Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 58 for “"Press fit"”.

  1. Beeinflussung der Verankerungsstabilität von Press-fit Pfannen durch die Rückflächenkonfiguration

    … ist der Vergleich der Verankerungsstabilität von Press-fit Pfannen und einer Press-fit Pfanne, welche mit sechs zusätzlichen radial angeordneten und gebogenen Finnen ausgestattet ist. Methode: Die 4 Pfannentypen (Ana.Nova® Pfanne [Fa. ImplanTec], Allofit® [Fa. Zimmer], Reflection® [Fa. …

    fu-berlin Repository record for Beeinflussung der Verankerungsstabilität von Press-fit Pfannen durch die Rückflächenkonfiguration (opens in a new tab)

  2. Evaluation of a press-fit osteochondral poly(ester-urethane) scaffold in a rabbit defect model

    … evaluate the impact on osteochondral healing of press-fitted multiphasic osteochondral scaffolds consisting of poly(ester-urethane) and hydroxyapatite into a cylindric osteochondral defect in the distal non-weight bearing femoral trochlear ridge of the rabbit. Two scaffolds were investigated, one …

    zurich Repository record for Evaluation of a press-fit osteochondral poly(ester-urethane) scaffold in a rabbit defect model (opens in a new tab)

  3. Proximal bone levels of plateau-designed, press fit implants adjacent to a natural teeth and implants.

    … bone levels of a single tooth, plateau-designed, press fit implants (Bicon®) utilizing a locking tapered, implant to abutment connection adjacent to a natural teeth and to a plateau design Bicon® implants. The bone levels were evaluated separately for those implants that were closer to a natural …

    umn Repository record for Proximal bone levels of plateau-designed, press fit implants adjacent to a natural teeth and implants. (opens in a new tab)

  4. Use of a Press-Fit Grip Sleeve for Cable-In-Conduit Superconductor Integration: Effects of Tensile and Fatigue Loading

    … of pulling toroidal field cable with a press-fit grip sleeve that utilizes friction to generate a gripping force. Such a design is being considered by ITER to integrate (join) 800 m long sections of superconducting cable and conduit for use in toroidal field plasma confinement coil …

    ut-knoxville Repository record for Use of a Press-Fit Grip Sleeve for Cable-In-Conduit Superconductor Integration: Effects of Tensile and Fatigue Loading (opens in a new tab)

  5. Investigation of the effect of surgical factors on the transition from primary to secondary stability of press-fit components in the proximal medial tibia

    … Knee Replacement (OUKR) is achieved through press-fit. It is a prerequisite for successful secondary stability and is crucial for successful long-term implant survival. The aetiology of tibial periprosthetic fracture (PPF) and tibial component subsidence which are two complications after OUKR …

    oxford Repository record for Investigation of the effect of surgical factors on the transition from primary to secondary stability of press-fit components in the proximal medial tibia (opens in a new tab)

  6. Time-dependent circumferential deformation of cortical bone subjected to internal radial loading

    … and has implications to the stability of a press-fit hip implant. Total hip arthroplasty is a surgical procedure to replace the hip joint. It involves inserting an implant into the shaft of the femur. One method of implant fixation is a press-fit of the implant into the bone canal. Press-fit …

    wvu Repository record for Time-dependent circumferential deformation of cortical bone subjected to internal radial loading (opens in a new tab)

  7. Interrupted shaft fits

    … shafts and components often use interference fits for assembly. Designers use straight and tapered fits. Coupling hubs are a good example. This thesis shows derivations relating press fit force, interference, length, taper, and friction. For simple fits, the Lamé' thick-walled cylinder …

    iastate Repository record for Interrupted shaft fits (opens in a new tab)

  8. Retrograde Ausdrückversuche am bovinen Femurkondylus zur Testung der Implantatverankerung spongiöser Konstrukte

    … <br>Das Verfahren der Wahl ist die sogenannte Press-fit Methode. Mittels Press-fit wurden spongiöse Konstrukte verschiedenen Durchmessers und Form in bovinen Femurkondylen verankert und anschliessend deren mechanische Belastbarkeit durch Ausdrückversuche verifiziert. <br>Anschliessend erfolgte …

    freiburg-diss Repository record for Retrograde Ausdrückversuche am bovinen Femurkondylus zur Testung der Implantatverankerung spongiöser Konstrukte (opens in a new tab)

  9. Primärstabilität dentaler Implantate

    … Es wurde mit 2 verschiedene Implantatsysteme (press fit-Implantate und Schraubenimplantate) der Fa. Friadent mit gleicher Länge (13 mm) jedoch unterschiedlichen Implantatdurchmessern (3,8 mm, 4,5 mm und 5,5 mm) getestet. Ziel der Untersuchung war es einen Grenzwert für die Primärstabilität …

    fu-berlin Repository record for Primärstabilität dentaler Implantate (opens in a new tab)

