opens in a new tab)

  7. Isotachophoresis in Paper-Based Microfluidic Devices

    … dissertation isotachophoresis (ITP) is used to preconcentrate and separate analytes on paper substrate in the goal to improve detection limits of paper based microfluidic devices. ITP is an effective and robust electrokinetic technique which has the potential to simultaneously preconcentrate and …

    washington Repository record for Isotachophoresis in Paper-Based Microfluidic Devices (opens in a new tab)

  8. Production of High-Grade Mixed Rare Earth Oxides from Acid Mine Drainage via Solvent Extraction: Laboratory-Scale Process Development

    … members of the research team showed that a solid preconcentrate, nominally 0.1 to 2% REE, can be readily produced from AMD; however, that pre-concentration process cannot provide the further enrichment needed to generate high purity oxides suitable for downstream markets. In this project, solvent …

    vt Repository record for Production of High-Grade Mixed Rare Earth Oxides from Acid Mine Drainage via Solvent Extraction: Laboratory-Scale Process Development (opens in a new tab)

  9. Nucleic acid sample preparation using magnetic ionic liquids as cell lysis and DNA extraction solvents

    … were investigated as DNA extraction solvents to preconcentrate nucleic acids from complex matrices such as plasma, blood, and artificial sputum. The DNA-enriched MIL was collected on a rod magnet and directly integrated into quantitative PCR (qPCR) and multiplex-qPCR assays with SYBR green and …

    iastate Repository record for Nucleic acid sample preparation using magnetic ionic liquids as cell lysis and DNA extraction solvents (opens in a new tab)

  10. Radial analyte concentration in microfluidics with an integrated planar nanoporous film

    … of target species. This necessitates the need to preconcentrate samples prior to the sensing step. The exclusion-enrichment phenomenon associated with concentration polarization has been used within microfluidic platforms for the purpose of analyte concentration though methods have all been …

    uvic Repository record for Radial analyte concentration in microfluidics with an integrated planar nanoporous film (opens in a new tab)

  11. Phosphinimines as potential technetium environmental sensors

    … are time consuming and tedious. A method to preconcentrate and measure ⁹⁹Tc environmental contamination in a quick and efficient manner is needed. The selectivity of the phosphiniminium cation for TcO₄- may make phosphinimines suitable for such preconcentration and possibly for measurement. …

    missouri Repository record for Phosphinimines as potential technetium environmental sensors (opens in a new tab)

  12. New Optical and Electrochemical Probes for Trace Chemicals with Health and Environmental Impacts

    … layer has been developed to preconcentrate hexavalent chromium [Cr(VI)] anions for analysis by cathodic stripping voltammetry (CSV). The gold electrodes were modified through chemical deposition of a thiol sol-gel layer on the electrode surface, followed by the incorporation …

    utk-theses Repository record for New Optical and Electrochemical Probes for Trace Chemicals with Health and Environmental Impacts (opens in a new tab)

  13. The extraction and analysis of dissolved trace metals from seawater using on-line flow injection inductively coupled mass spectrometry

    … with 8-hydroxyquinoline on silica resin to preconcentrate up to 18 millilitres of seawater for a minimum sample throughput of six per hour. Concentrations of these elements ranged between 0.01 and 12 nmol/kg, with analytical precision being better than 12 % for all elements except Cu, and …

    ubc Repository record for The extraction and analysis of dissolved trace metals from seawater using on-line flow injection inductively coupled mass spectrometry (opens in a new tab) Download PDF for The extraction and analysis of dissolved trace metals from seawater using on-line flow injection inductively coupled mass spectrometry (opens in a new tab)

  14. Sessile Droplet Microfluidic Platforms for Improvements in Mass Spectrometry Sample Preparation

    … with no further steps. The means to preconcentrate sessile droplets on open surfaces serves as an attractive option to improve the sample preparation and detection sensitivity for various mass spectrometry-based analytical techniques. Preliminary results show a significant increase …

    queens Repository record for Sessile Droplet Microfluidic Platforms for Improvements in Mass Spectrometry Sample Preparation (opens in a new tab)

  15. Development of Leaching Processes for the Recovery of Rare Earth Elements from Acid Mine Drainage Precipitates

    … REEs from AMD which produces rare earth oxide preconcentrate (REOP) from AMD treatment precipitates and a final stage mixed rare earth oxide (MREO) product. This body of research examines a selective leaching process for each of these products and determines the activation energy associated …

    vt Repository record for Development of Leaching Processes for the Recovery of Rare Earth Elements from Acid Mine Drainage Precipitates (opens in a new tab)

  16. Novel strategies and techniques for performing elemental speciation.

    … either acidic alumina or sulphydryl cotton to preconcentrate and separate selenium(IV) and selenium(VI) species is reported. The microcolumns were incorporated into flow analysis systems using inductively coupled plasma-mass spectrometry (ICP-MS) for detection of the selenium-82 isotope. With …

    sheffield-hallam Download PDF for Novel strategies and techniques for performing elemental speciation. (opens in a new tab)

  17. Study of hexacyanoferrate(II) nanodiamond adsorbent for the preconcentration of cesium and size categorization of radiocesium particles from contaminated soil

    … a hexacyanoferrate(II) nanodiamond adsorbent to preconcentrate dissolved Cs in contaminated solutions in order to improve the counting efficiency and accuracy for low activity samples. Also, the determination of the size of particle attached radiocesium from previous soil samples that have …

    colostate Repository record for Study of hexacyanoferrate(II) nanodiamond adsorbent for the preconcentration of cesium and size categorization of radiocesium particles from contaminated soil (opens in a new tab)

  18. Atmospheric Impact of Biogenic Volatile Organic Compounds: Improving Measurement and Modeling Capabilities

    … inlet that uses selective permeation to preconcentrate reactive organic gases in small sample flows for atmospheric gas sampling, enhancing the sensitivity and detection limits of analytical instruments. Enrichments between 4640% and 111% were measured for major reactive atmospheric gases …

    vt Repository record for Atmospheric Impact of Biogenic Volatile Organic Compounds: Improving Measurement and Modeling Capabilities (opens in a new tab)

  19. Tailoring Polymer Micro-extraction Phases to Enhance the Sensitivity and Selectivity of Raman Spectroscopy

    … like polydimethylsiloxane (PDMS) to extract and preconcentrate non-polar target analyte in headspace analysis. SPME not only enhances detection by pre-concentration of analytes, but when combined with Raman spectroscopy, offers an opportunity to reduce interference from the background by …

    washington Repository record for Tailoring Polymer Micro-extraction Phases to Enhance the Sensitivity and Selectivity of Raman Spectroscopy (opens in a new tab)

Page 1 of 3