  10. The numerical evaluation of multi-piece crankshafts

    … Various simulation models that include press-fit joint contact conditions and complex meshing schemes are examined in order to accurately capture details of the stress fields present at the stress concentration area (labeled as the SCA) on the edge of the press-fit. The maximum stress …

    sask Repository record for The numerical evaluation of multi-piece crankshafts (opens in a new tab)

  11. The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis.

    … evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ > 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% …

    wvu Repository record for The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis. (opens in a new tab)

  12. Optical Fiber Microstructures for Self-Contained Whispering Gallery Mode Excitation

    … the fabrication and function of three new "press fit" spherical resonators. These etched fiber micro-devices were developed to meet the demand for a robust, self-integrated means of coupling light between an optical fiber and WGMs in a microsphere resonator. The etching processes have been …

    vt Repository record for Optical Fiber Microstructures for Self-Contained Whispering Gallery Mode Excitation (opens in a new tab)

  13. Development of a nano-satellite micro-coupling mechanism with characterization of a shape memory alloy interference joint

    … memory alloy (SMA) cylindrical ring that is press-fit, in its detwinned martensitic phase, into a steel bushing, creating an interference joint. This SMA interference joint can subsequently decouple upon command, by heating the SMA cylindrical ring into its smaller austenitic memory shape, …

    nps Repository record for Development of a nano-satellite micro-coupling mechanism with characterization of a shape memory alloy interference joint (opens in a new tab)

  14. Development, integration, and testing of a nano-satellite coupling mechanism using shape memory alloy for an interference joint

    … and uses a shape memory alloy (SMA) ring, press-fit into a metallic bushing to create a releasable interference joint. A detailed explanation of the techniques used to press-fit the SMA ring into the metallic bushing is included along with a description of why the SMA ring shrinks to its …

    nps Repository record for Development, integration, and testing of a nano-satellite coupling mechanism using shape memory alloy for an interference joint (opens in a new tab)

  15. Primary Fixation and Anchorage of Dental Implants in Bone Surrogate

    … of dental implants: thread mechanics and press-fit established by tapered body. Therefore, the objective of this research was to comprehensively investigate effects of implant design such as tapered body on anchorage and primary fixation of dental implants in PU foam combining mechanical …

    queens Repository record for Primary Fixation and Anchorage of Dental Implants in Bone Surrogate (opens in a new tab)

  16. Der Einfluss verschiedener Oberflächenbeschichtungen auf die Integration von Keramikimplantaten in den trabekulären Knochen des Schafs - Biomechanische Evaluation

    … Oberfläche (47 %, 200-500 µm Porengröße) mittels Press-Fit-Technik in den trabekulären Knochen des proximalen und distalen linken Humerus sowie beider Femurkondylen implantiert. Untersucht wurden eine kovalent gebundene Molekülschicht aus Phosphat-ähnlichen Gruppen (CM), eine submikrone …

    fu-berlin Repository record for Der Einfluss verschiedener Oberflächenbeschichtungen auf die Integration von Keramikimplantaten in den trabekulären Knochen des Schafs - Biomechanische Evaluation (opens in a new tab)

  17. Untersuchungen zur Rotationsstabilität des Kniegelenkes nach vorderer Kreuzbandersatzplastik mit Patellarsehne in Pressfit Technik und anatomischer Positionierung

    … Drittel der Patellarsehne in implantatfreier Press-Fit-Technik durchgeführt. Das Transplantat wurde anatomisch positioniert, femoral mit der Quadrantenmethode und tibial mit dem Impingementtest kontrolliert. Die Knochenblöcke wurden so ausgerichtet, dass eine annähernde Rekonstruktion der …

    fu-berlin Repository record for Untersuchungen zur Rotationsstabilität des Kniegelenkes nach vorderer Kreuzbandersatzplastik mit Patellarsehne in Pressfit Technik und anatomischer Positionierung (opens in a new tab)

  18. Modifikace uložení klik na jízdním kole

    … nejstaršího klínkového, až po nejmodernější typu press-fit. V praktické části byly navrženy kliky jízdního kola s ohledem na informace získané rešerší. Velký důraz byl kladen na volbu vhodného středového složení pro rekreační cyklistiku. Bylo provedeno dimenzování klik a následně popsána jejich …

    brno-tech Repository record for Modifikace uložení klik na jízdním kole (opens in a new tab)

Page 1 of 3